Cyclone CT100 Exhaust Fan Specifications

ENERGY STAR PD #4480905 · Bathroom/Utility Room · Qualified 2025-06-20
Verified Specification Summary

Homeowners specifying Cyclone CT100 gain 100 CFM at 0.1 in. w.g. (92.2 CFM at 0.25 in. w.g.) where it registers #522 of 607 in quietness (2.0 sones) and delivers 3.9 CFM/W efficacy, venting bathrooms up to 92 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Cyclone CT100 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 92.2 CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
92.2% @ 0.25"
Motor Draw
25.6 W (9.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Cyclone CT100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 92.2 CFM out of 100 CFM (92.2% retention, 4.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Cyclone maintains 17 active ENERGY STAR blowers; CT100 (series: CT) (PD #4480905) gained qualification on 2025-06-20. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include ACIQ AP100 (100.0 CFM) and Air King FR100 (100.0 CFM).

What acoustic percentile does Cyclone CT100 occupy among 1,145 bath blowers?

Inspect how Cyclone CT100 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

Which exterior damper path suits Cyclone CT100 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Cyclone CT100 housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Cyclone CT100 acoustic and static metrics stand?

Compare Cyclone CT100 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Cyclone (17 models) ENERGY STAR Certified Partner
Model Number & Series CT100 / CT PD ID 4480905 (Qualified 2025-06-20)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (92.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Cyclone CT100 handle taller ceilings or walk-in tub steam?

Evaluate how Cyclone CT100 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Cyclone CT100
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 92 sq ft1 CFM/sq ft @ 92.2 CFM
Tall Bath (9-ft Ceiling)Up to 81 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 42 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.3 kWh/yr (~$1.49/yr)25.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2224.3 kWh/yr (~$35.89/yr)25.6 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Cyclone CT100?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
ACIQ AP100 100 / 92.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter
Air King FR100 100 / 82.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter
Anzzi EF-AZ107WH 100 / 92.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter
Anzzi EF-AZ108WH 100 / 92.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter
Aria QBV01000 100 / 92.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter

Is Cyclone CT100 sized right for your shower or tub room?

Check whether Cyclone CT100 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Which bath layouts should avoid specifying Cyclone CT100?

Match Cyclone CT100 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 42 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 92.2 CFM net static output
  • Optimal use: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Cyclone CT100?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Cyclone CT100.

What happens to Cyclone CT100 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Cyclone CT100 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Cyclone CT100 sit on acoustic comfort for senior homeowners?

Measuring 2.0 sones, Cyclone CT100 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Cyclone CT100 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Cyclone CT100 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Cyclone CT100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Cyclone CT100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Cyclone CT100?

Cyclone CT100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Cyclone CT100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Cyclone CT100's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Cyclone CT100 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Cyclone CT100 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Cyclone CT100 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Cyclone CT100.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories