Skip to main content
Grant Estimator

Panasonic FV-0511VKS3 Exhaust Fan Specifications

ENERGY STAR PD #4682898 · Bathroom/Utility Room · Qualified 2026-08-05
Verified Specification Summary

Homeowners specifying Panasonic FV-0511VKS3 gain 110 CFM at 0.1 in. w.g. (111.4 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 11.4 CFM/W efficacy, venting bathrooms up to 111 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VKS3 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 111.4 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
11.4 CFM/W (#115/1,145)
Static Retention
101.3% @ 0.25"
Motor Draw
9.6 W (3.5 kWh/yr)
Duct & Tier
4 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-0511VKS3 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0511VKS3 (EPA filing PD #4682898) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 111.4 CFM out of 110 CFM (101.3% retention, 13.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #4682898 verifies FV-0511VKS3 (series: Whisper Green Select) under Panasonic (92 listed models, qualified 2026-08-05). Lighting kit: No. At 11.4 CFM/W (#115 of 1,145, top 10.7% of 1,145 rated models, more efficient than 89.3% of rated models, 6.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.6 watts, about 3.5 kWh/yr (~$0.56/yr at $0.16/kWh) for 1 hr/day shower timers or 84.1 kWh/yr (~$13.46/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Revent RVL110 (110.0 CFM).

Which exterior damper path suits Panasonic FV-0511VKS3 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Panasonic FV-0511VKS3 housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Panasonic FV-0511VKS3 acoustic and static metrics stand?

Compare Panasonic FV-0511VKS3 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-0511VKS3 / Whisper Green Select PD ID 4682898 (Qualified 2026-08-05)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (111.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Panasonic FV-0511VKS3 handle taller ceilings or walk-in tub steam?

Evaluate how Panasonic FV-0511VKS3 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0511VKS3
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 111 sq ft1 CFM/sq ft @ 111.4 CFM
Tall Bath (9-ft Ceiling)Up to 99 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 61 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.5 kWh/yr (~$0.56/yr)9.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.284.1 kWh/yr (~$13.46/yr)9.6 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Panasonic FV-0511VKS3?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
DewStop - Breeze Easy BEL110 110 / 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter

Is Panasonic FV-0511VKS3 sized right for your shower or tub room?

Check whether Panasonic FV-0511VKS3 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Where should contractors skip Panasonic FV-0511VKS3 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Panasonic FV-0511VKS3 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 61 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Choose this if: Moisture load fits 111.4 CFM net static output
  • Works well for: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Panasonic FV-0511VKS3?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Panasonic FV-0511VKS3.

Will long attic ducting choke Panasonic FV-0511VKS3 capacity?

Because static drag at 0.25 in. w.g. lowers Panasonic FV-0511VKS3 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Panasonic FV-0511VKS3 compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Panasonic FV-0511VKS3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Panasonic FV-0511VKS3 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Panasonic FV-0511VKS3 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Panasonic FV-0511VKS3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VKS3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-0511VKS3?

Panasonic FV-0511VKS3 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-0511VKS3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VKS3's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Panasonic FV-0511VKS3 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0511VKS3 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Panasonic FV-0511VKS3?

Rule out Panasonic FV-0511VKS3 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories