The Panasonic FV-0810RS1 (WhisperThin) moves 100 CFM at 0.1 in. w.g. (89 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 3.8 CFM/W efficacy, sizing bathrooms up to 89 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0810RS1 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 89 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 3.8 CFM/W (#951/1,145)
- Static Retention
- 89.0% @ 0.25"
- Motor Draw
- 26.3 W (9.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Panasonic FV-0810RS1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Panasonic FV-0810RS1 (EPA filing PD #2390261) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 89 CFM out of 100 CFM (89.0% retention, 1.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Panasonic maintains 92 active ENERGY STAR blowers; FV-0810RS1 (series: WhisperThin) (PD #2390261) gained qualification on 2022-01-07. Lighting kit: No. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.3 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 230.4 kWh/yr (~$36.86/yr) continuously. Closest competing matches include Hunter 90064A (100.0 CFM) and Hunter 90065A (100.0 CFM).
How does duct geometry alter Panasonic FV-0810RS1 static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Panasonic FV-0810RS1?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Panasonic FV-0810RS1 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic (92 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FV-0810RS1 / WhisperThin | PD ID 2390261 (Qualified 2022-01-07) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (89 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Panasonic FV-0810RS1 ventilate safely?
Sizing outputs below convert Panasonic FV-0810RS1 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 89 sq ft | 1 CFM/sq ft @ 89 CFM |
| Tall Bath (9-ft Ceiling) | Up to 79 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 39 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.6 kWh/yr (~$1.54/yr) | 26.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 230.4 kWh/yr (~$36.86/yr) | 26.3 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Panasonic FV-0810RS1 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Hunter 90064A | 100 / 89.6 CFM | 1.5 sones | 3.9 CFM/W | 4 in. diameter |
| Hunter 90065A | 100 / 89.6 CFM | 1.5 sones | 3.9 CFM/W | 4 in. diameter |
| Anzzi EF-AZ106MB | 100 / 92.8 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
| Anzzi EF-AZ106WH | 100 / 92.8 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
| Fantech SMPL100 (484302) | 100 / 91.2 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
Will Panasonic FV-0810RS1 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Panasonic FV-0810RS1 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Does Panasonic FV-0810RS1 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Panasonic FV-0810RS1 for your remodel.
Limitations & Who Should Skip
- Steam or walk-in tub room > 39 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 89 sq ft with 8-ft ceilings (79 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Panasonic FV-0810RS1?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Panasonic FV-0810RS1.
How many kWh per year does Panasonic FV-0810RS1 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Panasonic FV-0810RS1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Panasonic FV-0810RS1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0810RS1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic FV-0810RS1?
Panasonic FV-0810RS1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic FV-0810RS1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0810RS1's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Panasonic FV-0810RS1 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0810RS1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Panasonic FV-0810RS1 in a bathroom remodel?
Avoid specifying Panasonic FV-0810RS1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Panasonic FV-0810RS1 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Panasonic FV-0810RS1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Panasonic FV-0810RS1 occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., Panasonic FV-0810RS1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)