NEOPERL 42.2013.000 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · PL-HC-JR-PCA-DC (2 SKUs)
Verified Specification Summary

Operating at 1.0 gpm, the NEOPERL 42.2013.000 faucet beats 1992 EPAct rules (2.2 gpm) by 54.5% (#3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets), saving a 3-resident home ~7,665 gallons annually compared to 2.75 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for NEOPERL 42.2013.000 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.0 gpm
vs. EPAct 1992
-54.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,460 gal/yr
Annual Saved vs. Legacy
2,555 gal/person
Brand EPA Count
478 faucets
Series / Variants
42.2013.000 (2)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does NEOPERL 42.2013.000 Benchmark & Water Budget show?

WaterSense benchmark: NEOPERL series 42.2013.000 (PL-HC-JR-PCA-DC) verifies 1.0 gpm delivery, scoring 54.5% leaner than EPAct 1992 (2.2 gpm) at #3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets (0.20 gpm lower-flow than the 1.20 gpm median).

Pair this 1.0 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: NEOPERL holds 478 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~7,665 gallons/yr—roughly $61/yr in low-tariff towns ($8/1k gal), $84/yr at national averages ($11/1k gal), or $138/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Tucson - Tucson Water (AZ) list active rebates among 200 U.S. programs. Closest alternatives: allen + roth QFS6A0229 (1.0 gpm) and Belanger IND79C (1.0 gpm).

How much leaner is NEOPERL 42.2013.000 than pre-1994 2.75 gpm plumbing?

Flow distribution bars contrast NEOPERL 42.2013.000 (1.00 gpm) directly with the 1.2 gpm WaterSense median and 2.75 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 42.2013.000: 1.00; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)42.2013.000: 1.0042.2013.0001.00EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.0 gpm: 1 gpm (8th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.0 gpm: 1 gpm (P8)

Which framing and flange tolerances matter before installing NEOPERL 42.2013.000?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does NEOPERL 42.2013.000 compare to WaterSense category caps?

Each specification row below documents NEOPERL 42.2013.000 tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share NEOPERL (478 certified) EPA WaterSense Partner
Model Number / Series 42.2013.000 PL-HC-JR-PCA-DC (2 finish variants)
Rated Consumption 1.0 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 2 finish and trim SKUs share the NEOPERL 42.2013.000 WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 2 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into NEOPERL 42.2013.000 (2 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
42.2013.0001.0 gpmPL-HC-JR-PCA-DC
42.3013.0001.0 gpmPL-HC-JR-PCA-DC

How many gallons per year does NEOPERL 42.2013.000 cut?

Calculated annual water budgets below quantify NEOPERL 42.2013.000 savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for NEOPERL 42.2013.000 (1.0 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,460 gal1,752 gal2,555 gal (~$28)
2 Occupants2,920 gal3,504 gal5,110 gal (~$56)
3 Occupants4,380 gal5,256 gal7,665 gal (~$61–$138)
4 Occupants5,840 gal7,008 gal10,220 gal (~$112)

Which competing models share NEOPERL 42.2013.000 flow tier?

Review five peer WaterSense units matching NEOPERL 42.2013.000 conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen + roth QFS6A0229 1.0 gpm (Same flow) VEDA
Belanger IND79C 1.0 gpm (Same flow) WaterSense
Chicago Faucet E80-A11E-16ABCP 1.0 gpm (Same flow) WaterSense
Conservation Management Systems 50664xx 1.0 gpm (Same flow) WaterSense
Delta 24T2a7b 1.0 gpm (Same flow) WaterSense

Can you estimate NEOPERL 42.2013.000 payback in your home?

Test how many gallons and dollars NEOPERL 42.2013.000 saves each year by entering your household residents and local water-sewer rate below.

Where should contractors skip NEOPERL 42.2013.000 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for NEOPERL 42.2013.000 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Choose this if: Upgrading 2.75 gpm fixtures for 63.6% water reduction
  • Works well for: Matching NEOPERL SKU 42.2013.000 certification on rebate forms

How do federal and code standards apply to NEOPERL 42.2013.000?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for NEOPERL 42.2013.000.

Who should NOT install NEOPERL 42.2013.000 without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.0 gpm faucet.

Can homeowners claim utility rebates when installing NEOPERL 42.2013.000?

Because NEOPERL 42.2013.000 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is NEOPERL 42.2013.000 leaner than typical WaterSense faucet models?

Compared with the 1.2 gpm WaterSense faucet median, NEOPERL 42.2013.000's 1.0 gpm rating places it below category norms inside EPA conservation limits.

What annual dollar savings can a 3-person home expect with NEOPERL 42.2013.000?

Upgrading a 4.0 gpm legacy fixture to NEOPERL 42.2013.000 saves ~26,280 gallons yearly for three occupants, about $289/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with NEOPERL 42.2013.000?

Pairing NEOPERL 42.2013.000 (1.0 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.0 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing NEOPERL 42.2013.000 require a municipal plumbing permit?

Like-for-like swaps using NEOPERL 42.2013.000 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How many gallons per person does NEOPERL 42.2013.000 save annually?

Each resident saves ~8,760 gallons yearly (75.0% drop) replacing a 4.0 gpm fixture with NEOPERL 42.2013.000 (1.0 gpm), or 3,504 gal/yr versus 2.2 gpm EPAct baselines.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories