Rated for 50 CFM open-air (36.5 CFM at 0.25 in. w.g.), Broan-Nutone 696NE = 1667EH with 1696NEF registers #522 of 607 in quietness (2.0 sones) and delivers 3.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 36 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone 696NE = 1667EH with 1696NEF Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 36.5 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 3.0 CFM/W (#1,105/1,145)
- Static Retention
- 73.0% @ 0.25"
- Motor Draw
- 16.7 W (6.1 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does Broan-Nutone 696NE = 1667EH with 1696NEF vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 50 CFM open-air to 36.5 CFM at 0.25 in. w.g. (73.0% retention, 14.7 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #3892118 verifies 696NE = 1667EH with 1696NEF (series: D-Can Energy Star Fans) under Broan-Nutone (48 listed models, qualified 2024-12-20). Lighting kit: No. At 3.0 CFM/W (#1,105 of 1,145, below median tier among 1,145 rated models; more efficient than 1.2% of rated models, 1.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 16.7 watts, about 6.1 kWh/yr (~$0.98/yr at $0.16/kWh) for 1 hr/day shower timers or 146.3 kWh/yr (~$23.41/yr) continuously. Closest competing matches include Broan 688ESL (50.0 CFM) and Cyclone CE50 (50.0 CFM).
How does Broan-Nutone 696NE = 1667EH with 1696NEF acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan-Nutone 696NE = 1667EH with 1696NEF (2.0 sones).
How do flex elbows choke Broan-Nutone 696NE = 1667EH with 1696NEF at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3 in. diameter metal pipe keeps Broan-Nutone 696NE = 1667EH with 1696NEF moving full rated CFM.
Does Broan-Nutone 696NE = 1667EH with 1696NEF meet residential exhaust fan code specs?
Inspect Broan-Nutone 696NE = 1667EH with 1696NEF mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 696NE = 1667EH with 1696NEF / D-Can Energy Star Fans | PD ID 3892118 (Qualified 2024-12-20) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (36.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Broan-Nutone 696NE = 1667EH with 1696NEF airflow output?
Annual electricity figures and room square-footage ceilings below reflect Broan-Nutone 696NE = 1667EH with 1696NEF tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 36 sq ft | 1 CFM/sq ft @ 36.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 32 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.1 kWh/yr (~$0.98/yr) | 16.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 146.3 kWh/yr (~$23.41/yr) | 16.7 W x 8,760 hrs / 1,000 |
Which competing models share Broan-Nutone 696NE = 1667EH with 1696NEF airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan 688ESL | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| Cyclone CE50 | 50 / 41 CFM | 2.0 sones (Same) | 3.1 CFM/W | 3 in. diameter |
| Wintek 7140-50-PS | 50 / 41 CFM | 2.0 sones (Same) | 3.1 CFM/W | 3 in. diameter |
| Broan-Nutone 688E | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| Broan-Nutone 688E = 1667EH with 1688EF | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
How much airflow margin does Broan-Nutone 696NE = 1667EH with 1696NEF give your bath?
Run a quick local room-volume check for Broan-Nutone 696NE = 1667EH with 1696NEF by entering square footage and ceiling height to spot under-vented steam risks early.
Does Broan-Nutone 696NE = 1667EH with 1696NEF suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan-Nutone 696NE = 1667EH with 1696NEF for your remodel.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 36 sq ft with 8-ft ceilings (32 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 3 in. diameter
What should homeowners verify first about Broan-Nutone 696NE = 1667EH with 1696NEF?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan-Nutone 696NE = 1667EH with 1696NEF.
How many kWh per year does Broan-Nutone 696NE = 1667EH with 1696NEF add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Broan-Nutone 696NE = 1667EH with 1696NEF averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Broan-Nutone 696NE = 1667EH with 1696NEF pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone 696NE = 1667EH with 1696NEF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan-Nutone 696NE = 1667EH with 1696NEF?
Broan-Nutone 696NE = 1667EH with 1696NEF features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan-Nutone 696NE = 1667EH with 1696NEF's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone 696NE = 1667EH with 1696NEF's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Broan-Nutone 696NE = 1667EH with 1696NEF pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone 696NE = 1667EH with 1696NEF easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Broan-Nutone 696NE = 1667EH with 1696NEF in a bathroom remodel?
Avoid specifying Broan-Nutone 696NE = 1667EH with 1696NEF in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Broan-Nutone 696NE = 1667EH with 1696NEF airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan-Nutone 696NE = 1667EH with 1696NEF achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Broan-Nutone 696NE = 1667EH with 1696NEF occupy in EPA filings?
With 2.0 sones at 0.1 in. w.g., Broan-Nutone 696NE = 1667EH with 1696NEF produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)