Skip to main content
Grant Estimator

Best HBN560212SS Exhaust Fan Specifications

ENERGY STAR PD #3998917 · Range Hood · Qualified 2025-02-21
Verified Specification Summary

Tested under HVI protocols, the Best HBN560212SS exhaust unit achieves 200 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), registers #1 of 607 in quietness (0.0 sones) and delivers 16.6 CFM/W efficacy, covering standard baths up to 200 sq ft on a 10 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Best HBN560212SS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
200 / N/A CFM
Noise @ 0.1"
0.0 sones (#1/607)
Efficacy Rank
16.6 CFM/W (#4/1,145)
Static Retention
0.1" test only
Motor Draw
12.0 W (4.4 kWh/yr)
Duct & Tier
10 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Best HBN560212SS vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.0 sones (#1 of 607 rated models, quietest 1.5% of 607 rated models, quieter than 98.5% of rated models, 1.00 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Free-discharge delivery reaches 200 CFM (#45 of 1,145 certified models) via a 10 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 10 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #3998917 verifies HBN560212SS (series: RANGE HOOD) under Best (17 listed models, qualified 2025-02-21). Lighting kit: Yes. At 16.6 CFM/W (#4 of 1,145, top 1.0% of 1,145 rated models, more efficient than 99.0% of rated models, 11.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.0 watts, about 4.4 kWh/yr (~$0.70/yr at $0.16/kWh) for 1 hr/day shower timers or 105.1 kWh/yr (~$16.82/yr) continuously. Closest competing matches include Best HBN536212SS (200.0 CFM) and Best HBN536912SS (200.0 CFM).

Where do Best HBN560212SS sones rank across EPA ENERGY STAR fans?

Comparing Best HBN560212SS (0.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.0 sone: 0 sones (1st percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.0 sone: 0 sones (P1)

What attic duct routing preserves Best HBN560212SS CFM output?

Short straight 10 in. diameter duct paths retain up to ~82% of open-air capacity on Best HBN560212SS, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Best HBN560212SS measure up on airflow and noise ratings?

Each row below breaks down Best HBN560212SS certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Best (17 models) ENERGY STAR Certified Partner
Model Number & Series HBN560212SS / RANGE HOOD PD ID 3998917 (Qualified 2025-02-21)
Duct Connection 10 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (200 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.0 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Best HBN560212SS CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Best HBN560212SS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 200 sq ft1 CFM/sq ft @ 200 CFM
Tall Bath (9-ft Ceiling)Up to 177 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 150 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.4 kWh/yr (~$0.70/yr)12.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2105.1 kWh/yr (~$16.82/yr)12.0 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Best HBN560212SS?

Compare Best HBN560212SS side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Best HBN536212SS 200 / N/A CFM 0.0 sones (Same) 16.6 CFM/W 10 in. diameter
Best HBN536912SS 200 / N/A CFM 0.0 sones (Same) 16.6 CFM/W 10 in. diameter
Best HBN542912SS 200 / N/A CFM 0.0 sones (Same) 16.6 CFM/W 10 in. diameter
Best HBN548212SS 200 / N/A CFM 0.0 sones (Same) 16.6 CFM/W 10 in. diameter
Best HBN548912SS 200 / N/A CFM 0.0 sones (Same) 16.6 CFM/W 10 in. diameter

Can you size Best HBN560212SS for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Best HBN560212SS verified capacity.

Which bath layouts should avoid specifying Best HBN560212SS?

Match Best HBN560212SS directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 200 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around 0.0 sones up to 200 sq ft
  • Optimal use: Paired with rigid galvanized 10 in. diameter transition

How do federal and code standards apply to Best HBN560212SS?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Best HBN560212SS.

Where does Best HBN560212SS sit on acoustic comfort for senior homeowners?

Measuring 0.0 sones, Best HBN560212SS operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Best HBN560212SS cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Best HBN560212SS 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Best HBN560212SS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Best HBN560212SS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Best HBN560212SS?

Best HBN560212SS features a 10 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Best HBN560212SS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Best HBN560212SS's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Best HBN560212SS ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Best HBN560212SS covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Best HBN560212SS run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Best HBN560212SS.

What happens to Best HBN560212SS CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Best HBN560212SS moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 10 in. diameter collar.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories