Skip to main content
Grant Estimator

Western B722+T7ULF WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · Western (1 SKU)
Verified Specification Summary

Certified under EPA WaterSense, Western B722+T7ULF tests at 1.0 gpf (#165 of 3,875 rated single-flush models (out of 6,793 certified toilets); most water-efficient 12.8% of 3,875 rated single-flush models, lower-flow than 87.2% of rated single-flush models), trimming 37.5% off the 1.6 gpf federal cap while cutting 3-person household draw by ~13,689 gal/yr versus 3.5 gpf fixtures.

Certified Flow
1.0 gpf
vs. EPAct 1992
-37.5% (1.6 gpf)
Annual Draw (1 Pers.)
1,825 gal/yr
Annual Saved vs. Legacy
4,563 gal/person
Brand EPA Count
7 toilets
Series / Variants
B722+T7ULF (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Western B722+T7ULF Benchmark & Water Budget show?

Efficiency check: certified at 1.0 gpf, Western B722+T7ULF trims 37.5% under federal 1.6 gpf caps; #165 of 3,875 rated single-flush models; most water-efficient 12.8% of 3,875 rated single-flush models, lower-flow than 87.2% of rated single-flush models (0.28 gpf lower-flow than the 1.28 gpf median). Bowl B722 / Tank T7ULF.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.0 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: Western holds 7 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~13,689 gallons/yr—roughly $110/yr in low-tariff towns ($8/1k gal), $151/yr at national averages ($11/1k gal), or $246/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Glendale Environmental Resources Department (AZ) list active rebates among 200 U.S. programs. Closest alternatives: Abath KBF-TPT001 (1.0 gpf) and American Standard 238AA115 (1.0 gpf).

Where does Western B722+T7ULF sit on the EPA WaterSense toilet flow curve?

Comparing Western B722+T7ULF (1.00 gpf) against federal EPAct (1.6 gpf) and legacy (3.5 gpf) baselines shows immediate per-use conservation.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): B722+T7ULF: 1.00; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)B722+T7ULF: 1.00B722+T7ULF1.00EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 1.0 gpf: 1 gpf (13th percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf1.0 gpf: 1 gpf (P13)

How do subfloor levelness and rough-in height protect Western B722+T7ULF?

Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What official WaterSense figures verify Western B722+T7ULF?

Examine Western B722+T7ULF certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Western (7 certified) EPA WaterSense Partner
Model Number / Series B722+T7ULF Certified Series (1 finish variants)
Rated Consumption 1.0 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Gravity Verify rough-in & supply pressure

What annual utility savings does Western B722+T7ULF deliver?

Compare 1-to-4-person household water use with Western B722+T7ULF against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.

Computed annual water savings for Western B722+T7ULF (1.0 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,825 gal1,095 gal4,563 gal (~$50)
2 Occupants3,650 gal2,190 gal9,126 gal (~$100)
3 Occupants5,475 gal3,285 gal13,689 gal (~$110–$246)
4 Occupants7,300 gal4,380 gal18,252 gal (~$201)

What alternative WaterSense models compare to Western B722+T7ULF?

Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
Abath KBF-TPT001 1.0 gpf (Same flow) Single / Gravity
American Standard 238AA115 1.0 gpf (Same flow) Single / Gravity
American Standard 2548A100 1.0 gpf (Same flow) Single / Pressure Assist
American Standard 740AA101 1.0 gpf (Same flow) Single / Gravity
AXENT R60-E 1.0 gpf (Same flow) Single / Pressure Assist

What will Western B722+T7ULF save on your annual water bill?

Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.

Which bath layouts should avoid specifying Western B722+T7ULF?

Match Western B722+T7ULF directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Building drain lacks 1/4 in/ft slope for reduced flush carry

Best-Fit Homeowner Profiles

  • Best for: Meeting 1.6 gpf federal & stricter WaterSense caps
  • Optimal use: Targeting ~$151/yr utility savings (3-person home)

Which homeowner questions come up most for Western B722+T7ULF?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Western B722+T7ULF.

Are older sewer lines safe for Western B722+T7ULF's 1.0 gpf flush volume?

Most copper/PVC lines handle 1.0 gpf cleanly, whereas sagging or scaled cast-iron laterals lacking 1/4 in/ft slope should be scoped prior to replacing 3.5 gpf bowls.

Does Western B722+T7ULF qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes Western B722+T7ULF eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does Western B722+T7ULF rank against other certified toilets?

Rated at 1.0 gpf, Western B722+T7ULF measures below the 1.28 gpf WaterSense toilet median across thousands of EPA-listed residential fixtures.

Does Western B722+T7ULF cut utility costs noticeably for a 3-person household?

Yes: cutting 13,686 gallons/yr relative to 3.5 gpf hardware translates to ~$151/yr in combined water/sewer savings at $11/1k gal.

What closet flange and side-wall clearances apply to Western B722+T7ULF?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 1.0 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing Western B722+T7ULF require a municipal plumbing permit?

Like-for-like swaps using Western B722+T7ULF on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How does Western B722+T7ULF cut household water draw versus 1992 federal rules?

Delivering 1.0 gpf, Western B722+T7ULF trims 1,095 gal/person/yr below 1.6 gpf EPAct caps (37.5% reduction) and 4,562 gal/person/yr under 3.5 gpf legacy fixtures.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories