Skip to main content
Grant Estimator

Vortens™ 3138/3468 WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · Tornado EL (1 SKU)
Verified Specification Summary

The Vortens™ 3138/3468 is an EPA WaterSense toilet certified at 1.0 gpf, 37.5% below EPAct 1992 (1.6 gpf) and #165 of 3,875 rated single-flush models (out of 6,793 certified toilets); most water-efficient 12.8% of 3,875 rated single-flush models, lower-flow than 87.2% of rated single-flush models. A 3-person household saves ~13,689 gallons/yr replacing a 3.5 gpf legacy fixture.

Certified Flow
1.0 gpf
vs. EPAct 1992
-37.5% (1.6 gpf)
Annual Draw (1 Pers.)
1,825 gal/yr
Annual Saved vs. Legacy
4,563 gal/person
Brand EPA Count
47 toilets
Series / Variants
3138/3468 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Vortens™ 3138/3468 Benchmark & Water Budget show?

Flow standing: Vortens™ 3138/3468 (Tornado EL) operates at 1.0 gpf (ultra-low sub-1.1 gpf tier), #165 of 3,875 rated single-flush models; most water-efficient 12.8% of 3,875 rated single-flush models, lower-flow than 87.2% of rated single-flush models (0.28 gpf lower-flow than the 1.28 gpf median), cutting 37.5% off EPAct 1992 (1.6 gpf). Bowl 3138-V / Tank 3468-V.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.0 gpf bowl (Pressure Assist flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: Vortens™ holds 47 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~13,689 gallons/yr—roughly $110/yr in low-tariff towns ($8/1k gal), $151/yr at national averages ($11/1k gal), or $246/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Phoenix (AZ) list active rebates among 200 U.S. programs. Closest alternatives: Abath KBF-TPT001 (1.0 gpf) and American Standard 238AA115 (1.0 gpf).

How does Vortens™ 3138/3468 compare to EPAct 1992 and legacy gpf rates?

Tested at 1.00 gpf, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (1.6 gpf) and pre-1994 legacy units (3.5 gpf).

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): 3138/3468: 1.00; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)3138/3468: 1.003138/34681.00EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 1.0 gpf: 1 gpf (13th percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf1.0 gpf: 1 gpf (P13)

What floor flatness and flange clearances pair with Vortens™ 3138/3468?

Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which EPA WaterSense test specs apply to Vortens™ 3138/3468?

Certified EPA WaterSense records for Vortens™ 3138/3468 verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Vortens™ (47 certified) EPA WaterSense Partner
Model Number / Series 3138/3468 Tornado EL (1 finish variants)
Rated Consumption 1.0 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Pressure Assist Verify rough-in & supply pressure

How much water and money can Vortens™ 3138/3468 save each year?

Household projections below calculate Vortens™ 3138/3468 annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.

Computed annual water savings for Vortens™ 3138/3468 (1.0 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,825 gal1,095 gal4,563 gal (~$50)
2 Occupants3,650 gal2,190 gal9,126 gal (~$100)
3 Occupants5,475 gal3,285 gal13,689 gal (~$110–$246)
4 Occupants7,300 gal4,380 gal18,252 gal (~$201)

Which EPA WaterSense fixtures match Vortens™ 3138/3468?

Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
Abath KBF-TPT001 1.0 gpf (Same flow) Single / Gravity
American Standard 238AA115 1.0 gpf (Same flow) Single / Gravity
American Standard 2548A100 1.0 gpf (Same flow) Single / Pressure Assist
American Standard 740AA101 1.0 gpf (Same flow) Single / Gravity
AXENT R60-E 1.0 gpf (Same flow) Single / Pressure Assist

How much does Vortens™ 3138/3468 save at your local water rate?

Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.

What plumbing or duct constraints rule out Vortens™ 3138/3468?

Compare where Vortens™ 3138/3468 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Legacy cast-iron drain has reverse slope (camera scope before <1.28 gpf drop)

Best-Fit Homeowner Profiles

  • Homeowner profile: Claiming utility rebates across 200 U.S. WaterSense programs
  • Suited to: Lowering household draw to 1,825 gal/person/yr

What key rules and numbers govern Vortens™ 3138/3468?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Vortens™ 3138/3468.

How do 133 WaterSense rebate programs treat Vortens™ 3138/3468?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Vortens™ 3138/3468, itemized purchase invoices, and residential installation addresses.

How does Vortens™ 3138/3468 perform relative to the EPA WaterSense category median?

Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 1.0 gpf, Vortens™ 3138/3468 sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Vortens™ 3138/3468?

At $11 per 1,000 gallons, a 3-person household conserving 13,686 gallons/yr with Vortens™ 3138/3468 trims roughly $151 annually off water and sewer utility bills.

What closet flange and side-wall clearances apply to Vortens™ 3138/3468?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 1.0 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing Vortens™ 3138/3468 require a municipal plumbing permit?

Like-for-like swaps using Vortens™ 3138/3468 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 3.5 gpf fixture to Vortens™ 3138/3468 at 1.0 gpf?

Swapping a 3.5 gpf unit for Vortens™ 3138/3468 slashes water draw 71.4% (4,562 gal/person/yr), beating 1.6 gpf federal EPAct standards by 37.5%.

When does switching to Vortens™ 3138/3468 (1.0 gpf) require a drain inspection?

Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 1.0 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories