Skip to main content
Grant Estimator

Air King FR100 Exhaust Fan Specifications

ENERGY STAR PD #4480283 · Bathroom/Utility Room · Qualified 2025-07-25
Verified Specification Summary

Certified by EPA ENERGY STAR, Air King FR100 delivers 100 CFM free-air (82.2 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 3.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 82 sq ft (8-ft height) or 73 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King FR100 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 82.2 CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
82.2% @ 0.25"
Motor Draw
25.6 W (9.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Air King FR100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 82.2 CFM at 0.25 in. w.g. (82.2% retention, 5.5 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Air King maintains 62 active ENERGY STAR blowers; FR100 (series: Air King) (PD #4480283) gained qualification on 2025-07-25. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include ACIQ AP100 (100.0 CFM) and Anzzi EF-AZ107WH (100.0 CFM).

How noisy is Air King FR100 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Air King FR100 measures 2.0 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

Why does rigid 4 in. diameter ducting protect Air King FR100 airflow?

Connecting Air King FR100 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Air King FR100 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Air King FR100 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Air King (62 models) ENERGY STAR Certified Partner
Model Number & Series FR100 / Air King PD ID 4480283 (Qualified 2025-07-25)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (82.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Air King FR100?

Calculated coverage metrics translate Air King FR100 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Air King FR100
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 82 sq ft1 CFM/sq ft @ 82.2 CFM
Tall Bath (9-ft Ceiling)Up to 73 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 32 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.3 kWh/yr (~$1.49/yr)25.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2224.3 kWh/yr (~$35.89/yr)25.6 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Air King FR100?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
ACIQ AP100 100 / 92.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter
Anzzi EF-AZ107WH 100 / 92.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter
Anzzi EF-AZ108WH 100 / 92.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter
Aria QBV01000 100 / 92.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter
Cyclone CT100 100 / 92.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter

Does Air King FR100 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Air King FR100 percentage capacity without sending data.

Which bath layouts should avoid specifying Air King FR100?

Match Air King FR100 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 32 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 82.2 CFM net static output
  • Optimal use: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Air King FR100?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Air King FR100.

Where does Air King FR100 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Air King FR100.

What happens to Air King FR100 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Air King FR100 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Air King FR100 sit on acoustic comfort for senior homeowners?

Measuring 2.0 sones, Air King FR100 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Air King FR100 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Air King FR100 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Air King FR100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King FR100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Air King FR100?

Air King FR100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Air King FR100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King FR100's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Air King FR100 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Air King FR100 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories