Skip to main content
Grant Estimator

LACAVA EX03A WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · ZOOM (9 SKUs)
Verified Specification Summary

Operating at 1.0 gpm, the LACAVA EX03A faucet beats 1992 EPAct rules (2.2 gpm) by 54.5% (#3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets), saving a 3-resident home ~7,665 gallons annually compared to 2.75 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for LACAVA EX03A WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.0 gpm
vs. EPAct 1992
-54.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,460 gal/yr
Annual Saved vs. Legacy
2,555 gal/person
Brand EPA Count
53 faucets
Series / Variants
EX03A (9)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does LACAVA EX03A Benchmark & Water Budget show?

WaterSense benchmark: LACAVA series EX03A (ZOOM) verifies 1.0 gpm delivery, scoring 54.5% leaner than EPAct 1992 (2.2 gpm) at #3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets (0.20 gpm lower-flow than the 1.20 gpm median).

Pair this 1.0 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: LACAVA holds 53 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~7,665 gallons/yr—roughly $61/yr in low-tariff towns ($8/1k gal), $84/yr at national averages ($11/1k gal), or $138/yr in high-rate cities ($18/1k gal). Regional utilities such as California Water Service Company (CA) list active rebates among 200 U.S. programs. Closest alternatives: allen + roth QFS6A0229 (1.0 gpm) and Belanger IND79C (1.0 gpm).

How much leaner is LACAVA EX03A than pre-1994 2.75 gpm plumbing?

Flow distribution bars contrast LACAVA EX03A (1.00 gpm) directly with the 1.2 gpm WaterSense median and 2.75 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): EX03A: 1.00; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)EX03A: 1.00EX03A1.00EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.0 gpm: 1 gpm (8th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.0 gpm: 1 gpm (P8)

Which framing and flange tolerances matter before installing LACAVA EX03A?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does LACAVA EX03A compare to WaterSense category caps?

Each specification row below documents LACAVA EX03A tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share LACAVA (53 certified) EPA WaterSense Partner
Model Number / Series EX03A ZOOM (9 finish variants)
Rated Consumption 1.0 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 9 finish and trim SKUs share the LACAVA EX03A WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 8 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into LACAVA EX03A (9 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
EX03A-*1.0 gpmZOOM
EX21-*1.0 gpmZOOM
EX24-*1.0 gpmZOOM
EX16-*1.0 gpmZOOM
EX04A-*1.0 gpmZOOM
EX11-*1.0 gpmZOOM
EX18-*1.0 gpmZOOM
EX10A-*1.0 gpmZOOM

How many gallons per year does LACAVA EX03A cut?

Calculated annual water budgets below quantify LACAVA EX03A savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for LACAVA EX03A (1.0 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,460 gal1,752 gal2,555 gal (~$28)
2 Occupants2,920 gal3,504 gal5,110 gal (~$56)
3 Occupants4,380 gal5,256 gal7,665 gal (~$61–$138)
4 Occupants5,840 gal7,008 gal10,220 gal (~$112)

Which competing models share LACAVA EX03A flow tier?

Review five peer WaterSense units matching LACAVA EX03A conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen + roth QFS6A0229 1.0 gpm (Same flow) VEDA
Belanger IND79C 1.0 gpm (Same flow) WaterSense
Chicago Faucet E80-A11E-16ABCP 1.0 gpm (Same flow) WaterSense
Conservation Management Systems 50664xx 1.0 gpm (Same flow) WaterSense
Delta 24T2a7b 1.0 gpm (Same flow) WaterSense

Can you estimate LACAVA EX03A payback in your home?

Test how many gallons and dollars LACAVA EX03A saves each year by entering your household residents and local water-sewer rate below.

Which bath layouts should avoid specifying LACAVA EX03A?

Match LACAVA EX03A directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Best for: Upgrading 2.75 gpm fixtures for 63.6% water reduction
  • Optimal use: Matching LACAVA SKU EX03A certification on rebate forms

How do federal and code standards apply to LACAVA EX03A?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for LACAVA EX03A.

Where does LACAVA EX03A rank against other certified faucets?

Rated at 1.0 gpm, LACAVA EX03A measures below the 1.2 gpm WaterSense faucet median across thousands of EPA-listed residential fixtures.

Does LACAVA EX03A cut utility costs noticeably for a 3-person household?

Yes: cutting 26,280 gallons/yr relative to 4.0 gpm hardware translates to ~$289/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with LACAVA EX03A?

Pairing LACAVA EX03A (1.0 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.0 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing LACAVA EX03A require a municipal plumbing permit?

Like-for-like swaps using LACAVA EX03A on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How does LACAVA EX03A cut household water draw versus 1992 federal rules?

Delivering 1.0 gpm, LACAVA EX03A trims 3,504 gal/person/yr below 2.2 gpm EPAct caps (54.5% reduction) and 8,760 gal/person/yr under 4.0 gpm legacy fixtures.

What supply pressure checks protect LACAVA EX03A spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.0 gpm trim.

Does LACAVA EX03A qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes LACAVA EX03A eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories