Skip to main content
Grant Estimator

Broan AER110K Exhaust Fan Specifications

ENERGY STAR PD #4697334 · Bathroom/Utility Room · Qualified 2026-08-19
Verified Specification Summary

Homeowners specifying Broan AER110K gain 110 CFM at 0.1 in. w.g. (95.5 CFM at 0.25 in. w.g.) where it registers #265 of 607 in quietness (1.0 sones) and delivers 4.3 CFM/W efficacy, venting bathrooms up to 95 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AER110K Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 95.5 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
4.3 CFM/W (#718/1,145)
Static Retention
86.8% @ 0.25"
Motor Draw
25.6 W (9.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan AER110K vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 95.5 CFM out of 110 CFM (86.8% retention, 0.9 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Broan maintains 207 active ENERGY STAR blowers; AER110K (series: INVENT) (PD #4697334) gained qualification on 2026-08-19. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Amazon Basics B089R8S365 (110.0 CFM) and HomeWerks Worldwide 7107-03HW (110.0 CFM).

What acoustic percentile does Broan AER110K occupy among 1,145 bath blowers?

Inspect how Broan AER110K positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Which exterior damper path suits Broan AER110K best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Broan AER110K housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Broan AER110K acoustic and static metrics stand?

Compare Broan AER110K published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series AER110K / INVENT PD ID 4697334 (Qualified 2026-08-19)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (95.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Broan AER110K handle taller ceilings or walk-in tub steam?

Evaluate how Broan AER110K scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Broan AER110K
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 95 sq ft1 CFM/sq ft @ 95.5 CFM
Tall Bath (9-ft Ceiling)Up to 84 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 45 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.3 kWh/yr (~$1.49/yr)25.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2224.3 kWh/yr (~$35.89/yr)25.6 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Broan AER110K?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Amazon Basics B089R8S365 110 / 94.3 CFM 1.0 sones (Same) 4.4 CFM/W 4 in. diameter
HomeWerks Worldwide 7107-03HW 110 / 96 CFM 1.0 sones (Same) 4.1 CFM/W 4 in. diameter
Milano TY-110-E 110 / 94.5 CFM 1.0 sones (Same) 3.9 CFM/W 4 in. diameter
Milano TY-110-ESHL 110 / 94.2 CFM 1.0 sones (Same) 3.9 CFM/W 4 in. diameter
Milano TY-110-ESL 110 / 94.2 CFM 1.0 sones (Same) 3.9 CFM/W 4 in. diameter

Is Broan AER110K sized right for your shower or tub room?

Check whether Broan AER110K clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Who should not install Broan AER110K in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan AER110K for residential use.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 45 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Ideal fit: Moisture load fits 95.5 CFM net static output
  • Primary match: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Broan AER110K?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan AER110K.

What electrical efficiency and runtime kWh define Broan AER110K?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Broan AER110K pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AER110K's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan AER110K?

Broan AER110K features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan AER110K's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AER110K's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan AER110K satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan AER110K clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Broan AER110K undersized or poorly matched for a bath renovation?

Skip Broan AER110K if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Broan AER110K CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan AER110K registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does Broan AER110K sound output compare to noisy contractor-grade fans?

Rated at 1.0 sones, Broan AER110K operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories