Homeowners specifying Broan AE80K gain 80 CFM at 0.1 in. w.g. (70.6 CFM at 0.25 in. w.g.) where it registers #135 of 607 in quietness (0.7 sones) and delivers 3.9 CFM/W efficacy, venting bathrooms up to 70 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80K Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 70.6 CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 88.2% @ 0.25"
- Motor Draw
- 20.5 W (7.5 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan AE80K vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 70.6 CFM out of 80 CFM (88.2% retention, 0.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Broan maintains 207 active ENERGY STAR blowers; AE80K (series: INVENT) (PD #2369229) gained qualification on 2020-11-06. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.5 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 179.6 kWh/yr (~$28.74/yr) continuously. Closest competing matches include ACIQ AEP80 (80.0 CFM) and Canarm CEP80 (80.0 CFM).
What acoustic percentile does Broan AE80K occupy among 1,145 bath blowers?
Inspect how Broan AE80K positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Broan AE80K best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Broan AE80K housings.
Where do Broan AE80K acoustic and static metrics stand?
Compare Broan AE80K published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AE80K / INVENT | PD ID 2369229 (Qualified 2020-11-06) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (70.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can Broan AE80K handle taller ceilings or walk-in tub steam?
Evaluate how Broan AE80K scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 70 sq ft | 1 CFM/sq ft @ 70.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 62 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 20 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.5 kWh/yr (~$1.20/yr) | 20.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 179.6 kWh/yr (~$28.74/yr) | 20.5 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Broan AE80K?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AEP80 | 80 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| Canarm CEP80 | 80 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| Cyclone ESCBP80 | 80 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| Revent RVPR80 | 80 / 66.2 CFM | 0.7 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Ortech ODE-8007 | 80 / 69.8 CFM | 0.7 sones (Same) | 4.3 CFM/W | 4 in. diameter |
Is Broan AE80K sized right for your shower or tub room?
Check whether Broan AE80K clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Which bath layouts should avoid specifying Broan AE80K?
Match Broan AE80K directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 20 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Best for: Moisture load fits 70.6 CFM net static output
- Optimal use: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Broan AE80K?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan AE80K.
What does Broan AE80K cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Broan AE80K 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Broan AE80K pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80K's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan AE80K?
Broan AE80K features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan AE80K's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80K's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Broan AE80K ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan AE80K covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Broan AE80K run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan AE80K.
What happens to Broan AE80K CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Broan AE80K moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Where does Broan AE80K sit on acoustic comfort for senior homeowners?
Measuring 0.7 sones, Broan AE80K operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)