The Cyclone CTP80 (CTP) moves 80 CFM at 0.1 in. w.g. (71.6 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones), and delivers 3.6 CFM/W efficacy, sizing bathrooms up to 71 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Cyclone CTP80 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 71.6 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 3.6 CFM/W (#1,017/1,145)
- Static Retention
- 89.5% @ 0.25"
- Motor Draw
- 22.2 W (8.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Cyclone CTP80 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 71.6 CFM out of 80 CFM (89.5% retention, 1.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Cyclone maintains 17 active ENERGY STAR blowers; CTP80 (series: CTP) (PD #2409645) gained qualification on 2023-02-03. Lighting kit: No. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.2 watts, about 8.1 kWh/yr (~$1.30/yr at $0.16/kWh) for 1 hr/day shower timers or 194.5 kWh/yr (~$31.12/yr) continuously. Closest competing matches include ACIQ AP80 (80.0 CFM) and Canarm CP80 (80.0 CFM).
Where does Cyclone CTP80 sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.0 sones against all 1,145 EPA listings.
How does duct geometry alter Cyclone CTP80 static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Cyclone CTP80?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Cyclone CTP80 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Cyclone (17 models) | ENERGY STAR Certified Partner |
| Model Number & Series | CTP80 / CTP | PD ID 2409645 (Qualified 2023-02-03) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (71.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Cyclone CTP80 ventilate safely?
Sizing outputs below convert Cyclone CTP80 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 71 sq ft | 1 CFM/sq ft @ 71.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 21 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.1 kWh/yr (~$1.30/yr) | 22.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 194.5 kWh/yr (~$31.12/yr) | 22.2 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Cyclone CTP80 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AP80 | 80 / 71.6 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| Canarm CP80 | 80 / 71.6 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7117-02-BN | 80 / 59.5 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7117-02-HW | 80 / 59.5 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| QuFresh BQ80 | 80 / 71.6 CFM | 1.0 sones (Same) | 3.6 CFM/W | 4 in. diameter |
Will Cyclone CTP80 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Cyclone CTP80 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
When does Cyclone CTP80 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Cyclone CTP80.
Limitations & Who Should Skip
- Steam or walk-in tub room > 21 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 71 sq ft with 8-ft ceilings (63 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Cyclone CTP80?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Cyclone CTP80.
How much airflow does Cyclone CTP80 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Cyclone CTP80 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Cyclone CTP80 disturb adjacent bedrooms during night use?
Acoustic measurement places Cyclone CTP80 at 1.0 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.
Does running Cyclone CTP80 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Cyclone CTP80 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Cyclone CTP80 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Cyclone CTP80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Cyclone CTP80?
Cyclone CTP80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Cyclone CTP80's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Cyclone CTP80's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Cyclone CTP80 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Cyclone CTP80 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Cyclone CTP80?
Do not force Cyclone CTP80 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)