Air King BFC90H Exhaust Fan Specifications

ENERGY STAR PD #2305727 · Bathroom/Utility Room · Qualified 2017-10-27
Verified Specification Summary

In EPA dataset 8dv7-nngq, Air King BFC90H tests at 90 CFM free discharge (75.6 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 4.7 CFM/W efficacy, meeting residential IRC M1505 sizing up to 75 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King BFC90H Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
90 / 75.6 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
4.7 CFM/W (#545/1,145)
Static Retention
84.0% @ 0.25"
Motor Draw
19.1 W (7.0 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Air King BFC90H vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 90 CFM open-air to 75.6 CFM at 0.25 in. w.g. (84.0% retention, 3.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Air King maintains 62 active ENERGY STAR blowers; BFC90H (series: Air King) (PD #2305727) gained qualification on 2017-10-27. Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 19.1 watts, about 7.0 kWh/yr (~$1.12/yr at $0.16/kWh) for 1 hr/day shower timers or 167.3 kWh/yr (~$26.77/yr) continuously. Closest competing matches include Good Housekeeping 84005 (100.0 CFM) and Broan AE100B = A000HFKT with AE100BF1 (100.0 CFM).

Does Air King BFC90H fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Air King BFC90H at 1.0 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Why avoid unvented attic termination with Air King BFC90H?

Under ASHRAE 62.2 best practice, Air King BFC90H needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Air King BFC90H?

Before cutting ceiling drywall or sizing attic transitions for Air King BFC90H, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Air King (62 models) ENERGY STAR Certified Partner
Model Number & Series BFC90H / Air King PD ID 2305727 (Qualified 2017-10-27)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (75.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Air King BFC90H?

Bathroom ventilation sizing below maps Air King BFC90H motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Air King BFC90H
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 75 sq ft1 CFM/sq ft @ 75.6 CFM
Tall Bath (9-ft Ceiling)Up to 67 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 25 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.0 kWh/yr (~$1.12/yr)19.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2167.3 kWh/yr (~$26.77/yr)19.1 W x 8,760 hrs / 1,000

What peer models sit nearest Air King BFC90H in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Air King BFC90H.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Good Housekeeping 84005 100 / 92.3 CFM 1.0 sones (Same) 4.5 CFM/W 4 in. diameter
Broan AE100B = A000HFKT with AE100BF1 100 / 95.5 CFM 1.0 sones (Same) 4.3 CFM/W 4 in. diameter
Broan AE100B = A000HFNF with AE100BF1 100 / 95.5 CFM 1.0 sones (Same) 4.3 CFM/W 4 in. diameter
Panasonic FV-08VRE2 80 / 66.7 CFM 1.0 sones (Same) 4.3 CFM/W 4 in. diameter
HomeWerks Worldwide 7117-01-BN 80 / 65.4 CFM 1.1 sones (+0.10) 4.6 CFM/W 4 in. diameter

What percentage of room demand does Air King BFC90H cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Air King BFC90H tested delivery.

Where should contractors skip Air King BFC90H on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Air King BFC90H carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 75.6 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Choose this if: Target comfort around 1.0 sones up to 75 sq ft
  • Works well for: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Air King BFC90H?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Air King BFC90H.

How much power does Air King BFC90H consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Air King BFC90H draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Air King BFC90H pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King BFC90H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Air King BFC90H?

Air King BFC90H features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Air King BFC90H's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King BFC90H's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Air King BFC90H score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Air King BFC90H delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Air King BFC90H?

Rule out Air King BFC90H when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Air King BFC90H capacity?

Because static drag at 0.25 in. w.g. lowers Air King BFC90H from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Air King BFC90H compared with a standard 3.0 sone builder fan?

Tested at 1.0 sones, Air King BFC90H operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)