Rated for 110 CFM open-air (94.1 CFM at 0.25 in. w.g.), Broan-Nutone PCPE811K omits a published 0.1-inch sone rating and delivers 4.2 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 94 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone PCPE811K Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 94.1 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.2 CFM/W (#774/1,145)
- Static Retention
- 85.5% @ 0.25"
- Motor Draw
- 26.2 W (9.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan-Nutone PCPE811K vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan-Nutone PCPE811K (EPA filing PD #4481307) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 94.1 CFM out of 110 CFM (85.5% retention, 2.2 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Broan-Nutone PCPE811K (series: FLEX SERIES) under PD #4481307 (48 models registered, 2025-07-25). Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.2 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 229.5 kWh/yr (~$36.72/yr) continuously. Closest competing matches include Broan AER110LTMB (110.0 CFM) and Broan AER110LTW (110.0 CFM).
How do flex elbows choke Broan-Nutone PCPE811K at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Broan-Nutone PCPE811K moving full rated CFM.
Does Broan-Nutone PCPE811K meet residential exhaust fan code specs?
Inspect Broan-Nutone PCPE811K mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PCPE811K / FLEX SERIES | PD ID 4481307 (Qualified 2025-07-25) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (94.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Broan-Nutone PCPE811K airflow output?
Annual electricity figures and room square-footage ceilings below reflect Broan-Nutone PCPE811K tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 94 sq ft | 1 CFM/sq ft @ 94.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 83 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 44 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.6 kWh/yr (~$1.54/yr) | 26.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 229.5 kWh/yr (~$36.72/yr) | 26.2 W x 8,760 hrs / 1,000 |
Which competing models share Broan-Nutone PCPE811K airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan AER110LTMB | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Broan AER110LTW | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Nutone AER110SLW | 110 / 89.5 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Nutone AERN110LTK | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Nutone AERN110LTW | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
How much airflow margin does Broan-Nutone PCPE811K give your bath?
Run a quick local room-volume check for Broan-Nutone PCPE811K by entering square footage and ceiling height to spot under-vented steam risks early.
Does Broan-Nutone PCPE811K suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan-Nutone PCPE811K for your remodel.
Limitations & Who Should Skip
- Steam or walk-in tub room > 44 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 94 sq ft with 8-ft ceilings (83 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Broan-Nutone PCPE811K?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan-Nutone PCPE811K.
Who should NOT install Broan-Nutone PCPE811K in a bathroom remodel?
Avoid specifying Broan-Nutone PCPE811K in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Broan-Nutone PCPE811K airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan-Nutone PCPE811K achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Broan-Nutone PCPE811K occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., Broan-Nutone PCPE811K produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does Broan-Nutone PCPE811K add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Broan-Nutone PCPE811K averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Broan-Nutone PCPE811K pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone PCPE811K's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan-Nutone PCPE811K?
Broan-Nutone PCPE811K features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan-Nutone PCPE811K's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone PCPE811K's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Broan-Nutone PCPE811K pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone PCPE811K easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)