Certified by EPA ENERGY STAR, Akicon AK13110N4-W delivers 110 CFM free-air (87.4 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 4.2 CFM/W efficacy, clearing residential IRC M1505 sizing up to 87 sq ft (8-ft height) or 77 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Akicon AK13110N4-W Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 87.4 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 4.2 CFM/W (#774/1,145)
- Static Retention
- 79.5% @ 0.25"
- Motor Draw
- 26.2 W (9.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Akicon AK13110N4-W vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 87.4 CFM at 0.25 in. w.g. (79.5% retention, 8.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Akicon's 14-unit lineup, AK13110N4-W (series: AK13110N4-W) carries PD #3624234 dating to 2024-08-02. Lighting kit: Yes. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.2 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 229.5 kWh/yr (~$36.72/yr) continuously. Closest competing matches include Broan-Nutone PCPE811 (110.0 CFM) and Broan-Nutone PCPE811K (110.0 CFM).
How noisy is Akicon AK13110N4-W compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Akicon AK13110N4-W measures 2.0 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect Akicon AK13110N4-W airflow?
Connecting Akicon AK13110N4-W through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Akicon AK13110N4-W performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Akicon AK13110N4-W lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Akicon (14 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AK13110N4-W / AK13110N4-W | PD ID 3624234 (Qualified 2024-08-02) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (87.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What room sizes and annual power draw fit Akicon AK13110N4-W?
Calculated coverage metrics translate Akicon AK13110N4-W airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 87 sq ft | 1 CFM/sq ft @ 87.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 77 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 37 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.6 kWh/yr (~$1.54/yr) | 26.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 229.5 kWh/yr (~$36.72/yr) | 26.2 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Akicon AK13110N4-W?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan-Nutone PCPE811 | 110 / 94.1 CFM | Unpublished | 4.2 CFM/W | 4 in. diameter |
| Broan-Nutone PCPE811K | 110 / 94.1 CFM | Unpublished | 4.2 CFM/W | 4 in. diameter |
| Broan-Nutone PCPE811K = PCPE811H with PCPE811KF | 110 / 94.1 CFM | Unpublished | 4.2 CFM/W | 4 in. diameter |
| Broan-Nutone PCPER811 | 110 / 94.1 CFM | Unpublished | 4.2 CFM/W | 4 in. diameter |
| Broan-Nutone PCPER811 = PCPE811H with PCPER811F | 110 / 94.1 CFM | Unpublished | 4.2 CFM/W | 4 in. diameter |
Does Akicon AK13110N4-W match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Akicon AK13110N4-W percentage capacity without sending data.
Where should contractors skip Akicon AK13110N4-W on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Akicon AK13110N4-W carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 37 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 87.4 CFM net static output
- Works well for: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Akicon AK13110N4-W?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Akicon AK13110N4-W.
Will long attic ducting choke Akicon AK13110N4-W capacity?
Because static drag at 0.25 in. w.g. lowers Akicon AK13110N4-W from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Akicon AK13110N4-W compared with a standard 3.0 sone builder fan?
Tested at 2.0 sones, Akicon AK13110N4-W produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Akicon AK13110N4-W consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Akicon AK13110N4-W draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Akicon AK13110N4-W pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Akicon AK13110N4-W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Akicon AK13110N4-W?
Akicon AK13110N4-W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Akicon AK13110N4-W's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Akicon AK13110N4-W's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Akicon AK13110N4-W score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Akicon AK13110N4-W delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Akicon AK13110N4-W?
Rule out Akicon AK13110N4-W when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)