Certified by EPA ENERGY STAR, Broan-Nutone 688E = 1667EH with 1688EF delivers 50 CFM free-air (36.5 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 3.0 CFM/W efficacy, clearing residential IRC M1505 sizing up to 36 sq ft (8-ft height) or 32 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone 688E = 1667EH with 1688EF Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 36.5 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 3.0 CFM/W (#1,105/1,145)
- Static Retention
- 73.0% @ 0.25"
- Motor Draw
- 16.7 W (6.1 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does Broan-Nutone 688E = 1667EH with 1688EF vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 50 CFM open-air to 36.5 CFM at 0.25 in. w.g. (73.0% retention, 14.7 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places 688E = 1667EH with 1688EF (series: D-Can Energy Star Fans) (PD #3892114) among 48 Broan-Nutone entries qualified through 2024-12-20. Lighting kit: No. At 3.0 CFM/W (#1,105 of 1,145, below median tier among 1,145 rated models; more efficient than 1.2% of rated models, 1.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 16.7 watts, about 6.1 kWh/yr (~$0.98/yr at $0.16/kWh) for 1 hr/day shower timers or 146.3 kWh/yr (~$23.41/yr) continuously. Closest competing matches include Broan 688ESL (50.0 CFM) and Cyclone CE50 (50.0 CFM).
How noisy is Broan-Nutone 688E = 1667EH with 1688EF compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Broan-Nutone 688E = 1667EH with 1688EF measures 2.0 sones across the 1,145-model registry.
Why does rigid 3 in. diameter ducting protect Broan-Nutone 688E = 1667EH with 1688EF airflow?
Connecting Broan-Nutone 688E = 1667EH with 1688EF through rigid 3 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Broan-Nutone 688E = 1667EH with 1688EF performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan-Nutone 688E = 1667EH with 1688EF lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 688E = 1667EH with 1688EF / D-Can Energy Star Fans | PD ID 3892114 (Qualified 2024-12-20) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (36.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Broan-Nutone 688E = 1667EH with 1688EF?
Calculated coverage metrics translate Broan-Nutone 688E = 1667EH with 1688EF airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 36 sq ft | 1 CFM/sq ft @ 36.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 32 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.1 kWh/yr (~$0.98/yr) | 16.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 146.3 kWh/yr (~$23.41/yr) | 16.7 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Broan-Nutone 688E = 1667EH with 1688EF?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan 688ESL | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| Cyclone CE50 | 50 / 41 CFM | 2.0 sones (Same) | 3.1 CFM/W | 3 in. diameter |
| Wintek 7140-50-PS | 50 / 41 CFM | 2.0 sones (Same) | 3.1 CFM/W | 3 in. diameter |
| Broan-Nutone 688E | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| Broan-Nutone 688E = 1667H with 1688EF | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
Does Broan-Nutone 688E = 1667EH with 1688EF match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan-Nutone 688E = 1667EH with 1688EF percentage capacity without sending data.
When does Broan-Nutone 688E = 1667EH with 1688EF fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan-Nutone 688E = 1667EH with 1688EF.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Recommended when: Supplementary continuous trickle ventilation
- Target scenario: Collar pairs with 3 in. diameter duct straight outdoors
Which homeowner questions come up most for Broan-Nutone 688E = 1667EH with 1688EF?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan-Nutone 688E = 1667EH with 1688EF.
Does running Broan-Nutone 688E = 1667EH with 1688EF continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Broan-Nutone 688E = 1667EH with 1688EF draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Broan-Nutone 688E = 1667EH with 1688EF pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone 688E = 1667EH with 1688EF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan-Nutone 688E = 1667EH with 1688EF?
Broan-Nutone 688E = 1667EH with 1688EF features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan-Nutone 688E = 1667EH with 1688EF's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone 688E = 1667EH with 1688EF's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Broan-Nutone 688E = 1667EH with 1688EF code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone 688E = 1667EH with 1688EF clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Broan-Nutone 688E = 1667EH with 1688EF?
Do not force Broan-Nutone 688E = 1667EH with 1688EF into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Broan-Nutone 688E = 1667EH with 1688EF retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Broan-Nutone 688E = 1667EH with 1688EF produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 3 in. diameter metal duct transitions.
Will Broan-Nutone 688E = 1667EH with 1688EF disturb adjacent bedrooms during night use?
Acoustic measurement places Broan-Nutone 688E = 1667EH with 1688EF at 2.0 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)