Skip to main content
Grant Estimator

Broan-Nutone 6964NE = 6884H with 1696NEF Exhaust Fan Specifications

ENERGY STAR PD #3890959 · Bathroom/Utility Room · Qualified 2024-12-13
Verified Specification Summary

Homeowners specifying Broan-Nutone 6964NE = 6884H with 1696NEF gain 50 CFM at 0.1 in. w.g. (38.2 CFM at 0.25 in. w.g.) where it registers #522 of 607 in quietness (2.0 sones) and delivers 2.9 CFM/W efficacy, venting bathrooms up to 38 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone 6964NE = 6884H with 1696NEF Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
50 / 38.2 CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
2.9 CFM/W (#1,132/1,145)
Static Retention
76.4% @ 0.25"
Motor Draw
17.2 W (6.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan-Nutone 6964NE = 6884H with 1696NEF vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 38.2 CFM at 0.25 in. w.g. (76.4% retention, 11.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Broan-Nutone registers 48 certified models, with SKU 6964NE = 6884H with 1696NEF (series: ECONOMY) (PD #3890959) certified since 2024-12-13. Lighting kit: No. At 2.9 CFM/W (#1,132 of 1,145, tied with 13 other rated models at 2.9 CFM/W, 1.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.2 watts, about 6.3 kWh/yr (~$1.01/yr at $0.16/kWh) for 1 hr/day shower timers or 150.7 kWh/yr (~$24.11/yr) continuously. Closest competing matches include Broan 688ESL (50.0 CFM) and Cyclone CE50 (50.0 CFM).

What acoustic percentile does Broan-Nutone 6964NE = 6884H with 1696NEF occupy among 1,145 bath blowers?

Inspect how Broan-Nutone 6964NE = 6884H with 1696NEF positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

Which exterior damper path suits Broan-Nutone 6964NE = 6884H with 1696NEF best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Broan-Nutone 6964NE = 6884H with 1696NEF housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Broan-Nutone 6964NE = 6884H with 1696NEF acoustic and static metrics stand?

Compare Broan-Nutone 6964NE = 6884H with 1696NEF published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan-Nutone (48 models) ENERGY STAR Certified Partner
Model Number & Series 6964NE = 6884H with 1696NEF / ECONOMY PD ID 3890959 (Qualified 2024-12-13)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (38.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Broan-Nutone 6964NE = 6884H with 1696NEF handle taller ceilings or walk-in tub steam?

Evaluate how Broan-Nutone 6964NE = 6884H with 1696NEF scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Broan-Nutone 6964NE = 6884H with 1696NEF
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 38 sq ft1 CFM/sq ft @ 38.2 CFM
Tall Bath (9-ft Ceiling)Up to 33 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.3 kWh/yr (~$1.01/yr)17.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2150.7 kWh/yr (~$24.11/yr)17.2 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Broan-Nutone 6964NE = 6884H with 1696NEF?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan 688ESL 50 / 36.5 CFM 2.0 sones (Same) 3.0 CFM/W 3 in. diameter
Cyclone CE50 50 / 41 CFM 2.0 sones (Same) 3.1 CFM/W 3 in. diameter
Wintek 7140-50-PS 50 / 41 CFM 2.0 sones (Same) 3.1 CFM/W 3 in. diameter
Broan-Nutone 6884E = 6884EH with 1688EF 50 / 38.2 CFM 2.0 sones (Same) 2.9 CFM/W 4 in. diameter
Broan-Nutone 6884E = 6884H with 1688EF 50 / 38.2 CFM 2.0 sones (Same) 2.9 CFM/W 4 in. diameter

Is Broan-Nutone 6964NE = 6884H with 1696NEF sized right for your shower or tub room?

Check whether Broan-Nutone 6964NE = 6884H with 1696NEF clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Does Broan-Nutone 6964NE = 6884H with 1696NEF suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan-Nutone 6964NE = 6884H with 1696NEF for your remodel.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Supplementary continuous trickle ventilation
  • Best application: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Broan-Nutone 6964NE = 6884H with 1696NEF?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan-Nutone 6964NE = 6884H with 1696NEF.

Does Broan-Nutone 6964NE = 6884H with 1696NEF pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone 6964NE = 6884H with 1696NEF easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Broan-Nutone 6964NE = 6884H with 1696NEF in a bathroom remodel?

Avoid specifying Broan-Nutone 6964NE = 6884H with 1696NEF in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Broan-Nutone 6964NE = 6884H with 1696NEF airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan-Nutone 6964NE = 6884H with 1696NEF achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Broan-Nutone 6964NE = 6884H with 1696NEF occupy in EPA filings?

With 2.0 sones at 0.1 in. w.g., Broan-Nutone 6964NE = 6884H with 1696NEF produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Broan-Nutone 6964NE = 6884H with 1696NEF add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan-Nutone 6964NE = 6884H with 1696NEF averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Broan-Nutone 6964NE = 6884H with 1696NEF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone 6964NE = 6884H with 1696NEF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan-Nutone 6964NE = 6884H with 1696NEF?

Broan-Nutone 6964NE = 6884H with 1696NEF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan-Nutone 6964NE = 6884H with 1696NEF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone 6964NE = 6884H with 1696NEF's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories