CATO J2004XXXXXX WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · Terra Handicap (1 SKU)
Verified Specification Summary

Certified under EPA WaterSense, CATO J2004XXXXXX tests at 1.12 gpf (#580 of 3,875 rated single-flush models (out of 6,793 certified toilets); most water-efficient 15.0% of 3,875 rated single-flush models, lower-flow than 85.0% of rated single-flush models), trimming 30.0% off the 1.6 gpf federal cap while cutting 3-person household draw by ~13,032 gal/yr versus 3.5 gpf fixtures.

Certified Flow
1.12 gpf
vs. EPAct 1992
-30.0% (1.6 gpf)
Annual Draw (1 Pers.)
2,044 gal/yr
Annual Saved vs. Legacy
4,344 gal/person
Brand EPA Count
14 toilets
Series / Variants
J2004XXXXXX (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does CATO J2004XXXXXX Benchmark & Water Budget show?

Efficiency check: certified at 1.12 gpf, CATO J2004XXXXXX (Terra Handicap) trims 30.0% under federal 1.6 gpf caps; #580 of 3,875 rated single-flush models; most water-efficient 15.0% of 3,875 rated single-flush models, lower-flow than 85.0% of rated single-flush models (0.16 gpf lower-flow than the 1.28 gpf median). Bowl 1E06 / Tank 2A04.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.12 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: CATO holds 14 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~13,032 gallons/yr—roughly $104/yr in low-tariff towns ($8/1k gal), $143/yr at national averages ($11/1k gal), or $235/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: American Standard 2467100 (1.1 gpf) and American Standard 288AA114 (1.1 gpf).

Where does CATO J2004XXXXXX sit on the EPA WaterSense toilet flow curve?

Comparing CATO J2004XXXXXX (1.12 gpf) against federal EPAct (1.6 gpf) and legacy (3.5 gpf) baselines shows immediate per-use conservation.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): J2004XXXXXX: 1.12; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)J2004XXXXXX: 1.12J2004XXXXXX1.12EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 1.12 gpf: 1.12 gpf (15th percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf1.12 gpf: 1.12 gpf (P15)

How do subfloor levelness and rough-in height protect CATO J2004XXXXXX?

Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What official WaterSense figures verify CATO J2004XXXXXX?

Examine CATO J2004XXXXXX certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share CATO (14 certified) EPA WaterSense Partner
Model Number / Series J2004XXXXXX Terra Handicap (1 finish variants)
Rated Consumption 1.12 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Gravity Verify rough-in & supply pressure

What annual utility savings does CATO J2004XXXXXX deliver?

Compare 1-to-4-person household water use with CATO J2004XXXXXX against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.

Computed annual water savings for CATO J2004XXXXXX (1.12 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant2,044 gal876 gal4,344 gal (~$48)
2 Occupants4,088 gal1,752 gal8,688 gal (~$96)
3 Occupants6,132 gal2,628 gal13,032 gal (~$104–$235)
4 Occupants8,176 gal3,504 gal17,376 gal (~$191)

What alternative WaterSense models compare to CATO J2004XXXXXX?

Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
American Standard 2467100 1.1 gpf (-0.02) Single / Pressure Assist
American Standard 288AA114 1.1 gpf (-0.02) Single / Gravity
American Standard 288CA114 1.1 gpf (-0.02) Single / Gravity
American Standard 288DA114 1.1 gpf (-0.02) Single / Gravity
Axent AT5560-XX/AT5561 1.1 gpf (-0.02) Single / Pressure Assist

What will CATO J2004XXXXXX save on your annual water bill?

Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.

What plumbing or duct constraints rule out CATO J2004XXXXXX?

Compare where CATO J2004XXXXXX excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Building drain lacks 1/4 in/ft slope for reduced flush carry

Best-Fit Homeowner Profiles

  • Homeowner profile: Meeting 1.6 gpf federal & stricter WaterSense caps
  • Suited to: Targeting ~$143/yr utility savings (3-person home)

Which homeowner questions come up most for CATO J2004XXXXXX?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around CATO J2004XXXXXX.

Why upgrade a 3.5 gpf fixture to CATO J2004XXXXXX at 1.12 gpf?

Swapping a 3.5 gpf unit for CATO J2004XXXXXX slashes water draw 68.0% (4,344 gal/person/yr), beating 1.6 gpf federal EPAct standards by 30.0%.

When does switching to CATO J2004XXXXXX (1.12 gpf) require a drain inspection?

Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 1.12 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.

How do 133 WaterSense rebate programs treat CATO J2004XXXXXX?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like CATO J2004XXXXXX, itemized purchase invoices, and residential installation addresses.

How does CATO J2004XXXXXX perform relative to the EPA WaterSense category median?

Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 1.12 gpf, CATO J2004XXXXXX sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to CATO J2004XXXXXX?

At $11 per 1,000 gallons, a 3-person household conserving 13,032 gallons/yr with CATO J2004XXXXXX trims roughly $143 annually off water and sewer utility bills.

What closet flange and side-wall clearances apply to CATO J2004XXXXXX?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 1.12 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing CATO J2004XXXXXX require a municipal plumbing permit?