Skip to main content
Grant Estimator

Neoperl 40.2258.450 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · Neoperl (2 SKUs)
Verified Specification Summary

Verified by EPA WaterSense at 1.0 gpm, Neoperl 40.2258.450 sits 54.5% under federal 2.2 gpm ceilings (#3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets) and saves ~7,665 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for Neoperl 40.2258.450 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.0 gpm
vs. EPAct 1992
-54.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,460 gal/yr
Annual Saved vs. Legacy
2,555 gal/person
Brand EPA Count
545 faucets
Series / Variants
40.2258.450 (2)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Neoperl 40.2258.450 Benchmark & Water Budget show?

Under EPA WaterSense protocols, Neoperl 40.2258.450 delivers 1.0 gpm (#3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets (0.20 gpm lower-flow than the 1.20 gpm median)), beating the 2.2 gpm federal ceiling by 54.5%.

Pair this 1.0 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Neoperl holds 545 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~7,665 gallons/yr—roughly $61/yr in low-tariff towns ($8/1k gal), $84/yr at national averages ($11/1k gal), or $138/yr in high-rate cities ($18/1k gal). Regional utilities such as California Water Service Company (CA) list active rebates among 200 U.S. programs. Closest alternatives: allen + roth QFS6A0229 (1.0 gpm) and Belanger IND79C (1.0 gpm).

Where does Neoperl 40.2258.450 rank among 22,471 certified faucets?

Review how Neoperl 40.2258.450 (1.00 gpm) places inside EPA WaterSense's 22,471-SKU faucet registry alongside historical 2.75 gpm units.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 40.2258.450: 1.00; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)40.2258.450: 1.0040.2258.4501.00EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.0 gpm: 1 gpm (8th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.0 gpm: 1 gpm (P8)

What plumbing rough-in clearances prevent leaks around Neoperl 40.2258.450?

Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which certified attributes define Neoperl 40.2258.450 performance?

Official U.S. EPA WaterSense registry entries below confirm Neoperl 40.2258.450 rated flow rate, model series status, and household code fit.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Neoperl (545 certified) EPA WaterSense Partner
Model Number / Series 40.2258.450 Certified Series (2 finish variants)
Rated Consumption 1.0 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 2 finish and trim SKUs share the Neoperl 40.2258.450 WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 2 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into Neoperl 40.2258.450 (2 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
40.2258.4501.0 gpmShared Series Spec
40.2258.0101.0 gpmShared Series Spec

How do Neoperl 40.2258.450 savings scale from 1 to 4 occupants?

Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to Neoperl 40.2258.450 across different household sizes.

Computed annual water savings for Neoperl 40.2258.450 (1.0 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,460 gal1,752 gal2,555 gal (~$28)
2 Occupants2,920 gal3,504 gal5,110 gal (~$56)
3 Occupants4,380 gal5,256 gal7,665 gal (~$61–$138)
4 Occupants5,840 gal7,008 gal10,220 gal (~$112)

Which peer fixtures deliver flow close to Neoperl 40.2258.450?

Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen + roth QFS6A0229 1.0 gpm (Same flow) VEDA
Belanger IND79C 1.0 gpm (Same flow) WaterSense
Chicago Faucet E80-A11E-16ABCP 1.0 gpm (Same flow) WaterSense
Conservation Management Systems 50664xx 1.0 gpm (Same flow) WaterSense
Delta 24T2a7b 1.0 gpm (Same flow) WaterSense

Does Neoperl 40.2258.450 pay off faster in high-rate cities?

Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark Neoperl 40.2258.450 annual savings immediately.

What plumbing or duct constraints rule out Neoperl 40.2258.450?

Compare where Neoperl 40.2258.450 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Homeowner profile: Upgrading 2.75 gpm fixtures for 63.6% water reduction
  • Suited to: Matching Neoperl SKU 40.2258.450 certification on rebate forms

Where do official rules set limits for Neoperl 40.2258.450?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Neoperl 40.2258.450.

How does Neoperl 40.2258.450 perform relative to the EPA WaterSense category median?

Among certified WaterSense faucets, the national median stands at 1.2 gpm. At 1.0 gpm, Neoperl 40.2258.450 sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Neoperl 40.2258.450?

At $11 per 1,000 gallons, a 3-person household conserving 26,280 gallons/yr with Neoperl 40.2258.450 trims roughly $289 annually off water and sewer utility bills.

What anti-scald valve standard pairs with Neoperl 40.2258.450?

Pairing Neoperl 40.2258.450 (1.0 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.0 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Neoperl 40.2258.450 require a municipal plumbing permit?

Like-for-like swaps using Neoperl 40.2258.450 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 4.0 gpm fixture to Neoperl 40.2258.450 at 1.0 gpm?

Swapping a 4.0 gpm unit for Neoperl 40.2258.450 slashes water draw 75.0% (8,760 gal/person/yr), beating 2.2 gpm federal EPAct standards by 54.5%.

When can Neoperl 40.2258.450 (1.0 gpm) underperform in an older bathroom?

Skip Neoperl 40.2258.450 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat Neoperl 40.2258.450?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Neoperl 40.2258.450, itemized purchase invoices, and residential installation addresses.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories