Skip to main content
Grant Estimator

Delta Commercial 8a0DPA2b-c WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · Delta Commercial (1 SKU)
Verified Specification Summary

Listed in EPA WaterSense files at 1.0 gpm, Delta Commercial 8a0DPA2b-c achieves #3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets and lowers household water use ~7,665 gal/yr (3 residents) against pre-1994 2.75 gpm fixtures. Compare EPA WaterSense certified flow metrics for Delta Commercial 8a0DPA2b-c WaterSense Faucet, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.0 gpm
vs. EPAct 1992
-54.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,460 gal/yr
Annual Saved vs. Legacy
2,555 gal/person
Brand EPA Count
116 faucets
Series / Variants
8a0DPA2b-c (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Delta Commercial 8a0DPA2b-c Benchmark & Water Budget show?

Certified discharge for Delta Commercial 8a0DPA2b-c measures 1.0 gpm (aggressive sub-1.6 gpm conservation tier), standing #3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets (0.20 gpm lower-flow than the 1.20 gpm median) against the 2.2 gpm standard.

Pair this 1.0 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Delta Commercial holds 116 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~7,665 gallons/yr—roughly $61/yr in low-tariff towns ($8/1k gal), $84/yr at national averages ($11/1k gal), or $138/yr in high-rate cities ($18/1k gal). Regional utilities such as Big Bear Lake Department of Water and Power (CA) list active rebates among 200 U.S. programs. Closest alternatives: allen + roth QFS6A0229 (1.0 gpm) and Belanger IND79C (1.0 gpm).

Does Delta Commercial 8a0DPA2b-c beat the 1.2 gpm WaterSense faucet median?

Certified at 1.00 gpm, Delta Commercial 8a0DPA2b-c sits well under EPAct 1992 limits (2.2 gpm) across 22,471 EPA-registered faucets.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 8a0DPA2b-c: 1.00; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)8a0DPA2b-c: 1.008a0DPA2b-c1.00EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.0 gpm: 1 gpm (8th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.0 gpm: 1 gpm (P8)

Why check closet flange height and L/360 stiffness around Delta Commercial 8a0DPA2b-c?

Checking framing deflection (L/360) and finished tile-to-flange elevation before fixture mounting eliminates wobble and concealed floor leaks.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Where does Delta Commercial 8a0DPA2b-c fit in EPA WaterSense files?

Review certified water flow, brand lineup breadth, and ASSE 1016 valve or IPC closet flange pairing guidelines for Delta Commercial 8a0DPA2b-c.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Delta Commercial (116 certified) EPA WaterSense Partner
Model Number / Series 8a0DPA2b-c Certified Series (1 finish variants)
Rated Consumption 1.0 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Does Delta Commercial 8a0DPA2b-c lower water bills for larger households?

Review computed annual water totals for 1 to 4 residents comparing Delta Commercial 8a0DPA2b-c certified consumption with older pre-1994 residential plumbing hardware.

Computed annual water savings for Delta Commercial 8a0DPA2b-c (1.0 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,460 gal1,752 gal2,555 gal (~$28)
2 Occupants2,920 gal3,504 gal5,110 gal (~$56)
3 Occupants4,380 gal5,256 gal7,665 gal (~$61–$138)
4 Occupants5,840 gal7,008 gal10,220 gal (~$112)

How do similar WaterSense brands compare with Delta Commercial 8a0DPA2b-c?

Comparable certified models listed below share Delta Commercial 8a0DPA2b-c category standards while offering alternative brand warranties and rough-in configurations.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen + roth QFS6A0229 1.0 gpm (Same flow) VEDA
Belanger IND79C 1.0 gpm (Same flow) WaterSense
Chicago Faucet E80-A11E-16ABCP 1.0 gpm (Same flow) WaterSense
Conservation Management Systems 50664xx 1.0 gpm (Same flow) WaterSense
Delta 24T2a7b 1.0 gpm (Same flow) WaterSense

How do local water rates change Delta Commercial 8a0DPA2b-c savings?

Use the local browser estimator below with your city water-sewer rate and household size to quantify Delta Commercial 8a0DPA2b-c yearly utility impact.

Who should not install Delta Commercial 8a0DPA2b-c in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Delta Commercial 8a0DPA2b-c for residential use.

Limitations & Who Should Skip

  • Low static water supply pressure <30 PSI

Best-Fit Homeowner Profiles

  • Ideal fit: Claiming utility rebates across 200 U.S. WaterSense programs
  • Primary match: Lowering household draw to 1,460 gal/person/yr

What should homeowners verify first about Delta Commercial 8a0DPA2b-c?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Delta Commercial 8a0DPA2b-c.

Who should NOT install Delta Commercial 8a0DPA2b-c without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.0 gpm faucet.

Can homeowners claim utility rebates when installing Delta Commercial 8a0DPA2b-c?

Because Delta Commercial 8a0DPA2b-c holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is Delta Commercial 8a0DPA2b-c leaner than typical WaterSense faucet models?

Compared with the 1.2 gpm WaterSense faucet median, Delta Commercial 8a0DPA2b-c's 1.0 gpm rating places it below category norms inside EPA conservation limits.

What annual dollar savings can a 3-person home expect with Delta Commercial 8a0DPA2b-c?

Upgrading a 4.0 gpm legacy fixture to Delta Commercial 8a0DPA2b-c saves ~26,280 gallons yearly for three occupants, about $289/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with Delta Commercial 8a0DPA2b-c?

Pairing Delta Commercial 8a0DPA2b-c (1.0 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.0 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Delta Commercial 8a0DPA2b-c require a municipal plumbing permit?

Like-for-like swaps using Delta Commercial 8a0DPA2b-c on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How much water does Delta Commercial 8a0DPA2b-c save compared with EPAct 1992 and pre-1994 fixtures?

Rated at 1.0 gpm, Delta Commercial 8a0DPA2b-c cuts 54.5% below the 2.2 gpm EPAct 1992 ceiling and 75.0% under 4.0 gpm legacy units, saving 8,760 gal/person/yr (3,504 vs EPAct).

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories