Certified by EPA ENERGY STAR, HomeWerks Worldwide 7117-02-HW delivers 80 CFM free-air (59.5 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 3.6 CFM/W efficacy, clearing residential IRC M1505 sizing up to 59 sq ft (8-ft height) or 52 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside HomeWerks Worldwide 7117-02-HW Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 59.5 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 3.6 CFM/W (#1,017/1,145)
- Static Retention
- 74.4% @ 0.25"
- Motor Draw
- 22.2 W (8.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does HomeWerks Worldwide 7117-02-HW vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 59.5 CFM at 0.25 in. w.g. (74.4% retention, 13.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #4499053 verifies 7117-02-HW (series: 7117-02-HW) under HomeWerks Worldwide (31 listed models, qualified 2025-07-11). Lighting kit: Yes. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.2 watts, about 8.1 kWh/yr (~$1.30/yr at $0.16/kWh) for 1 hr/day shower timers or 194.5 kWh/yr (~$31.12/yr) continuously. Closest competing matches include ACIQ AP80 (80.0 CFM) and Canarm CP80 (80.0 CFM).
How noisy is HomeWerks Worldwide 7117-02-HW compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while HomeWerks Worldwide 7117-02-HW measures 1.0 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect HomeWerks Worldwide 7117-02-HW airflow?
Connecting HomeWerks Worldwide 7117-02-HW through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify HomeWerks Worldwide 7117-02-HW performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for HomeWerks Worldwide 7117-02-HW lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | HomeWerks Worldwide (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 7117-02-HW / 7117-02-HW | PD ID 4499053 (Qualified 2025-07-11) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (59.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What room sizes and annual power draw fit HomeWerks Worldwide 7117-02-HW?
Calculated coverage metrics translate HomeWerks Worldwide 7117-02-HW airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 59 sq ft | 1 CFM/sq ft @ 59.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 52 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.1 kWh/yr (~$1.30/yr) | 22.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 194.5 kWh/yr (~$31.12/yr) | 22.2 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to HomeWerks Worldwide 7117-02-HW?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AP80 | 80 / 71.6 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| Canarm CP80 | 80 / 71.6 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| Cyclone CT80 | 80 / 71.6 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| Cyclone CTP80 | 80 / 71.6 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| QuFresh BQ80 | 80 / 71.6 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
Does HomeWerks Worldwide 7117-02-HW match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check HomeWerks Worldwide 7117-02-HW percentage capacity without sending data.
Where should contractors skip HomeWerks Worldwide 7117-02-HW on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for HomeWerks Worldwide 7117-02-HW carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 59.5 CFM net static output
- Works well for: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for HomeWerks Worldwide 7117-02-HW?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around HomeWerks Worldwide 7117-02-HW.
How much power does HomeWerks Worldwide 7117-02-HW consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, HomeWerks Worldwide 7117-02-HW draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can HomeWerks Worldwide 7117-02-HW pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from HomeWerks Worldwide 7117-02-HW's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing HomeWerks Worldwide 7117-02-HW?
HomeWerks Worldwide 7117-02-HW features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change HomeWerks Worldwide 7117-02-HW's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing HomeWerks Worldwide 7117-02-HW's safe coverage footprint from 50 sq ft to 44 sq ft.
How does HomeWerks Worldwide 7117-02-HW score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), HomeWerks Worldwide 7117-02-HW delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify HomeWerks Worldwide 7117-02-HW?
Rule out HomeWerks Worldwide 7117-02-HW when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke HomeWerks Worldwide 7117-02-HW capacity?
Because static drag at 0.25 in. w.g. lowers HomeWerks Worldwide 7117-02-HW from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is HomeWerks Worldwide 7117-02-HW compared with a standard 3.0 sone builder fan?
Tested at 1.0 sones, HomeWerks Worldwide 7117-02-HW operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)