Skip to main content
Grant Estimator

Broan-Nutone 688ES Exhaust Fan Specifications

ENERGY STAR PD #4020876 · Bathroom/Utility Room · Qualified 2025-05-09
Verified Specification Summary

In EPA dataset 8dv7-nngq, Broan-Nutone 688ES tests at 50 CFM free discharge (36.5 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 3.0 CFM/W efficacy, meeting residential IRC M1505 sizing up to 36 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone 688ES Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 36.5 CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
3.0 CFM/W (#1,105/1,145)
Static Retention
73.0% @ 0.25"
Motor Draw
16.7 W (6.1 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan-Nutone 688ES vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 36.5 CFM at 0.25 in. w.g. (73.0% retention, 14.7 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Broan-Nutone 688ES (series: ECONOMY) under PD #4020876 (48 models registered, 2025-05-09). Lighting kit: No. At 3.0 CFM/W (#1,105 of 1,145, below median tier among 1,145 rated models; more efficient than 1.2% of rated models, 1.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 16.7 watts, about 6.1 kWh/yr (~$0.98/yr at $0.16/kWh) for 1 hr/day shower timers or 146.3 kWh/yr (~$23.41/yr) continuously. Closest competing matches include Broan 688ESL (50.0 CFM) and Cyclone CE50 (50.0 CFM).

Does Broan-Nutone 688ES fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Broan-Nutone 688ES at 2.0 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

Why avoid unvented attic termination with Broan-Nutone 688ES?

Under ASHRAE 62.2 best practice, Broan-Nutone 688ES needs insulated 3 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Broan-Nutone 688ES?

Before cutting ceiling drywall or sizing attic transitions for Broan-Nutone 688ES, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan-Nutone (48 models) ENERGY STAR Certified Partner
Model Number & Series 688ES / ECONOMY PD ID 4020876 (Qualified 2025-05-09)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (36.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Broan-Nutone 688ES?

Bathroom ventilation sizing below maps Broan-Nutone 688ES motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Broan-Nutone 688ES
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 36 sq ft1 CFM/sq ft @ 36.5 CFM
Tall Bath (9-ft Ceiling)Up to 32 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.1 kWh/yr (~$0.98/yr)16.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2146.3 kWh/yr (~$23.41/yr)16.7 W x 8,760 hrs / 1,000

What peer models sit nearest Broan-Nutone 688ES in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan-Nutone 688ES.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan 688ESL 50 / 36.5 CFM 2.0 sones (Same) 3.0 CFM/W 3 in. diameter
Cyclone CE50 50 / 41 CFM 2.0 sones (Same) 3.1 CFM/W 3 in. diameter
Wintek 7140-50-PS 50 / 41 CFM 2.0 sones (Same) 3.1 CFM/W 3 in. diameter
Broan-Nutone 688E 50 / 36.5 CFM 2.0 sones (Same) 3.0 CFM/W 3 in. diameter
Broan-Nutone 688E = 1667EH with 1688EF 50 / 36.5 CFM 2.0 sones (Same) 3.0 CFM/W 3 in. diameter

What percentage of room demand does Broan-Nutone 688ES cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan-Nutone 688ES tested delivery.

Where should contractors skip Broan-Nutone 688ES on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan-Nutone 688ES carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 36.5 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Choose this if: Target comfort around 2.0 sones up to 36 sq ft
  • Works well for: Paired with rigid galvanized 3 in. diameter transition

Where do official rules set limits for Broan-Nutone 688ES?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan-Nutone 688ES.

How much power does Broan-Nutone 688ES consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Broan-Nutone 688ES draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Broan-Nutone 688ES pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone 688ES's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan-Nutone 688ES?

Broan-Nutone 688ES features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan-Nutone 688ES's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone 688ES's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Broan-Nutone 688ES score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone 688ES delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Broan-Nutone 688ES?

Rule out Broan-Nutone 688ES when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Broan-Nutone 688ES capacity?

Because static drag at 0.25 in. w.g. lowers Broan-Nutone 688ES from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 3 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Broan-Nutone 688ES compared with a standard 3.0 sone builder fan?

Tested at 2.0 sones, Broan-Nutone 688ES produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories