Homeowners specifying Air King LEDAK100H gain 100 CFM at 0.1 in. w.g. (83.3 CFM at 0.25 in. w.g.) where it registers #522 of 607 in quietness (2.0 sones) and delivers 3.8 CFM/W efficacy, venting bathrooms up to 83 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King LEDAK100H Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 83.3 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 3.8 CFM/W (#951/1,145)
- Static Retention
- 83.3% @ 0.25"
- Motor Draw
- 26.3 W (9.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Air King LEDAK100H vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 100 CFM open-air to 83.3 CFM at 0.25 in. w.g. (83.3% retention, 4.4 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Air King registers 62 certified models, with SKU LEDAK100H (series: Air King) (PD #2269999) certified since 2016-06-15. Lighting kit: Yes. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.3 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 230.4 kWh/yr (~$36.86/yr) continuously. Closest competing matches include Panasonic FV-0810RS1 (100.0 CFM) and Panasonic FV-0811RF1 (100.0 CFM).
What acoustic percentile does Air King LEDAK100H occupy among 1,145 bath blowers?
Inspect how Air King LEDAK100H positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Air King LEDAK100H best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Air King LEDAK100H housings.
Where do Air King LEDAK100H acoustic and static metrics stand?
Compare Air King LEDAK100H published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | LEDAK100H / Air King | PD ID 2269999 (Qualified 2016-06-15) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (83.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Can Air King LEDAK100H handle taller ceilings or walk-in tub steam?
Evaluate how Air King LEDAK100H scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 83 sq ft | 1 CFM/sq ft @ 83.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 74 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 33 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.6 kWh/yr (~$1.54/yr) | 26.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 230.4 kWh/yr (~$36.86/yr) | 26.3 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Air King LEDAK100H?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Panasonic FV-0810RS1 | 100 / 89 CFM | Unpublished | 3.8 CFM/W | 4 in. diameter |
| Panasonic FV-0811RF1 | 100 / 93.1 CFM | Unpublished | 3.8 CFM/W | 3 in. diameter |
| Panasonic Eco Solutions FV-0810RSL1 | 100 / 90 CFM | Unpublished | 3.7 CFM/W | 4 in. diameter |
| ACIQ AP100 | 100 / 92.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Anzzi EF-AZ107WH | 100 / 92.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
Is Air King LEDAK100H sized right for your shower or tub room?
Check whether Air King LEDAK100H clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Does Air King LEDAK100H suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Air King LEDAK100H for your remodel.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 33 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Strong scenario: Moisture load fits 83.3 CFM net static output
- Best application: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Air King LEDAK100H?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Air King LEDAK100H.
Who should NOT install Air King LEDAK100H in a bathroom remodel?
Avoid specifying Air King LEDAK100H in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Air King LEDAK100H airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Air King LEDAK100H achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Air King LEDAK100H occupy in EPA filings?
With 2.0 sones at 0.1 in. w.g., Air King LEDAK100H produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does Air King LEDAK100H add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Air King LEDAK100H averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Air King LEDAK100H pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King LEDAK100H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King LEDAK100H?
Air King LEDAK100H features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King LEDAK100H's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King LEDAK100H's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Air King LEDAK100H pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Air King LEDAK100H easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)