Skip to main content
Grant Estimator

NEOPERL 42.2113.000 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · PL-HC-JR-PCA-DC-lam (2 SKUs)
Verified Specification Summary

The NEOPERL 42.2113.000 is an EPA WaterSense faucet certified at 1.0 gpm, 54.5% below EPAct 1992 (2.2 gpm) and #3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets. A 3-person household saves ~7,665 gallons/yr replacing a 2.75 gpm legacy fixture. Compare EPA WaterSense certified flow metrics for NEOPERL 42.2113.000 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.0 gpm
vs. EPAct 1992
-54.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,460 gal/yr
Annual Saved vs. Legacy
2,555 gal/person
Brand EPA Count
478 faucets
Series / Variants
42.2113.000 (2)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does NEOPERL 42.2113.000 Benchmark & Water Budget show?

Flow standing: NEOPERL 42.2113.000 (PL-HC-JR-PCA-DC-lam) operates at 1.0 gpm (aggressive sub-1.6 gpm conservation tier), #3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets (0.20 gpm lower-flow than the 1.20 gpm median), cutting 54.5% off EPAct 1992 (2.2 gpm).

Pair this 1.0 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: NEOPERL holds 478 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~7,665 gallons/yr—roughly $61/yr in low-tariff towns ($8/1k gal), $84/yr at national averages ($11/1k gal), or $138/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: allen + roth QFS6A0229 (1.0 gpm) and Belanger IND79C (1.0 gpm).

How does NEOPERL 42.2113.000 compare to EPAct 1992 and legacy gpm rates?

Tested at 1.00 gpm, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (2.2 gpm) and pre-1994 legacy units (2.75 gpm).

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 42.2113.000: 1.00; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)42.2113.000: 1.0042.2113.0001.00EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.0 gpm: 1 gpm (8th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.0 gpm: 1 gpm (P8)

What floor flatness and flange clearances pair with NEOPERL 42.2113.000?

Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which EPA WaterSense test specs apply to NEOPERL 42.2113.000?

Certified EPA WaterSense records for NEOPERL 42.2113.000 verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share NEOPERL (478 certified) EPA WaterSense Partner
Model Number / Series 42.2113.000 PL-HC-JR-PCA-DC-lam (2 finish variants)
Rated Consumption 1.0 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 2 finish and trim SKUs share the NEOPERL 42.2113.000 WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 2 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into NEOPERL 42.2113.000 (2 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
42.2113.0001.0 gpmPL-HC-JR-PCA-DC-lam
42.3113.0001.0 gpmPL-HC-JR-PCA-DC-lam

How much water and money can NEOPERL 42.2113.000 save each year?

Household projections below calculate NEOPERL 42.2113.000 annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.

Computed annual water savings for NEOPERL 42.2113.000 (1.0 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,460 gal1,752 gal2,555 gal (~$28)
2 Occupants2,920 gal3,504 gal5,110 gal (~$56)
3 Occupants4,380 gal5,256 gal7,665 gal (~$61–$138)
4 Occupants5,840 gal7,008 gal10,220 gal (~$112)

Which EPA WaterSense fixtures match NEOPERL 42.2113.000?

Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen + roth QFS6A0229 1.0 gpm (Same flow) VEDA
Belanger IND79C 1.0 gpm (Same flow) WaterSense
Chicago Faucet E80-A11E-16ABCP 1.0 gpm (Same flow) WaterSense
Conservation Management Systems 50664xx 1.0 gpm (Same flow) WaterSense
Delta 24T2a7b 1.0 gpm (Same flow) WaterSense

How much does NEOPERL 42.2113.000 save at your local water rate?

Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.

Where should contractors skip NEOPERL 42.2113.000 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for NEOPERL 42.2113.000 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Low static water supply pressure <30 PSI

Best-Fit Homeowner Profiles

  • Choose this if: Claiming utility rebates across 200 U.S. WaterSense programs
  • Works well for: Lowering household draw to 1,460 gal/person/yr

What key rules and numbers govern NEOPERL 42.2113.000?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting NEOPERL 42.2113.000.

Can homeowners claim utility rebates when installing NEOPERL 42.2113.000?

Because NEOPERL 42.2113.000 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is NEOPERL 42.2113.000 leaner than typical WaterSense faucet models?

Compared with the 1.2 gpm WaterSense faucet median, NEOPERL 42.2113.000's 1.0 gpm rating places it below category norms inside EPA conservation limits.

What annual dollar savings can a 3-person home expect with NEOPERL 42.2113.000?

Upgrading a 4.0 gpm legacy fixture to NEOPERL 42.2113.000 saves ~26,280 gallons yearly for three occupants, about $289/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with NEOPERL 42.2113.000?

Pairing NEOPERL 42.2113.000 (1.0 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.0 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing NEOPERL 42.2113.000 require a municipal plumbing permit?

Like-for-like swaps using NEOPERL 42.2113.000 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How many gallons per person does NEOPERL 42.2113.000 save annually?

Each resident saves ~8,760 gallons yearly (75.0% drop) replacing a 4.0 gpm fixture with NEOPERL 42.2113.000 (1.0 gpm), or 3,504 gal/yr versus 2.2 gpm EPAct baselines.

Who should NOT install NEOPERL 42.2113.000 without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.0 gpm faucet.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories