Skip to main content
Grant Estimator

OmniPro OPH-500 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · OmniPro (1 SKU)
Verified Specification Summary

Homeowners upgrading older 2.75 gpm plumbing to OmniPro OPH-500 (1.0 gpm, #3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets) cut 63.6% off legacy draw, conserving ~7,665 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for OmniPro OPH-500 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.0 gpm
vs. EPAct 1992
-54.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,460 gal/yr
Annual Saved vs. Legacy
2,555 gal/person
Brand EPA Count
25 faucets
Series / Variants
OPH-500 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does OmniPro OPH-500 Benchmark & Water Budget show?

Laboratory testing places OmniPro OPH-500 at 1.0 gpm (aggressive sub-1.6 gpm conservation tier), saving 54.5% vs. EPAct 1992 (2.2 gpm) while ranking #3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets (0.20 gpm lower-flow than the 1.20 gpm median).

Pair this 1.0 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: OmniPro holds 25 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~7,665 gallons/yr—roughly $61/yr in low-tariff towns ($8/1k gal), $84/yr at national averages ($11/1k gal), or $138/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: allen + roth QFS6A0229 (1.0 gpm) and Belanger IND79C (1.0 gpm).

How do federal gpm limits contrast with OmniPro OPH-500 tested flow?

Each bar isolates OmniPro OPH-500 (1.00 gpm) relative to the EPA cap, federal EPAct 1992 standard (2.2 gpm), and pre-1994 draw.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): OPH-500: 1.00; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)OPH-500: 1.00OPH-5001.00EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.0 gpm: 1 gpm (8th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.0 gpm: 1 gpm (P8)

How does wet-zone tile prep interact with OmniPro OPH-500 rough-ins?

Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What plumbing standards accompany OmniPro OPH-500 installation?

Verify OmniPro OPH-500 EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share OmniPro (25 certified) EPA WaterSense Partner
Model Number / Series OPH-500 Certified Series (1 finish variants)
Rated Consumption 1.0 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

What household water budget fits OmniPro OPH-500?

Annual consumption rows below translate OmniPro OPH-500 certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.

Computed annual water savings for OmniPro OPH-500 (1.0 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,460 gal1,752 gal2,555 gal (~$28)
2 Occupants2,920 gal3,504 gal5,110 gal (~$56)
3 Occupants4,380 gal5,256 gal7,665 gal (~$61–$138)
4 Occupants5,840 gal7,008 gal10,220 gal (~$112)

Where can buyers find alternatives to OmniPro OPH-500?

Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen + roth QFS6A0229 1.0 gpm (Same flow) VEDA
Belanger IND79C 1.0 gpm (Same flow) WaterSense
Chicago Faucet E80-A11E-16ABCP 1.0 gpm (Same flow) WaterSense
Conservation Management Systems 50664xx 1.0 gpm (Same flow) WaterSense
Delta 24T2a7b 1.0 gpm (Same flow) WaterSense

What annual bill drop does OmniPro OPH-500 achieve for your family?

Calculate annual gallons conserved and dollar savings for OmniPro OPH-500 using your exact occupant count and utility tariff without submitting personal info.

Does OmniPro OPH-500 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying OmniPro OPH-500 for your remodel.

Limitations & Who Should Skip

  • Existing shower valve lacks ASSE 1016 pressure balancing

Best-Fit Homeowner Profiles

  • Strong scenario: Meeting 2.2 gpm federal & stricter WaterSense caps
  • Best application: Targeting ~$84/yr utility savings (3-person home)

Which code checks and cost facts matter for OmniPro OPH-500?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to OmniPro OPH-500.

Does OmniPro OPH-500 cut utility costs noticeably for a 3-person household?

Yes: cutting 26,280 gallons/yr relative to 4.0 gpm hardware translates to ~$289/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with OmniPro OPH-500?

Pairing OmniPro OPH-500 (1.0 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.0 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing OmniPro OPH-500 require a municipal plumbing permit?

Like-for-like swaps using OmniPro OPH-500 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What efficiency edge separates OmniPro OPH-500 from legacy and EPAct models?

Certified at 1.0 gpm, OmniPro OPH-500 achieves 54.5% savings against EPAct 1992 (2.2 gpm) and 75.0% savings against 4.0 gpm fixtures, 8,760 gallons per occupant yearly.

What supply pressure checks protect OmniPro OPH-500 spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.0 gpm trim.

Does OmniPro OPH-500 qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes OmniPro OPH-500 eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does OmniPro OPH-500 rank against other certified faucets?

Rated at 1.0 gpm, OmniPro OPH-500 measures below the 1.2 gpm WaterSense faucet median across thousands of EPA-listed residential fixtures.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories