SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · Integrated Intelligent Toilet (4 SKUs)
Verified Specification Summary

Listed in EPA WaterSense files at 1.06 gpf, SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... achieves #501 of 3,875 rated single-flush models (out of 6,793 certified toilets); most water-efficient 13.7% of 3,875 rated single-flush models, lower-flow than 86.3% of rated single-flush models and lowers household water use ~13,359 gal/yr (3 residents) against pre-1994 3.5 gpf fixtures. Compare EPA WaterSense certified flow metrics for SANIWISE Model, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.06 gpf
vs. EPAct 1992
-33.8% (1.6 gpf)
Annual Draw (1 Pers.)
1,935 gal/yr
Annual Saved vs. Legacy
4,453 gal/person
Brand EPA Count
12 toilets
Series / Variants
Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... (4)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... Benchmark & Water Budget show?

Certified discharge for SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... (Integrated Intelligent Toilet) measures 1.06 gpf (ultra-low sub-1.1 gpf tier), standing #501 of 3,875 rated single-flush models; most water-efficient 13.7% of 3,875 rated single-flush models, lower-flow than 86.3% of rated single-flush models (0.22 gpf lower-flow than the 1.28 gpf median) against the 1.6 gpf standard.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.06 gpf bowl (Pressure Assist flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: SANIWISE holds 12 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~13,359 gallons/yr—roughly $107/yr in low-tariff towns ($8/1k gal), $147/yr at national averages ($11/1k gal), or $240/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: HOROW T03-PR (1.06 gpf) and Kohler K-77780 (1.06 gpf).

Does SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... beat the 1.28 gpf WaterSense toilet median?

Certified at 1.06 gpf, SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... sits well under EPAct 1992 limits (1.6 gpf) across 6,793 EPA-registered toilets.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): Model:D17-(1)(2)(3)(: 1.06; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Model:D17-(1)(2)(3)(: 1.06Model:D17-(1)(2)(3)(1.06EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 1.06 gpf: 1.06 gpf (14th percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf1.06 gpf: 1.06 gpf (P14)

Why check closet flange height and L/360 stiffness around SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1...?

Checking framing deflection (L/360) and finished tile-to-flange elevation before fixture mounting eliminates wobble and concealed floor leaks.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Where does SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... fit in EPA WaterSense files?

Review certified water flow, brand lineup breadth, and ASSE 1016 valve or IPC closet flange pairing guidelines for SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1....

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share SANIWISE (12 certified) EPA WaterSense Partner
Model Number / Series Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... Integrated Intelligent Toilet (4 finish variants)
Rated Consumption 1.06 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Pressure Assist Verify rough-in & supply pressure

Which 4 finish and trim SKUs share the SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 4 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... (4 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1...1.06 gpfIntegrated Intelligent Toilet
Model:D07-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1...1.06 gpfIntegrated Intelligent Toilet
Model:D16-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1...1.06 gpfIntegrated Intelligent Toilet
Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1...1.06 gpfIntegrated Intelligent Toilet

Does SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... lower water bills for larger households?

Review computed annual water totals for 1 to 4 residents comparing SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... certified consumption with older pre-1994 residential plumbing hardware.

Computed annual water savings for SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... (1.06 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,935 gal985 gal4,453 gal (~$49)
2 Occupants3,870 gal1,970 gal8,906 gal (~$98)
3 Occupants5,805 gal2,955 gal13,359 gal (~$107–$240)
4 Occupants7,740 gal3,940 gal17,812 gal (~$196)

How do similar WaterSense brands compare with SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1...?

Comparable certified models listed below share SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... category standards while offering alternative brand warranties and rough-in configurations.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
HOROW T03-PR 1.06 gpf (Same flow) Single / Pressure Assist
Kohler K-77780 1.06 gpf (Same flow) Single / Other
American Standard 2467100 1.1 gpf (+0.04) Single / Pressure Assist
American Standard 288AA114 1.1 gpf (+0.04) Single / Gravity
American Standard 288CA114 1.1 gpf (+0.04) Single / Gravity

How do local water rates change SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... savings?

Use the local browser estimator below with your city water-sewer rate and household size to quantify SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... yearly utility impact.

What plumbing or duct constraints rule out SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8?

Compare where SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Legacy cast-iron drain has reverse slope (camera scope before <1.28 gpf drop)

Best-Fit Homeowner Profiles

  • Homeowner profile: Claiming utility rebates across 200 U.S. WaterSense programs
  • Suited to: Lowering household draw to 1,935 gal/person/yr

What should homeowners verify first about SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1...?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1....

When does switching to SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... , 1.06 gpf require a drain inspection?

Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 1.06 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.

How do 133 WaterSense rebate programs treat SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1...?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1..., itemized purchase invoices, and residential installation addresses.

How does SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... perform relative to the EPA WaterSense category median?

Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 1.06 gpf, SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1...?

At $11 per 1,000 gallons, a 3-person household conserving 13,359 gallons/yr with SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... trims roughly $147 annually off water and sewer utility bills.

What closet flange and side-wall clearances apply to SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1...?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 1.06 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... require a municipal plumbing permit?

Like-for-like swaps using SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 3.5 gpf fixture to SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... at 1.06 gpf?

Swapping a 3.5 gpf unit for SANIWISE Model:D17-(1)(2)(3)(4)(5)(6)(7)(8)(9)(1... slashes water draw 69.7% , 4,453 gal/person/yr, beating 1.6 gpf federal EPAct standards by 33.8%.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories