Skip to main content
Grant Estimator

Best HBN566212SS Exhaust Fan Specifications

ENERGY STAR PD #3998918 · Range Hood · Qualified 2025-02-21
Verified Specification Summary

Rated for 200 CFM open-air (unpublished 0.25 in. w.g. output), Best HBN566212SS registers #1 of 607 in quietness (0.0 sones) and delivers 16.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 200 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Best HBN566212SS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
200 / N/A CFM
Noise @ 0.1"
0.0 sones (#1/607)
Efficacy Rank
16.6 CFM/W (#4/1,145)
Static Retention
0.1" test only
Motor Draw
12.0 W (4.4 kWh/yr)
Duct & Tier
10 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Best HBN566212SS vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.0 sones (#1 of 607 rated models, quietest 1.5% of 607 rated models, quieter than 98.5% of rated models, 1.00 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Free-discharge delivery reaches 200 CFM (#45 of 1,145 certified models) via a 10 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 10 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #3998918 verifies HBN566212SS (series: RANGE HOOD) under Best (17 listed models, qualified 2025-02-21). Lighting kit: Yes. At 16.6 CFM/W (#4 of 1,145, top 1.0% of 1,145 rated models, more efficient than 99.0% of rated models, 11.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.0 watts, about 4.4 kWh/yr (~$0.70/yr at $0.16/kWh) for 1 hr/day shower timers or 105.1 kWh/yr (~$16.82/yr) continuously. Closest competing matches include Best HBN536212SS (200.0 CFM) and Best HBN536912SS (200.0 CFM).

How does Best HBN566212SS acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Best HBN566212SS (0.0 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.0 sone: 0 sones (1st percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.0 sone: 0 sones (P1)

How do flex elbows choke Best HBN566212SS at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 10 in. diameter metal pipe keeps Best HBN566212SS moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Best HBN566212SS meet residential exhaust fan code specs?

Inspect Best HBN566212SS mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Best (17 models) ENERGY STAR Certified Partner
Model Number & Series HBN566212SS / RANGE HOOD PD ID 3998918 (Qualified 2025-02-21)
Duct Connection 10 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (200 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.0 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Best HBN566212SS airflow output?

Annual electricity figures and room square-footage ceilings below reflect Best HBN566212SS tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Best HBN566212SS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 200 sq ft1 CFM/sq ft @ 200 CFM
Tall Bath (9-ft Ceiling)Up to 177 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 150 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.4 kWh/yr (~$0.70/yr)12.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2105.1 kWh/yr (~$16.82/yr)12.0 W x 8,760 hrs / 1,000

Which competing models share Best HBN566212SS airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Best HBN536212SS 200 / N/A CFM 0.0 sones (Same) 16.6 CFM/W 10 in. diameter
Best HBN536912SS 200 / N/A CFM 0.0 sones (Same) 16.6 CFM/W 10 in. diameter
Best HBN542912SS 200 / N/A CFM 0.0 sones (Same) 16.6 CFM/W 10 in. diameter
Best HBN548212SS 200 / N/A CFM 0.0 sones (Same) 16.6 CFM/W 10 in. diameter
Best HBN548912SS 200 / N/A CFM 0.0 sones (Same) 16.6 CFM/W 10 in. diameter

How much airflow margin does Best HBN566212SS give your bath?

Run a quick local room-volume check for Best HBN566212SS by entering square footage and ceiling height to spot under-vented steam risks early.

Which bath layouts should avoid specifying Best HBN566212SS?

Match Best HBN566212SS directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 150 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Best for: Bathroom floor <= 200 sq ft with 8-ft ceilings (177 sq ft at 9-ft height)
  • Optimal use: Exterior run uses smooth rigid metal matched to 10 in. diameter

What should homeowners verify first about Best HBN566212SS?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Best HBN566212SS.

What bathroom square footage can Best HBN566212SS ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Best HBN566212SS covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Best HBN566212SS run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Best HBN566212SS.

What happens to Best HBN566212SS CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Best HBN566212SS moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 10 in. diameter collar.

Where does Best HBN566212SS sit on acoustic comfort for senior homeowners?

Measuring 0.0 sones, Best HBN566212SS operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Best HBN566212SS cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Best HBN566212SS 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Best HBN566212SS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Best HBN566212SS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Best HBN566212SS?

Best HBN566212SS features a 10 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Best HBN566212SS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Best HBN566212SS's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories