In EPA dataset 8dv7-nngq, Broan-Nutone 6884ES tests at 50 CFM free discharge (38.2 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 2.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 38 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone 6884ES Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 38.2 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 2.9 CFM/W (#1,132/1,145)
- Static Retention
- 76.4% @ 0.25"
- Motor Draw
- 17.2 W (6.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan-Nutone 6884ES vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 50 CFM open-air to 38.2 CFM at 0.25 in. w.g. (76.4% retention, 11.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Broan-Nutone 6884ES (series: ECONOMY) under PD #4020873 (48 models registered, 2025-05-09). Lighting kit: No. At 2.9 CFM/W (#1,132 of 1,145, tied with 13 other rated models at 2.9 CFM/W, 1.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.2 watts, about 6.3 kWh/yr (~$1.01/yr at $0.16/kWh) for 1 hr/day shower timers or 150.7 kWh/yr (~$24.11/yr) continuously. Closest competing matches include Broan 688ESL (50.0 CFM) and Cyclone CE50 (50.0 CFM).
Does Broan-Nutone 6884ES fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Broan-Nutone 6884ES at 2.0 sones.
Why avoid unvented attic termination with Broan-Nutone 6884ES?
Under ASHRAE 62.2 best practice, Broan-Nutone 6884ES needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Broan-Nutone 6884ES?
Before cutting ceiling drywall or sizing attic transitions for Broan-Nutone 6884ES, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 6884ES / ECONOMY | PD ID 4020873 (Qualified 2025-05-09) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (38.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Broan-Nutone 6884ES?
Bathroom ventilation sizing below maps Broan-Nutone 6884ES motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 38 sq ft | 1 CFM/sq ft @ 38.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 33 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.3 kWh/yr (~$1.01/yr) | 17.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 150.7 kWh/yr (~$24.11/yr) | 17.2 W x 8,760 hrs / 1,000 |
What peer models sit nearest Broan-Nutone 6884ES in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan-Nutone 6884ES.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan 688ESL | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| Cyclone CE50 | 50 / 41 CFM | 2.0 sones (Same) | 3.1 CFM/W | 3 in. diameter |
| Wintek 7140-50-PS | 50 / 41 CFM | 2.0 sones (Same) | 3.1 CFM/W | 3 in. diameter |
| Broan-Nutone 6884E = 6884EH with 1688EF | 50 / 38.2 CFM | 2.0 sones (Same) | 2.9 CFM/W | 4 in. diameter |
| Broan-Nutone 6884E = 6884H with 1688EF | 50 / 38.2 CFM | 2.0 sones (Same) | 2.9 CFM/W | 4 in. diameter |
What percentage of room demand does Broan-Nutone 6884ES cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan-Nutone 6884ES tested delivery.
When does Broan-Nutone 6884ES fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan-Nutone 6884ES.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 38.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around 2.0 sones up to 38 sq ft
- Target scenario: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Broan-Nutone 6884ES?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan-Nutone 6884ES.
Will Broan-Nutone 6884ES disturb adjacent bedrooms during night use?
Acoustic measurement places Broan-Nutone 6884ES at 2.0 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Broan-Nutone 6884ES continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Broan-Nutone 6884ES draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Broan-Nutone 6884ES pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone 6884ES's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan-Nutone 6884ES?
Broan-Nutone 6884ES features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan-Nutone 6884ES's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone 6884ES's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Broan-Nutone 6884ES code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone 6884ES clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Broan-Nutone 6884ES?
Do not force Broan-Nutone 6884ES into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Broan-Nutone 6884ES retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Broan-Nutone 6884ES produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)