Skip to main content
Grant Estimator

Contrac 5730BEVU WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · Cato (2 SKUs)
Verified Specification Summary

The Contrac 5730BEVU is an EPA WaterSense toilet certified at 1.0 gpf, 37.5% below EPAct 1992 (1.6 gpf) and #165 of 3,875 rated single-flush models (out of 6,793 certified toilets); most water-efficient 12.8% of 3,875 rated single-flush models, lower-flow than 87.2% of rated single-flush models. A 3-person household saves ~13,689 gallons/yr replacing a 3.5 gpf legacy fixture.

Certified Flow
1.0 gpf
vs. EPAct 1992
-37.5% (1.6 gpf)
Annual Draw (1 Pers.)
1,825 gal/yr
Annual Saved vs. Legacy
4,563 gal/person
Brand EPA Count
116 toilets
Series / Variants
5730BEVU (2)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Contrac 5730BEVU Benchmark & Water Budget show?

Flow standing: Contrac 5730BEVU (Cato) operates at 1.0 gpf (ultra-low sub-1.1 gpf tier), #165 of 3,875 rated single-flush models; most water-efficient 12.8% of 3,875 rated single-flush models, lower-flow than 87.2% of rated single-flush models (0.28 gpf lower-flow than the 1.28 gpf median), cutting 37.5% off EPAct 1992 (1.6 gpf). Bowl B5730BEVU / Tank T5730BEVU.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.0 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: Contrac holds 116 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~13,689 gallons/yr—roughly $110/yr in low-tariff towns ($8/1k gal), $151/yr at national averages ($11/1k gal), or $246/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: Abath KBF-TPT001 (1.0 gpf) and American Standard 238AA115 (1.0 gpf).

How does Contrac 5730BEVU compare to EPAct 1992 and legacy gpf rates?

Tested at 1.00 gpf, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (1.6 gpf) and pre-1994 legacy units (3.5 gpf).

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): 5730BEVU: 1.00; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)5730BEVU: 1.005730BEVU1.00EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 1.0 gpf: 1 gpf (13th percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf1.0 gpf: 1 gpf (P13)

What floor flatness and flange clearances pair with Contrac 5730BEVU?

Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which EPA WaterSense test specs apply to Contrac 5730BEVU?

Certified EPA WaterSense records for Contrac 5730BEVU verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Contrac (116 certified) EPA WaterSense Partner
Model Number / Series 5730BEVU Cato (2 finish variants)
Rated Consumption 1.0 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Gravity Verify rough-in & supply pressure

Which 2 finish and trim SKUs share the Contrac 5730BEVU WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 2 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into Contrac 5730BEVU (2 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
5730BEVU*1.0 gpfCato
5730BEV*1.0 gpfCato

How much water and money can Contrac 5730BEVU save each year?

Household projections below calculate Contrac 5730BEVU annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.

Computed annual water savings for Contrac 5730BEVU (1.0 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,825 gal1,095 gal4,563 gal (~$50)
2 Occupants3,650 gal2,190 gal9,126 gal (~$100)
3 Occupants5,475 gal3,285 gal13,689 gal (~$110–$246)
4 Occupants7,300 gal4,380 gal18,252 gal (~$201)

Which EPA WaterSense fixtures match Contrac 5730BEVU?

Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
Abath KBF-TPT001 1.0 gpf (Same flow) Single / Gravity
American Standard 238AA115 1.0 gpf (Same flow) Single / Gravity
American Standard 2548A100 1.0 gpf (Same flow) Single / Pressure Assist
American Standard 740AA101 1.0 gpf (Same flow) Single / Gravity
AXENT R60-E 1.0 gpf (Same flow) Single / Pressure Assist

How much does Contrac 5730BEVU save at your local water rate?

Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.

What plumbing or duct constraints rule out Contrac 5730BEVU?

Compare where Contrac 5730BEVU excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Legacy cast-iron drain has reverse slope (camera scope before <1.28 gpf drop)

Best-Fit Homeowner Profiles

  • Homeowner profile: Claiming utility rebates across 200 U.S. WaterSense programs
  • Suited to: Lowering household draw to 1,825 gal/person/yr

What key rules and numbers govern Contrac 5730BEVU?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Contrac 5730BEVU.

How do 133 WaterSense rebate programs treat Contrac 5730BEVU?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Contrac 5730BEVU, itemized purchase invoices, and residential installation addresses.

How does Contrac 5730BEVU perform relative to the EPA WaterSense category median?

Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 1.0 gpf, Contrac 5730BEVU sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Contrac 5730BEVU?

At $11 per 1,000 gallons, a 3-person household conserving 13,686 gallons/yr with Contrac 5730BEVU trims roughly $151 annually off water and sewer utility bills.

What closet flange and side-wall clearances apply to Contrac 5730BEVU?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 1.0 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing Contrac 5730BEVU require a municipal plumbing permit?

Like-for-like swaps using Contrac 5730BEVU on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 3.5 gpf fixture to Contrac 5730BEVU at 1.0 gpf?

Swapping a 3.5 gpf unit for Contrac 5730BEVU slashes water draw 71.4% (4,562 gal/person/yr), beating 1.6 gpf federal EPAct standards by 37.5%.

When does switching to Contrac 5730BEVU (1.0 gpf) require a drain inspection?

Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 1.0 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories