Skip to main content
Grant Estimator

ACIQ AP80 Exhaust Fan Specifications

ENERGY STAR PD #3629723 · Bathroom/Utility Room · Qualified 2024-09-27
Verified Specification Summary

Homeowners specifying ACIQ AP80 gain 80 CFM at 0.1 in. w.g. (71.6 CFM at 0.25 in. w.g.) where it registers #265 of 607 in quietness (1.0 sones) and delivers 3.6 CFM/W efficacy, venting bathrooms up to 71 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside ACIQ AP80 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 71.6 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
3.6 CFM/W (#1,017/1,145)
Static Retention
89.5% @ 0.25"
Motor Draw
22.2 W (8.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does ACIQ AP80 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 71.6 CFM out of 80 CFM (89.5% retention, 1.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms ACIQ AP80 (series: AP) under PD #3629723 (15 models registered, 2024-09-27). Lighting kit: No. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.2 watts, about 8.1 kWh/yr (~$1.30/yr at $0.16/kWh) for 1 hr/day shower timers or 194.5 kWh/yr (~$31.12/yr) continuously. Closest competing matches include Canarm CP80 (80.0 CFM) and Cyclone CT80 (80.0 CFM).

What acoustic percentile does ACIQ AP80 occupy among 1,145 bath blowers?

Inspect how ACIQ AP80 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Which exterior damper path suits ACIQ AP80 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around ACIQ AP80 housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do ACIQ AP80 acoustic and static metrics stand?

Compare ACIQ AP80 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share ACIQ (15 models) ENERGY STAR Certified Partner
Model Number & Series AP80 / AP PD ID 3629723 (Qualified 2024-09-27)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (71.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can ACIQ AP80 handle taller ceilings or walk-in tub steam?

Evaluate how ACIQ AP80 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for ACIQ AP80
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 71 sq ft1 CFM/sq ft @ 71.6 CFM
Tall Bath (9-ft Ceiling)Up to 63 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 21 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.1 kWh/yr (~$1.30/yr)22.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2194.5 kWh/yr (~$31.12/yr)22.2 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near ACIQ AP80?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Canarm CP80 80 / 71.6 CFM 1.0 sones (Same) 3.6 CFM/W 4 in. diameter
Cyclone CT80 80 / 71.6 CFM 1.0 sones (Same) 3.6 CFM/W 4 in. diameter
Cyclone CTP80 80 / 71.6 CFM 1.0 sones (Same) 3.6 CFM/W 4 in. diameter
HomeWerks Worldwide 7117-02-BN 80 / 59.5 CFM 1.0 sones (Same) 3.6 CFM/W 4 in. diameter
HomeWerks Worldwide 7117-02-HW 80 / 59.5 CFM 1.0 sones (Same) 3.6 CFM/W 4 in. diameter

Is ACIQ AP80 sized right for your shower or tub room?

Check whether ACIQ AP80 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Who should not install ACIQ AP80 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting ACIQ AP80 for residential use.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 21 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Ideal fit: Moisture load fits 71.6 CFM net static output
  • Primary match: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for ACIQ AP80?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to ACIQ AP80.

Does ACIQ AP80 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), ACIQ AP80 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is ACIQ AP80 undersized or poorly matched for a bath renovation?

Skip ACIQ AP80 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check ACIQ AP80 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, ACIQ AP80 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does ACIQ AP80 sound output compare to noisy contractor-grade fans?

Rated at 1.0 sones, ACIQ AP80 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define ACIQ AP80?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can ACIQ AP80 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from ACIQ AP80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing ACIQ AP80?

ACIQ AP80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change ACIQ AP80's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing ACIQ AP80's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories