The Canarm CP80 (CP80) moves 80 CFM at 0.1 in. w.g. (71.6 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones), and delivers 3.6 CFM/W efficacy, sizing bathrooms up to 71 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Canarm CP80 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 71.6 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 3.6 CFM/W (#1,017/1,145)
- Static Retention
- 89.5% @ 0.25"
- Motor Draw
- 22.2 W (8.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Canarm CP80 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 71.6 CFM out of 80 CFM (89.5% retention, 1.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Canarm registers 5 certified models, with SKU CP80 (series: CP80) (PD #4510679) certified since 2025-09-05. Lighting kit: No. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.2 watts, about 8.1 kWh/yr (~$1.30/yr at $0.16/kWh) for 1 hr/day shower timers or 194.5 kWh/yr (~$31.12/yr) continuously. Closest competing matches include ACIQ AP80 (80.0 CFM) and Cyclone CT80 (80.0 CFM).
Where does Canarm CP80 sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.0 sones against all 1,145 EPA listings.
How does duct geometry alter Canarm CP80 static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Canarm CP80?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Canarm CP80 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Canarm (5 models) | ENERGY STAR Certified Partner |
| Model Number & Series | CP80 / CP80 | PD ID 4510679 (Qualified 2025-09-05) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (71.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Canarm CP80 ventilate safely?
Sizing outputs below convert Canarm CP80 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 71 sq ft | 1 CFM/sq ft @ 71.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 21 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.1 kWh/yr (~$1.30/yr) | 22.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 194.5 kWh/yr (~$31.12/yr) | 22.2 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Canarm CP80 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AP80 | 80 / 71.6 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| Cyclone CT80 | 80 / 71.6 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| Cyclone CTP80 | 80 / 71.6 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7117-02-BN | 80 / 59.5 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7117-02-HW | 80 / 59.5 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
Will Canarm CP80 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Canarm CP80 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Who should not install Canarm CP80 in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Canarm CP80 for residential use.
Limitations & Who Should Skip
- Steam or walk-in tub room > 21 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 71 sq ft with 8-ft ceilings (63 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Canarm CP80?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Canarm CP80.
Does Canarm CP80 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Canarm CP80 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Canarm CP80 undersized or poorly matched for a bath renovation?
Skip Canarm CP80 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Canarm CP80 CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Canarm CP80 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does Canarm CP80 sound output compare to noisy contractor-grade fans?
Rated at 1.0 sones, Canarm CP80 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Canarm CP80?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Canarm CP80 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Canarm CP80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Canarm CP80?
Canarm CP80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Canarm CP80's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Canarm CP80's safe coverage footprint from 50 sq ft to 44 sq ft.