Skip to main content
Grant Estimator

Broan-Nutone 6884E = 6884H with 1688EF Exhaust Fan Specifications

ENERGY STAR PD #3890961 · Bathroom/Utility Room · Qualified 2024-12-13
Verified Specification Summary

Certified by EPA ENERGY STAR, Broan-Nutone 6884E = 6884H with 1688EF delivers 50 CFM free-air (38.2 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 2.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 38 sq ft (8-ft height) or 33 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone 6884E = 6884H with 1688EF Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
50 / 38.2 CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
2.9 CFM/W (#1,132/1,145)
Static Retention
76.4% @ 0.25"
Motor Draw
17.2 W (6.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan-Nutone 6884E = 6884H with 1688EF vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 38.2 CFM at 0.25 in. w.g. (76.4% retention, 11.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places 6884E = 6884H with 1688EF (series: ECONOMY) (PD #3890961) among 48 Broan-Nutone entries qualified through 2024-12-13. Lighting kit: No. At 2.9 CFM/W (#1,132 of 1,145, tied with 13 other rated models at 2.9 CFM/W, 1.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.2 watts, about 6.3 kWh/yr (~$1.01/yr at $0.16/kWh) for 1 hr/day shower timers or 150.7 kWh/yr (~$24.11/yr) continuously. Closest competing matches include Broan 688ESL (50.0 CFM) and Cyclone CE50 (50.0 CFM).

How noisy is Broan-Nutone 6884E = 6884H with 1688EF compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Broan-Nutone 6884E = 6884H with 1688EF measures 2.0 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

Why does rigid 4 in. diameter ducting protect Broan-Nutone 6884E = 6884H with 1688EF airflow?

Connecting Broan-Nutone 6884E = 6884H with 1688EF through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Broan-Nutone 6884E = 6884H with 1688EF performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan-Nutone 6884E = 6884H with 1688EF lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan-Nutone (48 models) ENERGY STAR Certified Partner
Model Number & Series 6884E = 6884H with 1688EF / ECONOMY PD ID 3890961 (Qualified 2024-12-13)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (38.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Broan-Nutone 6884E = 6884H with 1688EF?

Calculated coverage metrics translate Broan-Nutone 6884E = 6884H with 1688EF airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Broan-Nutone 6884E = 6884H with 1688EF
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 38 sq ft1 CFM/sq ft @ 38.2 CFM
Tall Bath (9-ft Ceiling)Up to 33 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.3 kWh/yr (~$1.01/yr)17.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2150.7 kWh/yr (~$24.11/yr)17.2 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Broan-Nutone 6884E = 6884H with 1688EF?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan 688ESL 50 / 36.5 CFM 2.0 sones (Same) 3.0 CFM/W 3 in. diameter
Cyclone CE50 50 / 41 CFM 2.0 sones (Same) 3.1 CFM/W 3 in. diameter
Wintek 7140-50-PS 50 / 41 CFM 2.0 sones (Same) 3.1 CFM/W 3 in. diameter
Broan-Nutone 6884E = 6884EH with 1688EF 50 / 38.2 CFM 2.0 sones (Same) 2.9 CFM/W 4 in. diameter
Broan-Nutone 6884ES 50 / 38.2 CFM 2.0 sones (Same) 2.9 CFM/W 4 in. diameter

Does Broan-Nutone 6884E = 6884H with 1688EF match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan-Nutone 6884E = 6884H with 1688EF percentage capacity without sending data.

When does Broan-Nutone 6884E = 6884H with 1688EF fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan-Nutone 6884E = 6884H with 1688EF.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Recommended when: Supplementary continuous trickle ventilation
  • Target scenario: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Broan-Nutone 6884E = 6884H with 1688EF?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan-Nutone 6884E = 6884H with 1688EF.

Does running Broan-Nutone 6884E = 6884H with 1688EF continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Broan-Nutone 6884E = 6884H with 1688EF draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Broan-Nutone 6884E = 6884H with 1688EF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone 6884E = 6884H with 1688EF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan-Nutone 6884E = 6884H with 1688EF?

Broan-Nutone 6884E = 6884H with 1688EF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan-Nutone 6884E = 6884H with 1688EF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone 6884E = 6884H with 1688EF's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Broan-Nutone 6884E = 6884H with 1688EF code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone 6884E = 6884H with 1688EF clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Broan-Nutone 6884E = 6884H with 1688EF?

Do not force Broan-Nutone 6884E = 6884H with 1688EF into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Broan-Nutone 6884E = 6884H with 1688EF retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Broan-Nutone 6884E = 6884H with 1688EF produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will Broan-Nutone 6884E = 6884H with 1688EF disturb adjacent bedrooms during night use?

Acoustic measurement places Broan-Nutone 6884E = 6884H with 1688EF at 2.0 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories