Broan-Nutone 6964NE = 6884EH with 1696NEF Exhaust Fan Specifications

ENERGY STAR PD #3890958 · Bathroom/Utility Room · Qualified 2024-12-13
Verified Specification Summary

Tested under HVI protocols, the Broan-Nutone 6964NE = 6884EH with 1696NEF exhaust unit achieves 50 CFM at 0.1 in. w.g. (38.2 CFM at 0.25 in. w.g.), registers #522 of 607 in quietness (2.0 sones) and delivers 2.9 CFM/W efficacy, covering standard baths up to 38 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone 6964NE = 6884EH with 1696NEF Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
50 / 38.2 CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
2.9 CFM/W (#1,132/1,145)
Static Retention
76.4% @ 0.25"
Motor Draw
17.2 W (6.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan-Nutone 6964NE = 6884EH with 1696NEF vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 38.2 CFM at 0.25 in. w.g. (76.4% retention, 11.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Broan-Nutone maintains 48 active ENERGY STAR blowers; 6964NE = 6884EH with 1696NEF (series: ECONOMY) (PD #3890958) gained qualification on 2024-12-13. Lighting kit: No. At 2.9 CFM/W (#1,132 of 1,145, tied with 13 other rated models at 2.9 CFM/W, 1.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.2 watts, about 6.3 kWh/yr (~$1.01/yr at $0.16/kWh) for 1 hr/day shower timers or 150.7 kWh/yr (~$24.11/yr) continuously. Closest competing matches include Broan 688ESL (50.0 CFM) and Cyclone CE50 (50.0 CFM).

Where do Broan-Nutone 6964NE = 6884EH with 1696NEF sones rank across EPA ENERGY STAR fans?

Comparing Broan-Nutone 6964NE = 6884EH with 1696NEF (2.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

What attic duct routing preserves Broan-Nutone 6964NE = 6884EH with 1696NEF CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Broan-Nutone 6964NE = 6884EH with 1696NEF, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Broan-Nutone 6964NE = 6884EH with 1696NEF measure up on airflow and noise ratings?

Each row below breaks down Broan-Nutone 6964NE = 6884EH with 1696NEF certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan-Nutone (48 models) ENERGY STAR Certified Partner
Model Number & Series 6964NE = 6884EH with 1696NEF / ECONOMY PD ID 3890958 (Qualified 2024-12-13)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (38.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Broan-Nutone 6964NE = 6884EH with 1696NEF CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan-Nutone 6964NE = 6884EH with 1696NEF
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 38 sq ft1 CFM/sq ft @ 38.2 CFM
Tall Bath (9-ft Ceiling)Up to 33 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.3 kWh/yr (~$1.01/yr)17.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2150.7 kWh/yr (~$24.11/yr)17.2 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Broan-Nutone 6964NE = 6884EH with 1696NEF?

Compare Broan-Nutone 6964NE = 6884EH with 1696NEF side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan 688ESL 50 / 36.5 CFM 2.0 sones (Same) 3.0 CFM/W 3 in. diameter
Cyclone CE50 50 / 41 CFM 2.0 sones (Same) 3.1 CFM/W 3 in. diameter
Wintek 7140-50-PS 50 / 41 CFM 2.0 sones (Same) 3.1 CFM/W 3 in. diameter
Broan-Nutone 6884E = 6884EH with 1688EF 50 / 38.2 CFM 2.0 sones (Same) 2.9 CFM/W 4 in. diameter
Broan-Nutone 6884E = 6884H with 1688EF 50 / 38.2 CFM 2.0 sones (Same) 2.9 CFM/W 4 in. diameter

Can you size Broan-Nutone 6964NE = 6884EH with 1696NEF for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan-Nutone 6964NE = 6884EH with 1696NEF verified capacity.

Does Broan-Nutone 6964NE = 6884EH with 1696NEF suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan-Nutone 6964NE = 6884EH with 1696NEF for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 38.2 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around 2.0 sones up to 38 sq ft
  • Best application: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Broan-Nutone 6964NE = 6884EH with 1696NEF?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan-Nutone 6964NE = 6884EH with 1696NEF.

Does duct resistance cut Broan-Nutone 6964NE = 6884EH with 1696NEF airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan-Nutone 6964NE = 6884EH with 1696NEF achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Broan-Nutone 6964NE = 6884EH with 1696NEF occupy in EPA filings?

With 2.0 sones at 0.1 in. w.g., Broan-Nutone 6964NE = 6884EH with 1696NEF produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Broan-Nutone 6964NE = 6884EH with 1696NEF add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan-Nutone 6964NE = 6884EH with 1696NEF averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Broan-Nutone 6964NE = 6884EH with 1696NEF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone 6964NE = 6884EH with 1696NEF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan-Nutone 6964NE = 6884EH with 1696NEF?

Broan-Nutone 6964NE = 6884EH with 1696NEF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan-Nutone 6964NE = 6884EH with 1696NEF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone 6964NE = 6884EH with 1696NEF's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan-Nutone 6964NE = 6884EH with 1696NEF pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone 6964NE = 6884EH with 1696NEF easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Broan-Nutone 6964NE = 6884EH with 1696NEF in a bathroom remodel?

Avoid specifying Broan-Nutone 6964NE = 6884EH with 1696NEF in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories