Skip to main content
Grant Estimator

Vancomp 2004-L-XXXXXX-XX-1.0 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · Vancomp (1 SKU)
Verified Specification Summary

Certified under EPA WaterSense, Vancomp 2004-L-XXXXXX-XX-1.0 tests at 1.0 gpm (#3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets), trimming 54.5% off the 2.2 gpm federal cap while cutting 3-person household draw by ~7,665 gal/yr versus 2.75 gpm fixtures. Compare EPA WaterSense certified flow metrics for Vancomp 2004-L-XXXXXX-XX-1.0 WaterSense Faucet, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.0 gpm
vs. EPAct 1992
-54.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,460 gal/yr
Annual Saved vs. Legacy
2,555 gal/person
Brand EPA Count
66 faucets
Series / Variants
2004-L-XXXXXX-XX-1.0 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Vancomp 2004-L-XXXXXX-XX-1.0 Benchmark & Water Budget show?

Efficiency check: certified at 1.0 gpm, Vancomp 2004-L-XXXXXX-XX-1.0 trims 54.5% under federal 2.2 gpm caps; #3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets (0.20 gpm lower-flow than the 1.20 gpm median).

Pair this 1.0 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Vancomp holds 66 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~7,665 gallons/yr—roughly $61/yr in low-tariff towns ($8/1k gal), $84/yr at national averages ($11/1k gal), or $138/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: allen + roth QFS6A0229 (1.0 gpm) and Belanger IND79C (1.0 gpm).

Where does Vancomp 2004-L-XXXXXX-XX-1.0 sit on the EPA WaterSense faucet flow curve?

Comparing Vancomp 2004-L-XXXXXX-XX-1.0 (1.00 gpm) against federal EPAct (2.2 gpm) and legacy (2.75 gpm) baselines shows immediate per-use conservation.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 2004-L-XXXXXX-XX-1.0: 1.00; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)2004-L-XXXXXX-XX-1.0: 1.002004-L-XXXXXX-XX-1.01.00EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.0 gpm: 1 gpm (8th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.0 gpm: 1 gpm (P8)

How do subfloor levelness and rough-in height protect Vancomp 2004-L-XXXXXX-XX-1.0?

Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What official WaterSense figures verify Vancomp 2004-L-XXXXXX-XX-1.0?

Examine Vancomp 2004-L-XXXXXX-XX-1.0 certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Vancomp (66 certified) EPA WaterSense Partner
Model Number / Series 2004-L-XXXXXX-XX-1.0 Certified Series (1 finish variants)
Rated Consumption 1.0 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

What annual utility savings does Vancomp 2004-L-XXXXXX-XX-1.0 deliver?

Compare 1-to-4-person household water use with Vancomp 2004-L-XXXXXX-XX-1.0 against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.

Computed annual water savings for Vancomp 2004-L-XXXXXX-XX-1.0 (1.0 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,460 gal1,752 gal2,555 gal (~$28)
2 Occupants2,920 gal3,504 gal5,110 gal (~$56)
3 Occupants4,380 gal5,256 gal7,665 gal (~$61–$138)
4 Occupants5,840 gal7,008 gal10,220 gal (~$112)

What alternative WaterSense models compare to Vancomp 2004-L-XXXXXX-XX-1.0?

Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen + roth QFS6A0229 1.0 gpm (Same flow) VEDA
Belanger IND79C 1.0 gpm (Same flow) WaterSense
Chicago Faucet E80-A11E-16ABCP 1.0 gpm (Same flow) WaterSense
Conservation Management Systems 50664xx 1.0 gpm (Same flow) WaterSense
Delta 24T2a7b 1.0 gpm (Same flow) WaterSense

What will Vancomp 2004-L-XXXXXX-XX-1.0 save on your annual water bill?

Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.

Where should contractors skip Vancomp 2004-L-XXXXXX-XX-1.0 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Vancomp 2004-L-XXXXXX-XX-1.0 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Existing shower valve lacks ASSE 1016 pressure balancing

Best-Fit Homeowner Profiles

  • Choose this if: Meeting 2.2 gpm federal & stricter WaterSense caps
  • Works well for: Targeting ~$84/yr utility savings (3-person home)

Which homeowner questions come up most for Vancomp 2004-L-XXXXXX-XX-1.0?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Vancomp 2004-L-XXXXXX-XX-1.0.

Is Vancomp 2004-L-XXXXXX-XX-1.0 leaner than typical WaterSense faucet models?

Compared with the 1.2 gpm WaterSense faucet median, Vancomp 2004-L-XXXXXX-XX-1.0's 1.0 gpm rating places it below category norms inside EPA conservation limits.

What annual dollar savings can a 3-person home expect with Vancomp 2004-L-XXXXXX-XX-1.0?

Upgrading a 4.0 gpm legacy fixture to Vancomp 2004-L-XXXXXX-XX-1.0 saves ~26,280 gallons yearly for three occupants, about $289/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with Vancomp 2004-L-XXXXXX-XX-1.0?

Pairing Vancomp 2004-L-XXXXXX-XX-1.0 (1.0 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.0 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Vancomp 2004-L-XXXXXX-XX-1.0 require a municipal plumbing permit?

Like-for-like swaps using Vancomp 2004-L-XXXXXX-XX-1.0 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How many gallons per person does Vancomp 2004-L-XXXXXX-XX-1.0 save annually?

Each resident saves ~8,760 gallons yearly (75.0% drop) replacing a 4.0 gpm fixture with Vancomp 2004-L-XXXXXX-XX-1.0 (1.0 gpm), or 3,504 gal/yr versus 2.2 gpm EPAct baselines.

Who should NOT install Vancomp 2004-L-XXXXXX-XX-1.0 without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.0 gpm faucet.

Can homeowners claim utility rebates when installing Vancomp 2004-L-XXXXXX-XX-1.0?

Because Vancomp 2004-L-XXXXXX-XX-1.0 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories