Tested under HVI protocols, the Ortech ODDE-50ES exhaust unit achieves 50 CFM at 0.1 in. w.g. (39.8 CFM at 0.25 in. w.g.), registers #522 of 607 in quietness (2.0 sones) and delivers 7.4 CFM/W efficacy, covering standard baths up to 39 sq ft on a 3 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODDE-50ES Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 39.8 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 7.4 CFM/W (#392/1,145)
- Static Retention
- 79.6% @ 0.25"
- Motor Draw
- 6.8 W (2.5 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does Ortech ODDE-50ES vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 50 CFM open-air to 39.8 CFM at 0.25 in. w.g. (79.6% retention, 8.1 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #4586469 verifies ODDE-50ES (series: ODDE) under Ortech (27 listed models, qualified 2026-02-04). Lighting kit: No. At 7.4 CFM/W (#392 of 1,145, top 34.8% of 1,145 rated models, more efficient than 65.2% of rated models, 2.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.8 watts, about 2.5 kWh/yr (~$0.40/yr at $0.16/kWh) for 1 hr/day shower timers or 59.6 kWh/yr (~$9.54/yr) continuously. Closest competing matches include Greenlite G-VENT-9W (50.0 CFM) and Revent RVSX50 (50.0 CFM).
Where do Ortech ODDE-50ES sones rank across EPA ENERGY STAR fans?
Comparing Ortech ODDE-50ES (2.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Ortech ODDE-50ES CFM output?
Short straight 3 in. diameter duct paths retain up to ~82% of open-air capacity on Ortech ODDE-50ES, preventing premature peeling paint and mold growth.
How does Ortech ODDE-50ES measure up on airflow and noise ratings?
Each row below breaks down Ortech ODDE-50ES certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Ortech (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ODDE-50ES / ODDE | PD ID 4586469 (Qualified 2026-02-04) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (39.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Ortech ODDE-50ES CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 39 sq ft | 1 CFM/sq ft @ 39.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 35 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.5 kWh/yr (~$0.40/yr) | 6.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 59.6 kWh/yr (~$9.54/yr) | 6.8 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Ortech ODDE-50ES?
Compare Ortech ODDE-50ES side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Greenlite G-VENT-9W | 50 / 39.8 CFM | 2.0 sones (Same) | 7.4 CFM/W | 3 in. diameter |
| Revent RVSX50 | 50 / 52.2 CFM | 2.0 sones (Same) | 7.2 CFM/W | 3 in. diameter |
| Revent RVG50 | 50 / 51.5 CFM | 2.0 sones (Same) | 7.0 CFM/W | 3 in. diameter |
| Revent RVP50-ES | 50 / 51.5 CFM | 2.0 sones (Same) | 7.0 CFM/W | 3 in. diameter |
| Revent RVL70 | 70 / 72.3 CFM | 2.0 sones (Same) | 7.7 CFM/W | 4 in. diameter |
Can you size Ortech ODDE-50ES for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Ortech ODDE-50ES verified capacity.
When does Ortech ODDE-50ES fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Ortech ODDE-50ES.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 39.8 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around 2.0 sones up to 39 sq ft
- Target scenario: Paired with rigid galvanized 3 in. diameter transition
How do federal and code standards apply to Ortech ODDE-50ES?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Ortech ODDE-50ES.
Which bathroom layouts should pick a larger blower than Ortech ODDE-50ES?
Do not force Ortech ODDE-50ES into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Ortech ODDE-50ES retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Ortech ODDE-50ES produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 3 in. diameter metal duct transitions.
Will Ortech ODDE-50ES disturb adjacent bedrooms during night use?
Acoustic measurement places Ortech ODDE-50ES at 2.0 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Ortech ODDE-50ES continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Ortech ODDE-50ES draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Ortech ODDE-50ES pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODDE-50ES's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Ortech ODDE-50ES?
Ortech ODDE-50ES features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Ortech ODDE-50ES's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODDE-50ES's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Ortech ODDE-50ES code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Ortech ODDE-50ES clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)