Skip to main content
Grant Estimator

Broan-Nutone PCPE811K Exhaust Fan Specifications

ENERGY STAR PD #4481307 · Bathroom/Utility Room · Qualified 2025-07-25
Verified Specification Summary

Rated for 110 CFM open-air (94.1 CFM at 0.25 in. w.g.), Broan-Nutone PCPE811K omits a published 0.1-inch sone rating and delivers 4.2 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 94 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone PCPE811K Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 94.1 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.2 CFM/W (#774/1,145)
Static Retention
85.5% @ 0.25"
Motor Draw
26.2 W (9.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan-Nutone PCPE811K vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan-Nutone PCPE811K (EPA filing PD #4481307) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 94.1 CFM out of 110 CFM (85.5% retention, 2.2 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Broan-Nutone PCPE811K (series: FLEX SERIES) under PD #4481307 (48 models registered, 2025-07-25). Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.2 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 229.5 kWh/yr (~$36.72/yr) continuously. Closest competing matches include Broan AER110LTMB (110.0 CFM) and Broan AER110LTW (110.0 CFM).

How do flex elbows choke Broan-Nutone PCPE811K at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Broan-Nutone PCPE811K moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Broan-Nutone PCPE811K meet residential exhaust fan code specs?

Inspect Broan-Nutone PCPE811K mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan-Nutone (48 models) ENERGY STAR Certified Partner
Model Number & Series PCPE811K / FLEX SERIES PD ID 4481307 (Qualified 2025-07-25)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (94.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Broan-Nutone PCPE811K airflow output?

Annual electricity figures and room square-footage ceilings below reflect Broan-Nutone PCPE811K tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Broan-Nutone PCPE811K
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 94 sq ft1 CFM/sq ft @ 94.1 CFM
Tall Bath (9-ft Ceiling)Up to 83 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 44 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.6 kWh/yr (~$1.54/yr)26.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2229.5 kWh/yr (~$36.72/yr)26.2 W x 8,760 hrs / 1,000

Which competing models share Broan-Nutone PCPE811K airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan AER110LTMB 110 / 89.9 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Broan AER110LTW 110 / 89.9 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Nutone AER110SLW 110 / 89.5 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Nutone AERN110LTK 110 / 89.9 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Nutone AERN110LTW 110 / 89.9 CFM 1.5 sones 4.2 CFM/W 4 in. diameter

How much airflow margin does Broan-Nutone PCPE811K give your bath?

Run a quick local room-volume check for Broan-Nutone PCPE811K by entering square footage and ceiling height to spot under-vented steam risks early.

Does Broan-Nutone PCPE811K suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan-Nutone PCPE811K for your remodel.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 44 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 94 sq ft with 8-ft ceilings (83 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Broan-Nutone PCPE811K?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan-Nutone PCPE811K.

Who should NOT install Broan-Nutone PCPE811K in a bathroom remodel?

Avoid specifying Broan-Nutone PCPE811K in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Broan-Nutone PCPE811K airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan-Nutone PCPE811K achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Broan-Nutone PCPE811K occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Broan-Nutone PCPE811K produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Broan-Nutone PCPE811K add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan-Nutone PCPE811K averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Broan-Nutone PCPE811K pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone PCPE811K's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan-Nutone PCPE811K?

Broan-Nutone PCPE811K features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan-Nutone PCPE811K's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone PCPE811K's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan-Nutone PCPE811K pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone PCPE811K easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories