Skip to main content
Grant Estimator

Broan AMM03RSS Exhaust Fan Specifications

ENERGY STAR PD #4510010 · Range Hood · Qualified 2025-09-05
Verified Specification Summary

The Broan AMM03RSS (RANGE HOOD) moves 130 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 4.2 CFM/W efficacy, sizing bathrooms up to 130 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AMM03RSS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
130 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.2 CFM/W (#774/1,145)
Static Retention
0.1" test only
Motor Draw
31.0 W (11.3 kWh/yr)
Duct & Tier
3.25 x 10 in. rectangular · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan AMM03RSS vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan AMM03RSS (EPA filing PD #4510010) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Free-discharge delivery reaches 130 CFM (#230 of 1,145 certified models) via a 3.25 x 10 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 3.25 x 10 in. rectangular housing before entering attic bays.

EPA filing PD #4510010 verifies AMM03RSS (series: RANGE HOOD) under Broan (207 listed models, qualified 2025-09-05). Lighting kit: Yes. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 31.0 watts, about 11.3 kWh/yr (~$1.81/yr at $0.16/kWh) for 1 hr/day shower timers or 271.6 kWh/yr (~$43.46/yr) continuously. Closest competing matches include Nutone QTN130LE1 (130.0 CFM) and Greenheck SP-B110ES (118.0 CFM).

How does duct geometry alter Broan AMM03RSS static pressure?

Smooth 3.25 x 10 in. rectangular galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Broan AMM03RSS?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan AMM03RSS alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series AMM03RSS / RANGE HOOD PD ID 4510010 (Qualified 2025-09-05)
Duct Connection 3.25 x 10 in. rectangular Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (130 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How much bathroom area can Broan AMM03RSS ventilate safely?

Sizing outputs below convert Broan AMM03RSS tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Broan AMM03RSS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 130 sq ft1 CFM/sq ft @ 130 CFM
Tall Bath (9-ft Ceiling)Up to 115 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 80 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)11.3 kWh/yr (~$1.81/yr)31.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2271.6 kWh/yr (~$43.46/yr)31.0 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Broan AMM03RSS closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Nutone QTN130LE1 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Greenheck SP-B110ES 118 / 100 CFM 1.5 sones 4.0 CFM/W 6 in. diameter
KORA SBF110N 119.2 / N/A CFM 1.6 sones 3.5 CFM/W 4 in. diameter
Broan QT130LE 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Broan QT130E 130 / 130.4 CFM 1.5 sones 4.7 CFM/W 6 in. diameter

Will Broan AMM03RSS clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Broan AMM03RSS satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Which bath layouts should avoid specifying Broan AMM03RSS?

Match Broan AMM03RSS directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 80 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Best for: Bathroom floor <= 130 sq ft with 8-ft ceilings (115 sq ft at 9-ft height)
  • Optimal use: Exterior run uses smooth rigid metal matched to 3.25 x 10 in. rectangular

What key rules and numbers govern Broan AMM03RSS?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan AMM03RSS.

What happens to Broan AMM03RSS CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Broan AMM03RSS moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 3.25 x 10 in. rectangular collar.

Where does Broan AMM03RSS sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Broan AMM03RSS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Broan AMM03RSS cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Broan AMM03RSS 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Broan AMM03RSS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AMM03RSS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan AMM03RSS?

Broan AMM03RSS features a 3.25 x 10 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan AMM03RSS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AMM03RSS's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Broan AMM03RSS ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan AMM03RSS covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Broan AMM03RSS run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan AMM03RSS.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories