Listed in EPA WaterSense files at 1.0 gpf, Tynan 4512.XX achieves #165 of 3,875 rated single-flush models (out of 6,793 certified toilets); most water-efficient 12.8% of 3,875 rated single-flush models, lower-flow than 87.2% of rated single-flush models and lowers household water use ~13,689 gal/yr (3 residents) against pre-1994 3.5 gpf fixtures. Compare EPA WaterSense certified flow metrics for Tynan 4512.XX WaterSense Toilet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 1.0 gpf
- vs. EPAct 1992
- -37.5% (1.6 gpf)
- Annual Draw (1 Pers.)
- 1,825 gal/yr
- Annual Saved vs. Legacy
- 4,563 gal/person
- Brand EPA Count
- 242 toilets
- Series / Variants
- 4512.XX (1)

What does Tynan 4512.XX Benchmark & Water Budget show?
Certified discharge for Tynan 4512.XX measures 1.0 gpf (ultra-low sub-1.1 gpf tier), standing #165 of 3,875 rated single-flush models; most water-efficient 12.8% of 3,875 rated single-flush models, lower-flow than 87.2% of rated single-flush models (0.28 gpf lower-flow than the 1.28 gpf median) against the 1.6 gpf standard. Bowl 7512 / Tank 1712.
For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.0 gpf bowl (Pressure Assist flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.
Brand breadth: Tynan holds 242 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~13,689 gallons/yr—roughly $110/yr in low-tariff towns ($8/1k gal), $151/yr at national averages ($11/1k gal), or $246/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: Abath KBF-TPT001 (1.0 gpf) and American Standard 238AA115 (1.0 gpf).
Does Tynan 4512.XX beat the 1.28 gpf WaterSense toilet median?
Certified at 1.00 gpf, Tynan 4512.XX sits well under EPAct 1992 limits (1.6 gpf) across 6,793 EPA-registered toilets.
Why check closet flange height and L/360 stiffness around Tynan 4512.XX?
Checking framing deflection (L/360) and finished tile-to-flange elevation before fixture mounting eliminates wobble and concealed floor leaks.
Where does Tynan 4512.XX fit in EPA WaterSense files?
Review certified water flow, brand lineup breadth, and ASSE 1016 valve or IPC closet flange pairing guidelines for Tynan 4512.XX.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | Tynan (242 certified) | EPA WaterSense Partner |
| Model Number / Series | 4512.XX | Certified Series (1 finish variants) |
| Rated Consumption | 1.0 gpf | Category median 1.28 gpf (n=3,875 rated) |
| Flush / Valve Architecture | Single / Pressure Assist | Verify rough-in & supply pressure |
Does Tynan 4512.XX lower water bills for larger households?
Review computed annual water totals for 1 to 4 residents comparing Tynan 4512.XX certified consumption with older pre-1994 residential plumbing hardware.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 1,825 gal | 1,095 gal | 4,563 gal (~$50) |
| 2 Occupants | 3,650 gal | 2,190 gal | 9,126 gal (~$100) |
| 3 Occupants | 5,475 gal | 3,285 gal | 13,689 gal (~$110–$246) |
| 4 Occupants | 7,300 gal | 4,380 gal | 18,252 gal (~$201) |
How do similar WaterSense brands compare with Tynan 4512.XX?
Comparable certified models listed below share Tynan 4512.XX category standards while offering alternative brand warranties and rough-in configurations.
| Peer Brand & Model | Rated GPF (Delta) | Flush / Model Detail |
|---|---|---|
| Abath KBF-TPT001 | 1.0 gpf (Same flow) | Single / Gravity |
| American Standard 238AA115 | 1.0 gpf (Same flow) | Single / Gravity |
| American Standard 2548A100 | 1.0 gpf (Same flow) | Single / Pressure Assist |
| American Standard 740AA101 | 1.0 gpf (Same flow) | Single / Gravity |
| AXENT R60-E | 1.0 gpf (Same flow) | Single / Pressure Assist |
How do local water rates change Tynan 4512.XX savings?
Use the local browser estimator below with your city water-sewer rate and household size to quantify Tynan 4512.XX yearly utility impact.
What plumbing or duct constraints rule out Tynan 4512.XX?
Compare where Tynan 4512.XX excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Legacy cast-iron drain has reverse slope (camera scope before <1.28 gpf drop)
Best-Fit Homeowner Profiles
- Homeowner profile: Claiming utility rebates across 200 U.S. WaterSense programs
- Suited to: Lowering household draw to 1,825 gal/person/yr
What should homeowners verify first about Tynan 4512.XX?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Tynan 4512.XX.
When does switching to Tynan 4512.XX (1.0 gpf) require a drain inspection?
Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 1.0 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.
How do 133 WaterSense rebate programs treat Tynan 4512.XX?
Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Tynan 4512.XX, itemized purchase invoices, and residential installation addresses.
How does Tynan 4512.XX perform relative to the EPA WaterSense category median?
Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 1.0 gpf, Tynan 4512.XX sits below the category median while clearing federal WaterSense caps.
How much does a 3-resident family save yearly switching to Tynan 4512.XX?
At $11 per 1,000 gallons, a 3-person household conserving 13,686 gallons/yr with Tynan 4512.XX trims roughly $151 annually off water and sewer utility bills.
What closet flange and side-wall clearances apply to Tynan 4512.XX?
IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).
How is EPA WaterSense performance tested beyond raw gpf flow caps?
EPA WaterSense certification pairs the 1.0 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.
Does installing Tynan 4512.XX require a municipal plumbing permit?
Like-for-like swaps using Tynan 4512.XX on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
Why upgrade a 3.5 gpf fixture to Tynan 4512.XX at 1.0 gpf?
Swapping a 3.5 gpf unit for Tynan 4512.XX slashes water draw 71.4% (4,562 gal/person/yr), beating 1.6 gpf federal EPAct standards by 37.5%.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)