Skip to main content
Grant Estimator

Belanger SOU79 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · LAVATORY FAUCET 8", MG 2 LEVER HANDLES W PRESTO (1 SKU)
Verified Specification Summary

Operating at 1.0 gpm, the Belanger SOU79 faucet beats 1992 EPAct rules (2.2 gpm) by 54.5% (#3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets), saving a 3-resident home ~7,665 gallons annually compared to 2.75 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for Belanger SOU79 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.0 gpm
vs. EPAct 1992
-54.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,460 gal/yr
Annual Saved vs. Legacy
2,555 gal/person
Brand EPA Count
70 faucets
Series / Variants
SOU79 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Belanger SOU79 Benchmark & Water Budget show?

WaterSense benchmark: Belanger series SOU79 (LAVATORY FAUCET 8", MG 2 LEVER HANDLES W PRESTO) verifies 1.0 gpm delivery, scoring 54.5% leaner than EPAct 1992 (2.2 gpm) at #3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets (0.20 gpm lower-flow than the 1.20 gpm median).

Pair this 1.0 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Belanger holds 70 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~7,665 gallons/yr—roughly $61/yr in low-tariff towns ($8/1k gal), $84/yr at national averages ($11/1k gal), or $138/yr in high-rate cities ($18/1k gal). Regional utilities such as Big Bear Lake Department of Water and Power (CA) list active rebates among 200 U.S. programs. Closest alternatives: allen + roth QFS6A0229 (1.0 gpm) and Chicago Faucet E80-A11E-16ABCP (1.0 gpm).

How much leaner is Belanger SOU79 than pre-1994 2.75 gpm plumbing?

Flow distribution bars contrast Belanger SOU79 (1.00 gpm) directly with the 1.2 gpm WaterSense median and 2.75 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): SOU79: 1.00; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)SOU79: 1.00SOU791.00EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.0 gpm: 1 gpm (8th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.0 gpm: 1 gpm (P8)

Which framing and flange tolerances matter before installing Belanger SOU79?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does Belanger SOU79 compare to WaterSense category caps?

Each specification row below documents Belanger SOU79 tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Belanger (70 certified) EPA WaterSense Partner
Model Number / Series SOU79 LAVATORY FAUCET 8", MG 2 LEVER HANDLES W PRESTO (1 finish variants)
Rated Consumption 1.0 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How many gallons per year does Belanger SOU79 cut?

Calculated annual water budgets below quantify Belanger SOU79 savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for Belanger SOU79 (1.0 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,460 gal1,752 gal2,555 gal (~$28)
2 Occupants2,920 gal3,504 gal5,110 gal (~$56)
3 Occupants4,380 gal5,256 gal7,665 gal (~$61–$138)
4 Occupants5,840 gal7,008 gal10,220 gal (~$112)

Which competing models share Belanger SOU79 flow tier?

Review five peer WaterSense units matching Belanger SOU79 conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen + roth QFS6A0229 1.0 gpm (Same flow) VEDA
Chicago Faucet E80-A11E-16ABCP 1.0 gpm (Same flow) WaterSense
Conservation Management Systems 50664xx 1.0 gpm (Same flow) WaterSense
Delta 24T2a7b 1.0 gpm (Same flow) WaterSense
Delta 27T5a7b 1.0 gpm (Same flow) WaterSense

Can you estimate Belanger SOU79 payback in your home?

Test how many gallons and dollars Belanger SOU79 saves each year by entering your household residents and local water-sewer rate below.

Does Belanger SOU79 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Belanger SOU79 for your remodel.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Strong scenario: Upgrading 2.75 gpm fixtures for 63.6% water reduction
  • Best application: Matching Belanger SKU SOU79 certification on rebate forms

How do federal and code standards apply to Belanger SOU79?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Belanger SOU79.

What efficiency edge separates Belanger SOU79 from legacy and EPAct models?

Certified at 1.0 gpm, Belanger SOU79 achieves 54.5% savings against EPAct 1992 (2.2 gpm) and 75.0% savings against 4.0 gpm fixtures, 8,760 gallons per occupant yearly.

What supply pressure checks protect Belanger SOU79 spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.0 gpm trim.

Does Belanger SOU79 qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes Belanger SOU79 eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does Belanger SOU79 rank against other certified faucets?

Rated at 1.0 gpm, Belanger SOU79 measures below the 1.2 gpm WaterSense faucet median across thousands of EPA-listed residential fixtures.

Does Belanger SOU79 cut utility costs noticeably for a 3-person household?

Yes: cutting 26,280 gallons/yr relative to 4.0 gpm hardware translates to ~$289/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with Belanger SOU79?

Pairing Belanger SOU79 (1.0 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.0 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Belanger SOU79 require a municipal plumbing permit?

Like-for-like swaps using Belanger SOU79 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories