Skip to main content
Grant Estimator

Chicago Faucet 786-E73-319XKABCP WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · Chicago Faucet (4 SKUs)
Verified Specification Summary

Certified under EPA WaterSense, Chicago Faucet 786-E73-319XKABCP tests at 1.0 gpm (#3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets), trimming 54.5% off the 2.2 gpm federal cap while cutting 3-person household draw by ~7,665 gal/yr versus 2.75 gpm fixtures. Compare EPA WaterSense certified flow metrics for Chicago Faucet 786-E73-319XKABCP WaterSense Faucet, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.0 gpm
vs. EPAct 1992
-54.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,460 gal/yr
Annual Saved vs. Legacy
2,555 gal/person
Brand EPA Count
1,018 faucets
Series / Variants
786-E73-319XKABCP (4)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Chicago Faucet 786-E73-319XKABCP Benchmark & Water Budget show?

Efficiency check: certified at 1.0 gpm, Chicago Faucet 786-E73-319XKABCP trims 54.5% under federal 2.2 gpm caps; #3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets (0.20 gpm lower-flow than the 1.20 gpm median).

Pair this 1.0 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Chicago Faucet holds 1,018 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~7,665 gallons/yr—roughly $61/yr in low-tariff towns ($8/1k gal), $84/yr at national averages ($11/1k gal), or $138/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: allen + roth QFS6A0229 (1.0 gpm) and Belanger IND79C (1.0 gpm).

Where does Chicago Faucet 786-E73-319XKABCP sit on the EPA WaterSense faucet flow curve?

Comparing Chicago Faucet 786-E73-319XKABCP (1.00 gpm) against federal EPAct (2.2 gpm) and legacy (2.75 gpm) baselines shows immediate per-use conservation.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 786-E73-319XKABCP: 1.00; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)786-E73-319XKABCP: 1.00786-E73-319XKABCP1.00EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.0 gpm: 1 gpm (8th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.0 gpm: 1 gpm (P8)

How do subfloor levelness and rough-in height protect Chicago Faucet 786-E73-319XKABCP?

Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What official WaterSense figures verify Chicago Faucet 786-E73-319XKABCP?

Examine Chicago Faucet 786-E73-319XKABCP certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Chicago Faucet (1,018 certified) EPA WaterSense Partner
Model Number / Series 786-E73-319XKABCP Certified Series (4 finish variants)
Rated Consumption 1.0 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 4 finish and trim SKUs share the Chicago Faucet 786-E73-319XKABCP WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 4 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into Chicago Faucet 786-E73-319XKABCP (4 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
786-E73-319XKABCP1.0 gpmShared Series Spec
786-E73-369XKABCP1.0 gpmShared Series Spec
786-E73-245ABCP1.0 gpmShared Series Spec
786-E73-319ABCP1.0 gpmShared Series Spec

What annual utility savings does Chicago Faucet 786-E73-319XKABCP deliver?

Compare 1-to-4-person household water use with Chicago Faucet 786-E73-319XKABCP against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.

Computed annual water savings for Chicago Faucet 786-E73-319XKABCP (1.0 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,460 gal1,752 gal2,555 gal (~$28)
2 Occupants2,920 gal3,504 gal5,110 gal (~$56)
3 Occupants4,380 gal5,256 gal7,665 gal (~$61–$138)
4 Occupants5,840 gal7,008 gal10,220 gal (~$112)

What alternative WaterSense models compare to Chicago Faucet 786-E73-319XKABCP?

Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen + roth QFS6A0229 1.0 gpm (Same flow) VEDA
Belanger IND79C 1.0 gpm (Same flow) WaterSense
Conservation Management Systems 50664xx 1.0 gpm (Same flow) WaterSense
Delta 24T2a7b 1.0 gpm (Same flow) WaterSense
Delta 27T5a7b 1.0 gpm (Same flow) WaterSense

What will Chicago Faucet 786-E73-319XKABCP save on your annual water bill?

Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.

Which bath layouts should avoid specifying Chicago Faucet 786-E73-319XKABCP?

Match Chicago Faucet 786-E73-319XKABCP directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Existing shower valve lacks ASSE 1016 pressure balancing

Best-Fit Homeowner Profiles

  • Best for: Meeting 2.2 gpm federal & stricter WaterSense caps
  • Optimal use: Targeting ~$84/yr utility savings (3-person home)

Which homeowner questions come up most for Chicago Faucet 786-E73-319XKABCP?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Chicago Faucet 786-E73-319XKABCP.

Where does Chicago Faucet 786-E73-319XKABCP rank against other certified faucets?

Rated at 1.0 gpm, Chicago Faucet 786-E73-319XKABCP measures below the 1.2 gpm WaterSense faucet median across thousands of EPA-listed residential fixtures.

Does Chicago Faucet 786-E73-319XKABCP cut utility costs noticeably for a 3-person household?

Yes: cutting 26,280 gallons/yr relative to 4.0 gpm hardware translates to ~$289/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with Chicago Faucet 786-E73-319XKABCP?

Pairing Chicago Faucet 786-E73-319XKABCP (1.0 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.0 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Chicago Faucet 786-E73-319XKABCP require a municipal plumbing permit?

Like-for-like swaps using Chicago Faucet 786-E73-319XKABCP on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How does Chicago Faucet 786-E73-319XKABCP cut household water draw versus 1992 federal rules?

Delivering 1.0 gpm, Chicago Faucet 786-E73-319XKABCP trims 3,504 gal/person/yr below 2.2 gpm EPAct caps (54.5% reduction) and 8,760 gal/person/yr under 4.0 gpm legacy fixtures.

What supply pressure checks protect Chicago Faucet 786-E73-319XKABCP spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.0 gpm trim.

Does Chicago Faucet 786-E73-319XKABCP qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes Chicago Faucet 786-E73-319XKABCP eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories