The Broan LP80=LP80HwithLP80F (N/A) moves 80 CFM at 0.1 in. w.g. (65.6 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones), and delivers 3.7 CFM/W efficacy, sizing bathrooms up to 65 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan LP80=LP80HwithLP80F Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 65.6 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 3.7 CFM/W (#987/1,145)
- Static Retention
- 82.0% @ 0.25"
- Motor Draw
- 21.6 W (7.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan LP80=LP80HwithLP80F vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 65.6 CFM at 0.25 in. w.g. (82.0% retention, 5.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Broan registers 207 certified models, with SKU LP80=LP80HwithLP80F (series: N/A) (PD #2248912) certified since 2015-10-01. Lighting kit: No. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.6 watts, about 7.9 kWh/yr (~$1.26/yr at $0.16/kWh) for 1 hr/day shower timers or 189.2 kWh/yr (~$30.27/yr) continuously. Closest competing matches include Nutone LPN80=LP80HwithLPN80F (80.0 CFM) and Air King AK80H (80.0 CFM).
Where does Broan LP80=LP80HwithLP80F sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.0 sones against all 1,145 EPA listings.
How does duct geometry alter Broan LP80=LP80HwithLP80F static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Broan LP80=LP80HwithLP80F?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan LP80=LP80HwithLP80F alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | LP80=LP80HwithLP80F / N/A | PD ID 2248912 (Qualified 2015-10-01) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (65.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Broan LP80=LP80HwithLP80F ventilate safely?
Sizing outputs below convert Broan LP80=LP80HwithLP80F tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 65 sq ft | 1 CFM/sq ft @ 65.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 58 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.9 kWh/yr (~$1.26/yr) | 21.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 189.2 kWh/yr (~$30.27/yr) | 21.6 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Broan LP80=LP80HwithLP80F closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Nutone LPN80=LP80HwithLPN80F | 80 / 65.6 CFM | 1.0 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| Air King AK80H | 80 / 71.4 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| Air King AK80LS1 | 80 / 71.4 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| Air King FR80 | 80 / 71.4 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| Air King FR80H | 80 / 71.4 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
Will Broan LP80=LP80HwithLP80F clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Broan LP80=LP80HwithLP80F satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Which bath layouts should avoid specifying Broan LP80=LP80HwithLP80F?
Match Broan LP80=LP80HwithLP80F directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Best for: Bathroom floor <= 65 sq ft with 8-ft ceilings (58 sq ft at 9-ft height)
- Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Broan LP80=LP80HwithLP80F?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan LP80=LP80HwithLP80F.
Where does Broan LP80=LP80HwithLP80F sit on acoustic comfort for senior homeowners?
Measuring 1.0 sones, Broan LP80=LP80HwithLP80F operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Broan LP80=LP80HwithLP80F cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Broan LP80=LP80HwithLP80F 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Broan LP80=LP80HwithLP80F pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan LP80=LP80HwithLP80F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan LP80=LP80HwithLP80F?
Broan LP80=LP80HwithLP80F features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan LP80=LP80HwithLP80F's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan LP80=LP80HwithLP80F's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Broan LP80=LP80HwithLP80F ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan LP80=LP80HwithLP80F covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Broan LP80=LP80HwithLP80F run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan LP80=LP80HwithLP80F.
What happens to Broan LP80=LP80HwithLP80F CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Broan LP80=LP80HwithLP80F moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)