Skip to main content
Grant Estimator

Mansfield 1013-1012 WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · Maverick (1 SKU)
Verified Specification Summary

Operating at 1.1 gpf, the Mansfield 1013-1012 toilet beats 1992 EPAct rules (1.6 gpf) by 31.2% (#530 of 3,875 rated single-flush models (out of 6,793 certified toilets); most water-efficient 14.9% of 3,875 rated single-flush models, lower-flow than 85.1% of rated single-flush models), saving a 3-resident home ~13,140 gallons annually compared to 3.5 gpf legacy hardware. Compare EPA WaterSense certified flow metrics for Mansfield 1013-1012 WaterSense Toilet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.1 gpf
vs. EPAct 1992
-31.2% (1.6 gpf)
Annual Draw (1 Pers.)
2,008 gal/yr
Annual Saved vs. Legacy
4,380 gal/person
Brand EPA Count
74 toilets
Series / Variants
1013-1012 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Mansfield 1013-1012 Benchmark & Water Budget show?

WaterSense benchmark: Mansfield series 1013-1012 (Maverick) verifies 1.1 gpf delivery, scoring 31.2% leaner than EPAct 1992 (1.6 gpf) at #530 of 3,875 rated single-flush models; most water-efficient 14.9% of 3,875 rated single-flush models, lower-flow than 85.1% of rated single-flush models (0.18 gpf lower-flow than the 1.28 gpf median). Bowl 1013 / Tank 1012.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.1 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: Mansfield holds 74 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~13,140 gallons/yr—roughly $105/yr in low-tariff towns ($8/1k gal), $145/yr at national averages ($11/1k gal), or $237/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Glendale Environmental Resources Department (AZ) list active rebates among 200 U.S. programs. Closest alternatives: American Standard 2467100 (1.1 gpf) and American Standard 288AA114 (1.1 gpf).

How much leaner is Mansfield 1013-1012 than pre-1994 3.5 gpf plumbing?

Flow distribution bars contrast Mansfield 1013-1012 (1.10 gpf) directly with the 1.28 gpf WaterSense median and 3.5 gpf older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): 1013-1012: 1.10; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)1013-1012: 1.101013-10121.10EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 1.1 gpf: 1.1 gpf (15th percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf1.1 gpf: 1.1 gpf (P15)

Which framing and flange tolerances matter before installing Mansfield 1013-1012?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does Mansfield 1013-1012 compare to WaterSense category caps?

Each specification row below documents Mansfield 1013-1012 tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Mansfield (74 certified) EPA WaterSense Partner
Model Number / Series 1013-1012 Maverick (1 finish variants)
Rated Consumption 1.1 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Gravity Verify rough-in & supply pressure

How many gallons per year does Mansfield 1013-1012 cut?

Calculated annual water budgets below quantify Mansfield 1013-1012 savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for Mansfield 1013-1012 (1.1 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant2,008 gal912 gal4,380 gal (~$48)
2 Occupants4,016 gal1,824 gal8,760 gal (~$96)
3 Occupants6,024 gal2,736 gal13,140 gal (~$105–$237)
4 Occupants8,032 gal3,648 gal17,520 gal (~$193)

Which competing models share Mansfield 1013-1012 flow tier?

Review five peer WaterSense units matching Mansfield 1013-1012 conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
American Standard 2467100 1.1 gpf (Same flow) Single / Pressure Assist
American Standard 288AA114 1.1 gpf (Same flow) Single / Gravity
American Standard 288CA114 1.1 gpf (Same flow) Single / Gravity
American Standard 288DA114 1.1 gpf (Same flow) Single / Gravity
Axent AT5560-XX/AT5561 1.1 gpf (Same flow) Single / Pressure Assist

Can you estimate Mansfield 1013-1012 payback in your home?

Test how many gallons and dollars Mansfield 1013-1012 saves each year by entering your household residents and local water-sewer rate below.

Does Mansfield 1013-1012 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Mansfield 1013-1012 for your remodel.

Limitations & Who Should Skip

  • Unvented branch drain causing slow bowl clear

Best-Fit Homeowner Profiles

  • Strong scenario: Upgrading 3.5 gpf fixtures for 68.6% water reduction
  • Best application: Matching Mansfield SKU 1013-1012 certification on rebate forms

How do federal and code standards apply to Mansfield 1013-1012?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Mansfield 1013-1012.

What efficiency edge separates Mansfield 1013-1012 from legacy and EPAct models?

Certified at 1.1 gpf, Mansfield 1013-1012 achieves 31.2% savings against EPAct 1992 (1.6 gpf) and 68.6% savings against 3.5 gpf fixtures, 4,380 gallons per occupant yearly.

Are older sewer lines safe for Mansfield 1013-1012's 1.1 gpf flush volume?

Most copper/PVC lines handle 1.1 gpf cleanly, whereas sagging or scaled cast-iron laterals lacking 1/4 in/ft slope should be scoped prior to replacing 3.5 gpf bowls.

Does Mansfield 1013-1012 qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes Mansfield 1013-1012 eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does Mansfield 1013-1012 rank against other certified toilets?

Rated at 1.1 gpf, Mansfield 1013-1012 measures below the 1.28 gpf WaterSense toilet median across thousands of EPA-listed residential fixtures.

Does Mansfield 1013-1012 cut utility costs noticeably for a 3-person household?

Yes: cutting 13,140 gallons/yr relative to 3.5 gpf hardware translates to ~$145/yr in combined water/sewer savings at $11/1k gal.

What closet flange and side-wall clearances apply to Mansfield 1013-1012?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 1.1 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing Mansfield 1013-1012 require a municipal plumbing permit?

Like-for-like swaps using Mansfield 1013-1012 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories