Rated for 50 CFM open-air (39.8 CFM at 0.25 in. w.g.), Greenlite G-VENT-9W registers #522 of 607 in quietness (2.0 sones) and delivers 7.4 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 39 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenlite G-VENT-9W Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 39.8 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 7.4 CFM/W (#392/1,145)
- Static Retention
- 79.6% @ 0.25"
- Motor Draw
- 6.8 W (2.5 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does Greenlite G-VENT-9W vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 50 CFM open-air to 39.8 CFM at 0.25 in. w.g. (79.6% retention, 8.1 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Greenlite's 1-unit lineup, G-VENT-9W (series: G-VENT) carries PD #4680274 dating to 2026-07-08. Lighting kit: No. At 7.4 CFM/W (#392 of 1,145, top 34.8% of 1,145 rated models, more efficient than 65.2% of rated models, 2.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.8 watts, about 2.5 kWh/yr (~$0.40/yr at $0.16/kWh) for 1 hr/day shower timers or 59.6 kWh/yr (~$9.54/yr) continuously. Closest competing matches include Ortech ODDE-50ES (50.0 CFM) and Revent RVSX50 (50.0 CFM).
How does Greenlite G-VENT-9W acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Greenlite G-VENT-9W (2.0 sones).
How do flex elbows choke Greenlite G-VENT-9W at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3 in. diameter metal pipe keeps Greenlite G-VENT-9W moving full rated CFM.
Does Greenlite G-VENT-9W meet residential exhaust fan code specs?
Inspect Greenlite G-VENT-9W mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Greenlite (1 model) | ENERGY STAR Certified Partner |
| Model Number & Series | G-VENT-9W / G-VENT | PD ID 4680274 (Qualified 2026-07-08) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (39.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Greenlite G-VENT-9W airflow output?
Annual electricity figures and room square-footage ceilings below reflect Greenlite G-VENT-9W tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 39 sq ft | 1 CFM/sq ft @ 39.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 35 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.5 kWh/yr (~$0.40/yr) | 6.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 59.6 kWh/yr (~$9.54/yr) | 6.8 W x 8,760 hrs / 1,000 |
Which competing models share Greenlite G-VENT-9W airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Ortech ODDE-50ES | 50 / 39.8 CFM | 2.0 sones (Same) | 7.4 CFM/W | 3 in. diameter |
| Revent RVSX50 | 50 / 52.2 CFM | 2.0 sones (Same) | 7.2 CFM/W | 3 in. diameter |
| Revent RVG50 | 50 / 51.5 CFM | 2.0 sones (Same) | 7.0 CFM/W | 3 in. diameter |
| Revent RVP50-ES | 50 / 51.5 CFM | 2.0 sones (Same) | 7.0 CFM/W | 3 in. diameter |
| Revent RVL70 | 70 / 72.3 CFM | 2.0 sones (Same) | 7.7 CFM/W | 4 in. diameter |
How much airflow margin does Greenlite G-VENT-9W give your bath?
Run a quick local room-volume check for Greenlite G-VENT-9W by entering square footage and ceiling height to spot under-vented steam risks early.
Who should not install Greenlite G-VENT-9W in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Greenlite G-VENT-9W for residential use.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 39 sq ft with 8-ft ceilings (35 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 3 in. diameter
What should homeowners verify first about Greenlite G-VENT-9W?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Greenlite G-VENT-9W.
When is Greenlite G-VENT-9W undersized or poorly matched for a bath renovation?
Skip Greenlite G-VENT-9W if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Greenlite G-VENT-9W CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Greenlite G-VENT-9W registers unlisted 0.25 in. w.g. backpressure figures, making rigid 3 in. diameter duct runs vital.
How does Greenlite G-VENT-9W sound output compare to noisy contractor-grade fans?
Rated at 2.0 sones, Greenlite G-VENT-9W produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Greenlite G-VENT-9W?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Greenlite G-VENT-9W pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenlite G-VENT-9W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Greenlite G-VENT-9W?
Greenlite G-VENT-9W features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Greenlite G-VENT-9W's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenlite G-VENT-9W's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Greenlite G-VENT-9W satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Greenlite G-VENT-9W clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)