JM J03-10 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · JM (1 SKU)
Verified Specification Summary

Certified under EPA WaterSense, JM J03-10 tests at 1.0 gpm (#3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets), trimming 54.5% off the 2.2 gpm federal cap while cutting 3-person household draw by ~7,665 gal/yr versus 2.75 gpm fixtures. Compare EPA WaterSense certified flow metrics for JM J03-10 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.0 gpm
vs. EPAct 1992
-54.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,460 gal/yr
Annual Saved vs. Legacy
2,555 gal/person
Brand EPA Count
14 faucets
Series / Variants
J03-10 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does JM J03-10 Benchmark & Water Budget show?

Efficiency check: certified at 1.0 gpm, JM J03-10 trims 54.5% under federal 2.2 gpm caps; #3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets (0.20 gpm lower-flow than the 1.20 gpm median).

Pair this 1.0 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: JM holds 14 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~7,665 gallons/yr—roughly $61/yr in low-tariff towns ($8/1k gal), $84/yr at national averages ($11/1k gal), or $138/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: allen + roth QFS6A0229 (1.0 gpm) and Belanger IND79C (1.0 gpm).

Where does JM J03-10 sit on the EPA WaterSense faucet flow curve?

Comparing JM J03-10 (1.00 gpm) against federal EPAct (2.2 gpm) and legacy (2.75 gpm) baselines shows immediate per-use conservation.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): J03-10: 1.00; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)J03-10: 1.00J03-101.00EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.0 gpm: 1 gpm (8th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.0 gpm: 1 gpm (P8)

How do subfloor levelness and rough-in height protect JM J03-10?

Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What official WaterSense figures verify JM J03-10?

Examine JM J03-10 certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share JM (14 certified) EPA WaterSense Partner
Model Number / Series J03-10 Certified Series (1 finish variants)
Rated Consumption 1.0 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

What annual utility savings does JM J03-10 deliver?

Compare 1-to-4-person household water use with JM J03-10 against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.

Computed annual water savings for JM J03-10 (1.0 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,460 gal1,752 gal2,555 gal (~$28)
2 Occupants2,920 gal3,504 gal5,110 gal (~$56)
3 Occupants4,380 gal5,256 gal7,665 gal (~$61–$138)
4 Occupants5,840 gal7,008 gal10,220 gal (~$112)

What alternative WaterSense models compare to JM J03-10?

Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen + roth QFS6A0229 1.0 gpm (Same flow) VEDA
Belanger IND79C 1.0 gpm (Same flow) WaterSense
Chicago Faucet E80-A11E-16ABCP 1.0 gpm (Same flow) WaterSense
Conservation Management Systems 50664xx 1.0 gpm (Same flow) WaterSense
Delta 24T2a7b 1.0 gpm (Same flow) WaterSense

What will JM J03-10 save on your annual water bill?

Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.

Where should contractors skip JM J03-10 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for JM J03-10 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Existing shower valve lacks ASSE 1016 pressure balancing

Best-Fit Homeowner Profiles

  • Choose this if: Meeting 2.2 gpm federal & stricter WaterSense caps
  • Works well for: Targeting ~$84/yr utility savings (3-person home)

Which homeowner questions come up most for JM J03-10?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around JM J03-10.

How many gallons per person does JM J03-10 save annually?

Each resident saves ~8,760 gallons yearly (75.0% drop) replacing a 4.0 gpm fixture with JM J03-10 (1.0 gpm), or 3,504 gal/yr versus 2.2 gpm EPAct baselines.

Who should NOT install JM J03-10 without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.0 gpm faucet.

Can homeowners claim utility rebates when installing JM J03-10?

Because JM J03-10 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is JM J03-10 leaner than typical WaterSense faucet models?

Compared with the 1.2 gpm WaterSense faucet median, JM J03-10's 1.0 gpm rating places it below category norms inside EPA conservation limits.

What annual dollar savings can a 3-person home expect with JM J03-10?

Upgrading a 4.0 gpm legacy fixture to JM J03-10 saves ~26,280 gallons yearly for three occupants, about $289/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with JM J03-10?

Pairing JM J03-10 (1.0 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.0 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing JM J03-10 require a municipal plumbing permit?

Like-for-like swaps using JM J03-10 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories