Homeowners specifying Broan-Nutone 6884ES = 6884H with 1688ESF gain 50 CFM at 0.1 in. w.g. (38.2 CFM at 0.25 in. w.g.) where it registers #522 of 607 in quietness (2.0 sones) and delivers 2.9 CFM/W efficacy, venting bathrooms up to 38 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone 6884ES = 6884H with 1688ESF Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 38.2 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 2.9 CFM/W (#1,132/1,145)
- Static Retention
- 76.4% @ 0.25"
- Motor Draw
- 17.2 W (6.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan-Nutone 6884ES = 6884H with 1688ESF vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 50 CFM open-air to 38.2 CFM at 0.25 in. w.g. (76.4% retention, 11.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Broan-Nutone's 48-unit lineup, 6884ES = 6884H with 1688ESF (series: ECONOMY) carries PD #4020871 dating to 2025-05-09. Lighting kit: No. At 2.9 CFM/W (#1,132 of 1,145, tied with 13 other rated models at 2.9 CFM/W, 1.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.2 watts, about 6.3 kWh/yr (~$1.01/yr at $0.16/kWh) for 1 hr/day shower timers or 150.7 kWh/yr (~$24.11/yr) continuously. Closest competing matches include Broan 688ESL (50.0 CFM) and Cyclone CE50 (50.0 CFM).
What acoustic percentile does Broan-Nutone 6884ES = 6884H with 1688ESF occupy among 1,145 bath blowers?
Inspect how Broan-Nutone 6884ES = 6884H with 1688ESF positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Broan-Nutone 6884ES = 6884H with 1688ESF best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Broan-Nutone 6884ES = 6884H with 1688ESF housings.
Where do Broan-Nutone 6884ES = 6884H with 1688ESF acoustic and static metrics stand?
Compare Broan-Nutone 6884ES = 6884H with 1688ESF published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 6884ES = 6884H with 1688ESF / ECONOMY | PD ID 4020871 (Qualified 2025-05-09) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (38.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can Broan-Nutone 6884ES = 6884H with 1688ESF handle taller ceilings or walk-in tub steam?
Evaluate how Broan-Nutone 6884ES = 6884H with 1688ESF scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 38 sq ft | 1 CFM/sq ft @ 38.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 33 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.3 kWh/yr (~$1.01/yr) | 17.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 150.7 kWh/yr (~$24.11/yr) | 17.2 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Broan-Nutone 6884ES = 6884H with 1688ESF?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan 688ESL | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| Cyclone CE50 | 50 / 41 CFM | 2.0 sones (Same) | 3.1 CFM/W | 3 in. diameter |
| Wintek 7140-50-PS | 50 / 41 CFM | 2.0 sones (Same) | 3.1 CFM/W | 3 in. diameter |
| Broan-Nutone 6884E = 6884EH with 1688EF | 50 / 38.2 CFM | 2.0 sones (Same) | 2.9 CFM/W | 4 in. diameter |
| Broan-Nutone 6884E = 6884H with 1688EF | 50 / 38.2 CFM | 2.0 sones (Same) | 2.9 CFM/W | 4 in. diameter |
Is Broan-Nutone 6884ES = 6884H with 1688ESF sized right for your shower or tub room?
Check whether Broan-Nutone 6884ES = 6884H with 1688ESF clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Does Broan-Nutone 6884ES = 6884H with 1688ESF suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan-Nutone 6884ES = 6884H with 1688ESF for your remodel.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Strong scenario: Supplementary continuous trickle ventilation
- Best application: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Broan-Nutone 6884ES = 6884H with 1688ESF?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan-Nutone 6884ES = 6884H with 1688ESF.
How many kWh per year does Broan-Nutone 6884ES = 6884H with 1688ESF add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Broan-Nutone 6884ES = 6884H with 1688ESF averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Broan-Nutone 6884ES = 6884H with 1688ESF pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone 6884ES = 6884H with 1688ESF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan-Nutone 6884ES = 6884H with 1688ESF?
Broan-Nutone 6884ES = 6884H with 1688ESF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan-Nutone 6884ES = 6884H with 1688ESF's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone 6884ES = 6884H with 1688ESF's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Broan-Nutone 6884ES = 6884H with 1688ESF pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone 6884ES = 6884H with 1688ESF easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Broan-Nutone 6884ES = 6884H with 1688ESF in a bathroom remodel?
Avoid specifying Broan-Nutone 6884ES = 6884H with 1688ESF in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Broan-Nutone 6884ES = 6884H with 1688ESF airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan-Nutone 6884ES = 6884H with 1688ESF achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Broan-Nutone 6884ES = 6884H with 1688ESF occupy in EPA filings?
With 2.0 sones at 0.1 in. w.g., Broan-Nutone 6884ES = 6884H with 1688ESF produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)