Skip to main content
Grant Estimator

Broan-Nutone 688ES = 1667H with 1688ESF Exhaust Fan Specifications

ENERGY STAR PD #4020874 · Bathroom/Utility Room · Qualified 2025-05-09
Verified Specification Summary

The Broan-Nutone 688ES = 1667H with 1688ESF (ECONOMY) moves 50 CFM at 0.1 in. w.g. (36.5 CFM at 0.25 in. w.g.), registers #522 of 607 in quietness (2.0 sones), and delivers 3.0 CFM/W efficacy, sizing bathrooms up to 36 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone 688ES = 1667H with 1688ESF Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
50 / 36.5 CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
3.0 CFM/W (#1,105/1,145)
Static Retention
73.0% @ 0.25"
Motor Draw
16.7 W (6.1 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan-Nutone 688ES = 1667H with 1688ESF vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 36.5 CFM at 0.25 in. w.g. (73.0% retention, 14.7 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places 688ES = 1667H with 1688ESF (series: ECONOMY) (PD #4020874) among 48 Broan-Nutone entries qualified through 2025-05-09. Lighting kit: No. At 3.0 CFM/W (#1,105 of 1,145, below median tier among 1,145 rated models; more efficient than 1.2% of rated models, 1.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 16.7 watts, about 6.1 kWh/yr (~$0.98/yr at $0.16/kWh) for 1 hr/day shower timers or 146.3 kWh/yr (~$23.41/yr) continuously. Closest competing matches include Broan 688ESL (50.0 CFM) and Cyclone CE50 (50.0 CFM).

Where does Broan-Nutone 688ES = 1667H with 1688ESF sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 2.0 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

How does duct geometry alter Broan-Nutone 688ES = 1667H with 1688ESF static pressure?

Smooth 3 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Broan-Nutone 688ES = 1667H with 1688ESF?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan-Nutone 688ES = 1667H with 1688ESF alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan-Nutone (48 models) ENERGY STAR Certified Partner
Model Number & Series 688ES = 1667H with 1688ESF / ECONOMY PD ID 4020874 (Qualified 2025-05-09)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (36.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Broan-Nutone 688ES = 1667H with 1688ESF ventilate safely?

Sizing outputs below convert Broan-Nutone 688ES = 1667H with 1688ESF tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Broan-Nutone 688ES = 1667H with 1688ESF
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 36 sq ft1 CFM/sq ft @ 36.5 CFM
Tall Bath (9-ft Ceiling)Up to 32 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.1 kWh/yr (~$0.98/yr)16.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2146.3 kWh/yr (~$23.41/yr)16.7 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Broan-Nutone 688ES = 1667H with 1688ESF closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan 688ESL 50 / 36.5 CFM 2.0 sones (Same) 3.0 CFM/W 3 in. diameter
Cyclone CE50 50 / 41 CFM 2.0 sones (Same) 3.1 CFM/W 3 in. diameter
Wintek 7140-50-PS 50 / 41 CFM 2.0 sones (Same) 3.1 CFM/W 3 in. diameter
Broan-Nutone 688E 50 / 36.5 CFM 2.0 sones (Same) 3.0 CFM/W 3 in. diameter
Broan-Nutone 688E = 1667EH with 1688EF 50 / 36.5 CFM 2.0 sones (Same) 3.0 CFM/W 3 in. diameter

Will Broan-Nutone 688ES = 1667H with 1688ESF clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Broan-Nutone 688ES = 1667H with 1688ESF satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Does Broan-Nutone 688ES = 1667H with 1688ESF suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan-Nutone 688ES = 1667H with 1688ESF for your remodel.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 36 sq ft with 8-ft ceilings (32 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 3 in. diameter

What key rules and numbers govern Broan-Nutone 688ES = 1667H with 1688ESF?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan-Nutone 688ES = 1667H with 1688ESF.

What acoustic sone tier does Broan-Nutone 688ES = 1667H with 1688ESF occupy in EPA filings?

With 2.0 sones at 0.1 in. w.g., Broan-Nutone 688ES = 1667H with 1688ESF produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Broan-Nutone 688ES = 1667H with 1688ESF add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan-Nutone 688ES = 1667H with 1688ESF averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Broan-Nutone 688ES = 1667H with 1688ESF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone 688ES = 1667H with 1688ESF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan-Nutone 688ES = 1667H with 1688ESF?

Broan-Nutone 688ES = 1667H with 1688ESF features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan-Nutone 688ES = 1667H with 1688ESF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone 688ES = 1667H with 1688ESF's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan-Nutone 688ES = 1667H with 1688ESF pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone 688ES = 1667H with 1688ESF easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Broan-Nutone 688ES = 1667H with 1688ESF in a bathroom remodel?

Avoid specifying Broan-Nutone 688ES = 1667H with 1688ESF in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Broan-Nutone 688ES = 1667H with 1688ESF airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan-Nutone 688ES = 1667H with 1688ESF achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3 in. diameter smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories