Revent RVG50 Exhaust Fan Specifications

ENERGY STAR PD #4611354 · Bathroom/Utility Room · Qualified 2026-04-22
Verified Specification Summary

In EPA dataset 8dv7-nngq, Revent RVG50 tests at 50 CFM free discharge (51.5 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 7.0 CFM/W efficacy, meeting residential IRC M1505 sizing up to 51 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVG50 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 51.5 CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
7.0 CFM/W (#420/1,145)
Static Retention
103.0% @ 0.25"
Motor Draw
7.1 W (2.6 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Revent RVG50 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 51.5 CFM out of 50 CFM (103.0% retention, 15.3 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Revent's 40-unit lineup, RVG50 (series: ReVent) carries PD #4611354 dating to 2026-04-22. Lighting kit: No. At 7.0 CFM/W (#420 of 1,145, top 37.4% of 1,145 rated models, more efficient than 62.6% of rated models, 2.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.1 watts, about 2.6 kWh/yr (~$0.42/yr at $0.16/kWh) for 1 hr/day shower timers or 62.2 kWh/yr (~$9.95/yr) continuously. Closest competing matches include Greenlite G-VENT-9W (50.0 CFM) and Ortech ODDE-50ES (50.0 CFM).

Does Revent RVG50 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Revent RVG50 at 2.0 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

Why avoid unvented attic termination with Revent RVG50?

Under ASHRAE 62.2 best practice, Revent RVG50 needs insulated 3 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Revent RVG50?

Before cutting ceiling drywall or sizing attic transitions for Revent RVG50, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Revent (40 models) ENERGY STAR Certified Partner
Model Number & Series RVG50 / ReVent PD ID 4611354 (Qualified 2026-04-22)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (51.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Revent RVG50?

Bathroom ventilation sizing below maps Revent RVG50 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Revent RVG50
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 51 sq ft1 CFM/sq ft @ 51.5 CFM
Tall Bath (9-ft Ceiling)Up to 45 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.6 kWh/yr (~$0.42/yr)7.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.262.2 kWh/yr (~$9.95/yr)7.1 W x 8,760 hrs / 1,000

What peer models sit nearest Revent RVG50 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Revent RVG50.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Greenlite G-VENT-9W 50 / 39.8 CFM 2.0 sones (Same) 7.4 CFM/W 3 in. diameter
Ortech ODDE-50ES 50 / 39.8 CFM 2.0 sones (Same) 7.4 CFM/W 3 in. diameter
Revent RVP50-ES 50 / 51.5 CFM 2.0 sones (Same) 7.0 CFM/W 3 in. diameter
Revent RVSX50 50 / 52.2 CFM 2.0 sones (Same) 7.2 CFM/W 3 in. diameter
Delta SLM70D 70 / 56.1 CFM Unpublished 7.0 CFM/W 3 in. diameter

What percentage of room demand does Revent RVG50 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Revent RVG50 tested delivery.

What plumbing or duct constraints rule out Revent RVG50?

Compare where Revent RVG50 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 51.5 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around 2.0 sones up to 51 sq ft
  • Suited to: Paired with rigid galvanized 3 in. diameter transition

Where do official rules set limits for Revent RVG50?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Revent RVG50.

Why might a contractor swap Revent RVG50 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Revent RVG50 lacks adequate reserve.

How does Revent RVG50 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Revent RVG50 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 3 in. diameter rigid metal ducting protects real exhaust.

Is Revent RVG50 quiet enough for a primary bedroom bathroom?

At 2.0 sones, Revent RVG50 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Revent RVG50 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Revent RVG50 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVG50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Revent RVG50?

Revent RVG50 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Revent RVG50's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVG50's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Revent RVG50 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Revent RVG50 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Sources