Homeowners specifying Broan-Nutone PCPER811 = PCPE811H with PCPER811F gain 110 CFM at 0.1 in. w.g. (94.1 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 4.2 CFM/W efficacy, venting bathrooms up to 94 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone PCPER811 = PCPE811H with PCPER811F before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 94.1 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.2 CFM/W (#774/1,145)
- Static Retention
- 85.5% @ 0.25"
- Motor Draw
- 26.2 W (9.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan-Nutone PCPER811 = PCPE811H with PCPER811F vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan-Nutone PCPER811 = PCPE811H with PCPER811F (EPA filing PD #4481304) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 94.1 CFM out of 110 CFM (85.5% retention, 2.2 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places PCPER811 = PCPE811H with PCPER811F (series: FLEX SERIES) (PD #4481304) among 48 Broan-Nutone entries qualified through 2025-07-25. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.2 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 229.5 kWh/yr (~$36.72/yr) continuously. Closest competing matches include Broan AER110LTMB (110.0 CFM) and Broan AER110LTW (110.0 CFM).
Which exterior damper path suits Broan-Nutone PCPER811 = PCPE811H with PCPER811F best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Broan-Nutone PCPER811 = PCPE811H with PCPER811F housings.
Where do Broan-Nutone PCPER811 = PCPE811H with PCPER811F acoustic and static metrics stand?
Compare Broan-Nutone PCPER811 = PCPE811H with PCPER811F published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PCPER811 = PCPE811H with PCPER811F / FLEX SERIES | PD ID 4481304 (Qualified 2025-07-25) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (94.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can Broan-Nutone PCPER811 = PCPE811H with PCPER811F handle taller ceilings or walk-in tub steam?
Evaluate how Broan-Nutone PCPER811 = PCPE811H with PCPER811F scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 94 sq ft | 1 CFM/sq ft @ 94.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 83 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 44 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.6 kWh/yr (~$1.54/yr) | 26.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 229.5 kWh/yr (~$36.72/yr) | 26.2 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Broan-Nutone PCPER811 = PCPE811H with PCPER811F?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan AER110LTMB | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Broan AER110LTW | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Nutone AER110SLW | 110 / 89.5 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Nutone AERN110LTK | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Nutone AERN110LTW | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
Is Broan-Nutone PCPER811 = PCPE811H with PCPER811F sized right for your shower or tub room?
Check whether Broan-Nutone PCPER811 = PCPE811H with PCPER811F clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Who should not install Broan-Nutone PCPER811 = PCPE811H with PCPE in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan-Nutone PCPER811 = PCPE811H with PCPE for residential use.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 44 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Ideal fit: Moisture load fits 94.1 CFM net static output
- Primary match: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Broan-Nutone PCPER811 = PCPE811H with PCPER811F?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan-Nutone PCPER811 = PCPE811H with PCPER811F.
How does Broan-Nutone PCPER811 = PCPE811H with PCPER811F sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, Broan-Nutone PCPER811 = PCPE811H with PCPER811F produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Broan-Nutone PCPER811 = PCPE811H with PCPER811F?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Broan-Nutone PCPER811 = PCPE811H with PCPER811F pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone PCPER811 = PCPE811H with PCPER811F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan-Nutone PCPER811 = PCPE811H with PCPER811F?
Broan-Nutone PCPER811 = PCPE811H with PCPER811F features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan-Nutone PCPER811 = PCPE811H with PCPER811F's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone PCPER811 = PCPE811H with PCPER811F's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Broan-Nutone PCPER811 = PCPE811H with PCPER811F satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone PCPER811 = PCPE811H with PCPER811F clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Broan-Nutone PCPER811 = PCPE811H with PCPER811F undersized or poorly matched for a bath renovation?
Skip Broan-Nutone PCPER811 = PCPE811H with PCPER811F if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Broan-Nutone PCPER811 = PCPE811H with PCPER811F CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan-Nutone PCPER811 = PCPE811H with PCPER811F registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)