Revent RVP50-ES Exhaust Fan Specifications

ENERGY STAR PD #3943315 · Bathroom/Utility Room · Qualified 2025-01-24
Verified Specification Summary

Rated for 50 CFM open-air (51.5 CFM at 0.25 in. w.g.), Revent RVP50-ES registers #522 of 607 in quietness (2.0 sones) and delivers 7.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 51 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVP50-ES Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 51.5 CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
7.0 CFM/W (#420/1,145)
Static Retention
103.0% @ 0.25"
Motor Draw
7.1 W (2.6 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Revent RVP50-ES vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 51.5 CFM out of 50 CFM (103.0% retention, 15.3 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #3943315 verifies RVP50-ES (series: ReVent) under Revent (40 listed models, qualified 2025-01-24). Lighting kit: No. At 7.0 CFM/W (#420 of 1,145, top 37.4% of 1,145 rated models, more efficient than 62.6% of rated models, 2.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.1 watts, about 2.6 kWh/yr (~$0.42/yr at $0.16/kWh) for 1 hr/day shower timers or 62.2 kWh/yr (~$9.95/yr) continuously. Closest competing matches include Greenlite G-VENT-9W (50.0 CFM) and Ortech ODDE-50ES (50.0 CFM).

How does Revent RVP50-ES acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Revent RVP50-ES (2.0 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

How do flex elbows choke Revent RVP50-ES at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3 in. diameter metal pipe keeps Revent RVP50-ES moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Revent RVP50-ES meet residential exhaust fan code specs?

Inspect Revent RVP50-ES mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Revent (40 models) ENERGY STAR Certified Partner
Model Number & Series RVP50-ES / ReVent PD ID 3943315 (Qualified 2025-01-24)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (51.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Revent RVP50-ES airflow output?

Annual electricity figures and room square-footage ceilings below reflect Revent RVP50-ES tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Revent RVP50-ES
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 51 sq ft1 CFM/sq ft @ 51.5 CFM
Tall Bath (9-ft Ceiling)Up to 45 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.6 kWh/yr (~$0.42/yr)7.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.262.2 kWh/yr (~$9.95/yr)7.1 W x 8,760 hrs / 1,000

Which competing models share Revent RVP50-ES airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Greenlite G-VENT-9W 50 / 39.8 CFM 2.0 sones (Same) 7.4 CFM/W 3 in. diameter
Ortech ODDE-50ES 50 / 39.8 CFM 2.0 sones (Same) 7.4 CFM/W 3 in. diameter
Revent RVG50 50 / 51.5 CFM 2.0 sones (Same) 7.0 CFM/W 3 in. diameter
Revent RVSX50 50 / 52.2 CFM 2.0 sones (Same) 7.2 CFM/W 3 in. diameter
Delta SLM70D 70 / 56.1 CFM Unpublished 7.0 CFM/W 3 in. diameter

How much airflow margin does Revent RVP50-ES give your bath?

Run a quick local room-volume check for Revent RVP50-ES by entering square footage and ceiling height to spot under-vented steam risks early.

Does Revent RVP50-ES suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Revent RVP50-ES for your remodel.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 51 sq ft with 8-ft ceilings (45 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 3 in. diameter

What should homeowners verify first about Revent RVP50-ES?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Revent RVP50-ES.

What acoustic sone tier does Revent RVP50-ES occupy in EPA filings?

With 2.0 sones at 0.1 in. w.g., Revent RVP50-ES produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Revent RVP50-ES add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Revent RVP50-ES averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Revent RVP50-ES pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVP50-ES's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Revent RVP50-ES?

Revent RVP50-ES features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Revent RVP50-ES's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVP50-ES's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Revent RVP50-ES pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Revent RVP50-ES easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Revent RVP50-ES in a bathroom remodel?

Avoid specifying Revent RVP50-ES in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Revent RVP50-ES airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Revent RVP50-ES achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3 in. diameter smooth galvanized pipe minimizes static pressure choke.