Rated for 50 CFM open-air (41 CFM at 0.25 in. w.g.), Cyclone CE50 registers #522 of 607 in quietness (2.0 sones) and delivers 3.1 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 41 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Cyclone CE50 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 41 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 3.1 CFM/W (#1,100/1,145)
- Static Retention
- 82.0% @ 0.25"
- Motor Draw
- 16.1 W (5.9 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does Cyclone CE50 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 50 CFM open-air to 41 CFM at 0.25 in. w.g. (82.0% retention, 5.7 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Cyclone CE50 (series: CE50) under PD #4518227 (17 models registered, 2025-12-05). Lighting kit: No. At 3.1 CFM/W (#1,100 of 1,145, below median tier among 1,145 rated models; more efficient than 3.6% of rated models, 1.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 16.1 watts, about 5.9 kWh/yr (~$0.94/yr at $0.16/kWh) for 1 hr/day shower timers or 141.0 kWh/yr (~$22.56/yr) continuously. Closest competing matches include Wintek 7140-50-PS (50.0 CFM) and Broan 688ESL (50.0 CFM).
How does Cyclone CE50 acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Cyclone CE50 (2.0 sones).
How do flex elbows choke Cyclone CE50 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3 in. diameter metal pipe keeps Cyclone CE50 moving full rated CFM.
Does Cyclone CE50 meet residential exhaust fan code specs?
Inspect Cyclone CE50 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Cyclone (17 models) | ENERGY STAR Certified Partner |
| Model Number & Series | CE50 / CE50 | PD ID 4518227 (Qualified 2025-12-05) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (41 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Cyclone CE50 airflow output?
Annual electricity figures and room square-footage ceilings below reflect Cyclone CE50 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 41 sq ft | 1 CFM/sq ft @ 41 CFM |
| Tall Bath (9-ft Ceiling) | Up to 36 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.9 kWh/yr (~$0.94/yr) | 16.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 141.0 kWh/yr (~$22.56/yr) | 16.1 W x 8,760 hrs / 1,000 |
Which competing models share Cyclone CE50 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Wintek 7140-50-PS | 50 / 41 CFM | 2.0 sones (Same) | 3.1 CFM/W | 3 in. diameter |
| Broan 688ESL | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| Broan-Nutone 688E | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| Broan-Nutone 688E = 1667EH with 1688EF | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| Broan-Nutone 688E = 1667H with 1688EF | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
How much airflow margin does Cyclone CE50 give your bath?
Run a quick local room-volume check for Cyclone CE50 by entering square footage and ceiling height to spot under-vented steam risks early.
When does Cyclone CE50 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Cyclone CE50.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 41 sq ft with 8-ft ceilings (36 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 3 in. diameter
What should homeowners verify first about Cyclone CE50?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Cyclone CE50.
Is Cyclone CE50 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Cyclone CE50 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Cyclone CE50?
Do not force Cyclone CE50 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Cyclone CE50 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Cyclone CE50 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 3 in. diameter metal duct transitions.
Will Cyclone CE50 disturb adjacent bedrooms during night use?
Acoustic measurement places Cyclone CE50 at 2.0 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Cyclone CE50 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Cyclone CE50 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Cyclone CE50 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Cyclone CE50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Cyclone CE50?
Cyclone CE50 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Cyclone CE50's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Cyclone CE50's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)